- smartctl -a /dev/sda
- smartctl version 5.38 [x86_64-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
- Home page is http://smartmontools.sourceforge.net/
- === START OF INFORMATION SECTION ===
- Device Model: WDC WD5000BPVT-00HXZT1
- Serial Number: WD-WX11A61X5787
- Firmware Version: 01.01A01
- User Capacity: 500,107,862,016 bytes
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Sat Aug 25 14:08:15 2012 EDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 121) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: (12360) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 123) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x7035) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 205 201 021 Pre-fail Always - 750
- 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1153
- 5 Reallocated_Sector_Ct 0x0033 165 165 140 Pre-fail Always - 297
- 7 Seek_Error_Rate 0x002e 194 194 000 Old_age Always - 349
- 9 Power_On_Hours 0x0032 095 095 000 Old_age Always - 3813
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1147
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 171
- 193 Load_Cycle_Count 0x0032 178 178 000 Old_age Always - 68424
- 194 Temperature_Celsius 0x0022 096 083 000 Old_age Always - 51
- 196 Reallocated_Event_Count 0x0032 199 199 000 Old_age Always - 1
- 197 Current_Pending_Sector 0x0032 001 001 000 Old_age Always - 65504
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- ATA Error Count: 42 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 42 occurred at disk power-on lifetime: 3813 hours (158 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 58 e0 ac a9 e9 Error: UNC 88 sectors at LBA = 0x09a9ace0 = 162114784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 58 cf ac a9 e9 08 00:24:47.132 READ DMA
- ef 10 02 00 00 00 a0 08 00:24:47.132 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 08 00:24:47.129 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:24:47.129 SET FEATURES [Set transfer mode]
- Error 41 occurred at disk power-on lifetime: 3813 hours (158 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 58 e0 ac a9 e9 Error: UNC 88 sectors at LBA = 0x09a9ace0 = 162114784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 58 cf ac a9 e9 08 00:24:42.687 READ DMA
- ef 10 02 00 00 00 a0 08 00:24:42.687 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 08 00:24:42.684 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:24:42.684 SET FEATURES [Set transfer mode]
- Error 40 occurred at disk power-on lifetime: 3813 hours (158 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 58 e0 ac a9 e9 Error: UNC 88 sectors at LBA = 0x09a9ace0 = 162114784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 58 cf ac a9 e9 08 00:24:39.196 READ DMA
- ef 10 02 00 00 00 a0 08 00:24:39.196 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 08 00:24:39.193 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:24:39.193 SET FEATURES [Set transfer mode]
- Error 39 occurred at disk power-on lifetime: 3813 hours (158 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 58 e0 ac a9 e9 Error: UNC 88 sectors at LBA = 0x09a9ace0 = 162114784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 58 cf ac a9 e9 08 00:24:34.756 READ DMA
- ef 10 02 00 00 00 a0 08 00:24:34.756 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 08 00:24:34.753 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:24:34.753 SET FEATURES [Set transfer mode]
- Error 38 occurred at disk power-on lifetime: 3813 hours (158 days + 21 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 58 e0 ac a9 e9 Error: UNC 88 sectors at LBA = 0x09a9ace0 = 162114784
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- c8 00 58 cf ac a9 e9 08 00:24:32.013 READ DMA
- ef 10 02 00 00 00 a0 08 00:24:32.013 SET FEATURES [Reserved for Serial ATA]
- ec 00 00 00 00 00 a0 08 00:24:32.010 IDENTIFY DEVICE
- ef 03 46 00 00 00 a0 08 00:24:32.010 SET FEATURES [Set transfer mode]
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: read failure 90% 3813 161940560
- # 2 Extended offline Completed without error 00% 3345 -
- # 3 Extended offline Completed without error 00% 3132 -
- # 4 Conveyance offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.