- Short chlor frame (with active output percent). Every time the IC-40 toggles active/inactive these seem to change between zero and the setpoint. So when the setpint is 50% this will display either zero or 50 as it cycles. When idle it always generates a zero value. Sometimes I see byte B as a 14, other times an 11. Not sure what it means. Byte A is nearly always 50.
- P C
- C H
- <hdr> A B T K <trm>
- 10 02 50 11 32 A5 10 03
- 10 02 50 0 0 62 10 03 -- 0%
- 10 02 50 11 32 A5 10 03 -- 50%
- 10 02 50 11 3C AF 10 03 -- 60%
- 10 02 50 11 47 BA 10 03 -- 71%
- 10 02 50 11 4B BE 10 03 -- 75%
- ++++++++++++++++++++++++++++++
- Long chlor frame (with unknown values). These come less often and I haven't been able to decode them yet.
- C
- H
- <hdr> A B C D K <trm>
- 10 02 0 12 4B 80 EF 10 03
- 10 02 0 12 4B 80 EF 10 03
- 10 02 0 12 4C 80 F0 10 03
- 10 02 0 12 4B 80 EF 10 03
- 10 02 0 1 0 0 13 10 03
- 10 02 0 12 4B 80 EF 10 03
- ++++++++++++++++++++++++++++++
- Sporadic broadcast (checksum does not calc out like other 10 02/10 03 frames). No idea BUT this is the response to a salinity check from the panel. You'd think the value would be in here but no luck so far.
- 10 2 0 3 0 49 6E 74 65 6C 6C 69 63 68 6C 6F 72 2D 2D 34 30 BC 10 3
- I n t e l l i c h l o r - - 4 0