- smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.8.0-30-generic] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MK..59GSM (Adv. Format)
- Device Model: TOSHIBA MK1059GSM
- Serial Number: 71B2P124T
- LU WWN Device Id: 5 000039 3622035f4
- Firmware Version: GL001J
- User Capacity: 1,000,203,804,160 bytes [1.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Fri Sep 27 17:47:55 2013 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: FAILED!
- Drive failure expected in less than 24 hours. SAVE ALL DATA.
- See vendor-specific Attribute list for failed Attributes.
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 73) The previous self-test completed having
- a test element that failed and the test
- element that failed is not known.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 310) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 3146
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3220
- 5 Reallocated_Sector_Ct 0x0033 001 001 050 Pre-fail Always FAILING_NOW 16376
- 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 5233
- 10 Spin_Retry_Count 0x0033 164 100 030 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3023
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 13672
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 114
- 193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 28224
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Min/Max 11/46)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 613
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 16448
- 222 Loaded_Hours 0x0032 090 090 000 Old_age Always - 4290
- 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
- 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 266
- 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 3573 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 3573 occurred at disk power-on lifetime: 5174 hours (215 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 41 90 b8 b4 71 60 Error: ABRT at LBA = 0x0071b4b8 = 7451832
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 61 48 88 80 c8 7d 40 00 00:14:02.704 WRITE FPDMA QUEUED
- 61 48 80 c0 b4 7d 40 00 00:14:01.639 WRITE FPDMA QUEUED
- 61 48 78 c0 b3 7d 40 00 00:14:01.634 WRITE FPDMA QUEUED
- 61 48 70 00 b2 7d 40 00 00:14:01.628 WRITE FPDMA QUEUED
- 61 d8 68 d0 51 7d 40 00 00:14:01.621 WRITE FPDMA QUEUED
- Error 3572 occurred at disk power-on lifetime: 5165 hours (215 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 41 50 98 d0 04 60 Error: ABRT at LBA = 0x0004d098 = 315544
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 88 08 c8 fd a7 40 00 00:01:33.318 READ FPDMA QUEUED
- 60 70 00 50 f8 87 40 00 00:01:33.186 READ FPDMA QUEUED
- 61 b0 78 40 21 c4 40 00 00:01:33.092 WRITE FPDMA QUEUED
- 60 00 70 30 7f a8 40 00 00:01:33.092 READ FPDMA QUEUED
- 60 08 68 b8 64 8b 40 00 00:01:33.092 READ FPDMA QUEUED
- Error 3571 occurred at disk power-on lifetime: 5165 hours (215 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 30 00 01 01 00 00 00
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- aa aa aa aa aa aa aa ff 00:01:32.708 [RESERVED]
- 2f 00 01 10 00 00 a0 00 00:01:32.693 READ LOG EXT
- 60 20 70 30 f8 87 40 00 00:01:31.910 READ FPDMA QUEUED
- 61 18 68 20 2d 04 40 00 00:01:30.350 WRITE FPDMA QUEUED
- 61 60 60 98 f9 0d 40 00 00:01:30.350 WRITE FPDMA QUEUED
- Error 3570 occurred at disk power-on lifetime: 5165 hours (215 days + 5 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 01 10 f8 6b 04 60 Error: ABRT at LBA = 0x00046bf8 = 289784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 20 70 30 f8 87 40 00 00:01:31.910 READ FPDMA QUEUED
- 61 18 68 20 2d 04 40 00 00:01:30.350 WRITE FPDMA QUEUED
- 61 60 60 98 f9 0d 40 00 00:01:30.350 WRITE FPDMA QUEUED
- 61 08 58 10 1c 09 40 00 00:01:30.350 WRITE FPDMA QUEUED
- 60 00 50 e0 cf 2d 40 00 00:01:29.111 READ FPDMA QUEUED
- Error 3569 occurred at disk power-on lifetime: 5162 hours (215 days + 2 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 00 9f 28 04 e0 Error: ABRT at LBA = 0x0004289f = 272543
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ca 00 10 90 28 04 e0 00 00:01:19.041 WRITE DMA
- ef 10 02 00 00 00 a0 00 00:01:19.041 SET FEATURES [Reserved for Serial ATA]
- 27 00 00 00 00 00 e0 00 00:01:19.041 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 00:01:19.040 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 00:01:19.040 SET FEATURES [Set transfer mode]
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: unknown failure 90% 5233 0
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.