Advertisement
Guest User

Untitled

a guest
May 9th, 2014
20
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 5.35 KB | None | 0 0
  1. [root@* ~]# smartctl -a /dev/sda
  2. smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-371.3.1.el5.028stab110.1] (local build)
  3. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Device Model: TOSHIBA DT01ACA200
  7. Serial Number: Z3AYMBBKS
  8. LU WWN Device Id: 5 000039 ff3e9a678
  9. Firmware Version: MX4OABB0
  10. User Capacity: 2,000,398,934,016 bytes [2.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Device is: Not in smartctl database [for details use: -P showall]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 4
  15. Local Time is: Fri May 9 08:37:16 2014 EDT
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x84) Offline data collection activity
  24. was suspended by an interrupting command from host.
  25. Auto Offline Data Collection: Enabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (13961) seconds.
  31. Offline data collection
  32. capabilities: (0x5b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 1) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 233) minutes.
  49. SCT capabilities: (0x003d) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
  58. 2 Throughput_Performance 0x0005 140 140 054 Pre-fail Offline - 68
  59. 3 Spin_Up_Time 0x0007 100 100 024 Pre-fail Always - 0
  60. 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 3
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
  63. 8 Seek_Time_Performance 0x0005 124 124 020 Pre-fail Offline - 33
  64. 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 1498
  65. 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3
  67. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 12
  68. 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 12
  69. 194 Temperature_Celsius 0x0002 214 214 000 Old_age Always - 28 (Min/Max 21/30)
  70. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  71. 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
  72. 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
  73. 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  80. # 1 Short offline Completed without error 00% 874 -
  81. # 2 Short offline Completed without error 00% 871 -
  82. # 3 Short offline Completed without error 00% 837 -
  83.  
  84. SMART Selective self-test log data structure revision number 1
  85. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  86. 1 0 0 Not_testing
  87. 2 0 0 Not_testing
  88. 3 0 0 Not_testing
  89. 4 0 0 Not_testing
  90. 5 0 0 Not_testing
  91. Selective self-test flags (0x0):
  92. After scanning selected spans, do NOT read-scan remainder of disk.
  93. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment
Advertisement