- smartctl -a /dev/ada2
- smartctl 6.3 2014-07-26 r3976 [FreeBSD 9.3-RELEASE-p5 amd64] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Red (AF)
- Device Model: WDC WD40EFRX-68WT0N0
- Serial Number: WD-WCC4E6PVSZ1D
- LU WWN Device Id: 5 0014ee 20b4a1538
- Firmware Version: 82.00A82
- User Capacity: 4,000,787,030,016 bytes [4.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
- Local Time is: Fri Jan 16 11:00:56 2015 CST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (52680) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 527) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x703d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 179 176 021 Pre-fail Always - 8041
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 16
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 214
- 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 16
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 9
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 26
- 194 Temperature_Celsius 0x0022 122 119 000 Old_age Always - 30
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 213 -
- # 2 Short offline Completed without error 00% 212 -
- # 3 Short offline Completed without error 00% 211 -
- # 4 Extended offline Completed without error 00% 211 -
- # 5 Short offline Interrupted (host reset) 90% 199 -
- # 6 Short offline Completed without error 00% 198 -
- # 7 Short offline Completed without error 00% 197 -
- # 8 Short offline Completed without error 00% 196 -
- # 9 Short offline Completed without error 00% 195 -
- #10 Short offline Completed without error 00% 194 -
- #11 Short offline Completed without error 00% 193 -
- #12 Short offline Completed without error 00% 193 -
- #13 Short offline Completed without error 00% 191 -
- #14 Short offline Completed without error 00% 190 -
- #15 Short offline Completed without error 00% 189 -
- #16 Short offline Completed without error 00% 188 -
- #17 Short offline Completed without error 00% 187 -
- #18 Short offline Completed without error 00% 186 -
- #19 Short offline Completed without error 00% 185 -
- #20 Short offline Completed without error 00% 184 -
- #21 Short offline Completed without error 00% 183 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Add Comment