- root@lhs:/home/libesz# smartctl -a /dev/sda
- smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-4-686-pae] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar Green
- Device Model: WDC WD10EACS-00D6B0
- Serial Number: WD-WCAU42611814
- LU WWN Device Id: 5 0014ee 20204e435
- Firmware Version: 01.01A01
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Mon Jan 20 19:38:51 2014 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (23400) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 181 159 021 Pre-fail Always - 5950
- 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1426
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 051 Old_age Always - 0
- 9 Power_On_Hours 0x0032 050 050 000 Old_age Always - 36802
- 10 Spin_Retry_Count 0x0032 100 100 051 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 051 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1422
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 257
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 1426
- 194 Temperature_Celsius 0x0022 114 091 000 Old_age Always - 36
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 529
- 200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@lhs:/home/libesz# smartctl -a /dev/sdb
- smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-4-686-pae] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar Green
- Device Model: WDC WD10EACS-00D6B1
- Serial Number: WD-WCAU45308475
- LU WWN Device Id: 5 0014ee 1ac24863e
- Firmware Version: 01.01A01
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Mon Jan 20 19:39:18 2014 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (22800) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x303f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 181 160 021 Pre-fail Always - 5933
- 4 Start_Stop_Count 0x0032 098 098 000 Old_age Always - 2279
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 052 052 000 Old_age Always - 35581
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 098 098 000 Old_age Always - 2274
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 420
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 2279
- 194 Temperature_Celsius 0x0022 115 089 000 Old_age Always - 35
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 2
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 18390
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.