- #smartctl -a
- smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.8.13-1-ARCH] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: KINGSTON SM2280S3G2120G
- Serial Number: -Hidden-
- Firmware Version: SAFM01.R
- User Capacity: 120,034,123,776 bytes [120 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: Solid State Device
- Form Factor: M.2
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Wed Jan 4 10:44:15 2017 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 30) seconds.
- Offline data collection
- capabilities: (0x79) SMART execute Offline immediate.
- No Auto Offline data collection support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 2) minutes.
- Conveyance self-test routine
- recommended polling time: ( 3) minutes.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
- 3 Spin_Up_Time 0x0007 100 100 050 Pre-fail Always - 0
- 5 Reallocated_Sector_Ct 0x0013 100 100 050 Pre-fail Always - 0
- 7 Unknown_SSD_Attribute 0x000b 100 100 050 Pre-fail Always - 0
- 8 Unknown_SSD_Attribute 0x0005 100 100 050 Pre-fail Offline - 0
- 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 3
- 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 22
- 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0
- 170 Unknown_Attribute 0x0003 100 100 010 Pre-fail Always - 157
- 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 1
- 175 Program_Fail_Count_Chip 0x0013 100 100 050 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0012 100 100 000 Old_age Always - 0
- 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 12
- 194 Temperature_Celsius 0x0023 061 057 030 Pre-fail Always - 39 (Min/Max 24/43)
- 196 Reallocated_Event_Count 0x0002 100 100 010 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
- 199 UDMA_CRC_Error_Count 0x000b 100 100 050 Pre-fail Always - 0
- 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0
- 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 100
- 233 Media_Wearout_Indicator 0x000b 100 100 000 Pre-fail Always - 17
- 240 Unknown_SSD_Attribute 0x0013 100 100 000 Pre-fail Always - 0
- 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 43
- 242 Total_LBAs_Read 0x0012 100 100 000 Old_age Always - 15
- 244 Unknown_Attribute 0x0002 100 100 000 Old_age Always - 0
- 245 Unknown_Attribute 0x0002 100 100 000 Old_age Always - 1
- 246 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 12224
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.