  1. smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.8-1-ARCH] (local build)
  2. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Caviar Blue (SATA 6Gb/s)
  6. Device Model: WDC WD5000AAKX-001CA0
  7. Serial Number: WD-WCAYUFJ42450
  8. LU WWN Device Id: 5 0014ee 206680053
  9. Firmware Version: 15.01H15
  10. User Capacity: 500,107,862,016 bytes [500 GB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: ATA8-ACS (minor revision not indicated)
  14. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  15. Local Time is: Fri Apr 11 02:13:53 2014 MSK
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x82) Offline data collection activity
  24. was completed without error.
  25. Auto Offline Data Collection: Enabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: ( 8160) seconds.
  31. Offline data collection
  32. capabilities: (0x7b) SMART execute Offline immediate.
  33. Auto Offline data collection on/off support.
  34. Suspend Offline collection upon new
  35. command.
  36. Offline surface scan supported.
  37. Self-test supported.
  38. Conveyance Self-test supported.
  39. Selective Self-test supported.
  40. SMART capabilities: (0x0003) Saves SMART data before entering
  41. power-saving mode.
  42. Supports SMART auto save timer.
  43. Error logging capability: (0x01) Error logging supported.
  44. General Purpose Logging supported.
  45. Short self-test routine
  46. recommended polling time: ( 2) minutes.
  47. Extended self-test routine
  48. recommended polling time: ( 83) minutes.
  49. Conveyance self-test routine
  50. recommended polling time: ( 5) minutes.
  51. SCT capabilities: (0x3037) SCT Status supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 37
  59. 3 Spin_Up_Time 0x0027 141 140 021 Pre-fail Always - 3925
  60. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 685
  61. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
  63. 9 Power_On_Hours 0x0032 093 093 000 Old_age Always - 5150
  64. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  65. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 683
  67. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 24
  68. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 660
  69. 194 Temperature_Celsius 0x0022 105 102 000 Old_age Always - 38
  70. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  71. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  72. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
  73. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  74. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  75.  
  76. SMART Error Log Version: 1
  77. ATA Error Count: 9 (device log contains only the most recent five errors)
  78. CR = Command Register [HEX]
  79. FR = Features Register [HEX]
  80. SC = Sector Count Register [HEX]
  81. SN = Sector Number Register [HEX]
  82. CL = Cylinder Low Register [HEX]
  83. CH = Cylinder High Register [HEX]
  84. DH = Device/Head Register [HEX]
  85. DC = Device Command Register [HEX]
  86. ER = Error register [HEX]
  87. ST = Status register [HEX]
  88. Powered_Up_Time is measured from power on, and printed as
  89. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  90. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  91.  
  92. Error 9 occurred at disk power-on lifetime: 4128 hours (172 days + 0 hours)
  93. When the command that caused the error occurred, the device was active or idle.
  94.  
  95. After command completion occurred, registers were:
  96. ER ST SC SN CL CH DH
  97. -- -- -- -- -- -- --
  98. 40 51 08 4b 32 7a e7 Error: UNC 8 sectors at LBA = 0x077a324b = 125448779
  99.  
  100. Commands leading to the command that caused the error were:
  101. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  102. -- -- -- -- -- -- -- -- ---------------- --------------------
  103. c8 00 08 47 32 7a e7 08 01:33:28.005 READ DMA
  104. ec 00 00 00 00 00 a0 08 01:33:27.999 IDENTIFY DEVICE
  105. ef 03 46 00 00 00 a0 08 01:33:27.999 SET FEATURES [Set transfer mode]
  106.  
  107. Error 8 occurred at disk power-on lifetime: 4128 hours (172 days + 0 hours)
  108. When the command that caused the error occurred, the device was active or idle.
  109.  
  110. After command completion occurred, registers were:
  111. ER ST SC SN CL CH DH
  112. -- -- -- -- -- -- --
  113. 40 51 10 4b 32 7a e7 Error: UNC 16 sectors at LBA = 0x077a324b = 125448779
  114.  
  115. Commands leading to the command that caused the error were:
  116. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  117. -- -- -- -- -- -- -- -- ---------------- --------------------
  118. c8 00 10 47 32 7a e7 08 01:33:26.357 READ DMA
  119. c8 00 10 87 75 7c e7 08 01:33:26.356 READ DMA
  120. c8 00 20 67 75 7c e7 08 01:33:26.342 READ DMA
  121. c8 00 10 a7 14 11 e0 08 01:33:26.342 READ DMA
  122. c8 00 20 87 14 11 e0 08 01:33:26.336 READ DMA
  123.  
