Advertisement
dotJason

IntelliChlor IC-40 Chatter

Jun 27th, 2016
62
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 1.35 KB | None | 0 0
  1. Short chlor frame (with active output percent). Every time the IC-40 toggles active/inactive these seem to change between zero and the setpoint. So when the setpint is 50% this will display either zero or 50 as it cycles. When idle it always generates a zero value. Sometimes I see byte B as a 14, other times an 11. Not sure what it means. Byte A is nearly always 50.
  2.  
  3. P C
  4. C H
  5. <hdr> A B T K <trm>
  6. 10 02 50 11 32 A5 10 03
  7. 10 02 50 0 0 62 10 03 -- 0%
  8. 10 02 50 11 32 A5 10 03 -- 50%
  9. 10 02 50 11 3C AF 10 03 -- 60%
  10. 10 02 50 11 47 BA 10 03 -- 71%
  11. 10 02 50 11 4B BE 10 03 -- 75%
  12. ++++++++++++++++++++++++++++++
  13.  
  14. Long chlor frame (with unknown values). These come less often and I haven't been able to decode them yet.
  15.  
  16. C
  17. H
  18. <hdr> A B C D K <trm>
  19. 10 02 0 12 4B 80 EF 10 03
  20. 10 02 0 12 4B 80 EF 10 03
  21. 10 02 0 12 4C 80 F0 10 03
  22. 10 02 0 12 4B 80 EF 10 03
  23. 10 02 0 1 0 0 13 10 03
  24. 10 02 0 12 4B 80 EF 10 03
  25.  
  26. ++++++++++++++++++++++++++++++
  27.  
  28. Sporadic broadcast (checksum does not calc out like other 10 02/10 03 frames). No idea BUT this is the response to a salinity check from the panel. You'd think the value would be in here but no luck so far.
  29.  
  30. 10 2 0 3 0 49 6E 74 65 6C 6C 69 63 68 6C 6F 72 2D 2D 34 30 BC 10 3