  124. Error 7 occurred at disk power-on lifetime: 4128 hours (172 days + 0 hours)
  125. When the command that caused the error occurred, the device was active or idle.
  126.  
  127. After command completion occurred, registers were:
  128. ER ST SC SN CL CH DH
  129. -- -- -- -- -- -- --
  130. 40 51 08 4b 32 7a e7 Error: UNC 8 sectors at LBA = 0x077a324b = 125448779
  131.  
  132. Commands leading to the command that caused the error were:
  133. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  134. -- -- -- -- -- -- -- -- ---------------- --------------------
  135. c8 00 08 47 32 7a e7 08 01:31:49.104 READ DMA
  136. b0 da 00 00 4f c2 00 08 01:30:37.622 SMART RETURN STATUS
  137. b0 d0 01 00 4f c2 00 08 01:30:37.618 SMART READ DATA
  138. b0 d1 01 00 4f c2 00 08 01:30:37.613 SMART READ ATTRIBUTE THRESHOLDS [OBS-4]
  139. e5 00 00 00 00 00 00 08 01:30:37.613 CHECK POWER MODE
  140.  
  141. Error 6 occurred at disk power-on lifetime: 4128 hours (172 days + 0 hours)
  142. When the command that caused the error occurred, the device was active or idle.
  143.  
  144. After command completion occurred, registers were:
  145. ER ST SC SN CL CH DH
  146. -- -- -- -- -- -- --
  147. 40 51 08 4b 32 7a e7 Error: UNC 8 sectors at LBA = 0x077a324b = 125448779
  148.  
  149. Commands leading to the command that caused the error were:
  150. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  151. -- -- -- -- -- -- -- -- ---------------- --------------------
  152. c8 00 08 47 32 7a e7 08 01:29:51.827 READ DMA
  153. c8 00 00 e7 32 7a e7 08 01:29:51.823 READ DMA
  154. c8 00 08 5f 24 61 e0 08 01:29:51.823 READ DMA
  155. c8 00 08 77 24 61 e0 08 01:29:51.823 READ DMA
  156.  
  157. Error 5 occurred at disk power-on lifetime: 4128 hours (172 days + 0 hours)
  158. When the command that caused the error occurred, the device was active or idle.
  159.  
  160. After command completion occurred, registers were:
  161. ER ST SC SN CL CH DH
  162. -- -- -- -- -- -- --
  163. 40 51 00 4b 32 7a e7 Error: UNC at LBA = 0x077a324b = 125448779
  164.  
  165. Commands leading to the command that caused the error were:
  166. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  167. -- -- -- -- -- -- -- -- ---------------- --------------------
  168. c8 00 00 e7 31 7a e7 08 01:29:50.178 READ DMA
  169. c8 00 08 7f 24 61 e0 08 01:29:50.177 READ DMA
  170. c8 00 80 67 31 7a e7 08 01:29:50.177 READ DMA
  171. c8 00 40 27 31 7a e7 08 01:29:50.177 READ DMA
  172. c8 00 20 07 31 7a e7 08 01:29:50.176 READ DMA
  173.  
  174. SMART Self-test log structure revision number 1
  175. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  176. # 1 Short offline Completed without error 00% 4411 -
  177. # 2 Short offline Completed without error 00% 4186 -
  178. # 3 Short offline Completed without error 00% 4142 -
  179. # 4 Conveyance offline Completed: read failure 90% 4126 125448779
  180. # 5 Short offline Completed: read failure 90% 4126 125448779
  181. # 6 Short offline Completed: read failure 90% 4126 125448779
  182. # 7 Short offline Completed: read failure 90% 4126 125448779
  183.  
  184. SMART Selective self-test log data structure revision number 1
  185. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  186. 1 0 0 Not_testing
  187. 2 0 0 Not_testing
  188. 3 0 0 Not_testing
  189. 4 0 0 Not_testing
  190. 5 0 0 Not_testing
  191. Selective self-test flags (0x0):
  192. After scanning selected spans, do NOT read-scan remainder of disk.
  193. If Selective self-test is pending on power-up, resume after 0 minute delay.