  1. LibreNMS Discovery
  2. Version info:
  3. Commit SHA: eedd8e3c9a2ea57a34e14f3f5c099087b94dba3d
  4. DB Schema: 152
  5. PHP: 7.0.8-0ubuntu0.16.04.3
  6. MySQL: 10.0.28-MariaDB-0ubuntu0.16.04.1
  7. RRDTool: 1.5.5
  8. SNMP: NET-SNMP 5.7.3
  9. DEBUG!
  10. SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1]
  11. SQL[SELECT revision FROM `dbSchema`]
  12. DB Schema already up to date.
  13. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'zywall.dc.novaware.nl' ORDER BY device_id DESC]
  14. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '2']
  15. zywall.dc.novaware.nl 2 zywall (zyxel)
  16. Modules status: Global+ OS Device
  17. #### Load disco module os ####
  18. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
  19. ZyWALL USG 300
  20.  
  21. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
  22. .*.4.1.890.1.6
  23.  
  24. | ZyWALL USG 300 | .1.3.6.1.4.1.890.1.6 |
  25. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ENTITY-MIB::entPhysicalDescr.1]
  26. No Such Object available on this agent at this OID
  27.  
  28. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqn -m FORTINET-FORTISWITCH-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 fsSysVersion.0]
  29. .*.4.1.123*.1.0 No Such Object available on this agent at this OID
  30.  
  31. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.39165.1.6.0]
  32. No Such Object available on this agent at this OID
  33.  
  34. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 SML-MIB::product-Name.0]
  35. No Such Object available on this agent at this OID
  36.  
  37. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.674.10895.3000.1.2.100.1.0]
  38. No Such Object available on this agent at this OID
  39.  
  40. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ENTITY-MIB::entPhysicalMfgName.1]
  41. No Such Object available on this agent at this OID
  42.  
  43.  
  44. >> Runtime for discovery module 'os': 0.1660 seconds
  45. #### Unload disco module os ####
  46.  
  47. Modules status: Global+ OS Device
  48. #### Load disco module ports ####
  49. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ifDescr]
  50. ifDescr.1 = lo
  51. ifDescr.2 = eth_base
  52. ifDescr.3 = doll
  53. ifDescr.4 = sit0
  54. ifDescr.5 = gre0
  55. ifDescr.6 = eth0
  56. ifDescr.7 = eth1
  57. ifDescr.8 = eth2
  58. ifDescr.9 = eth3
  59. ifDescr.10 = eth4
  60. ifDescr.11 = eth5
  61. ifDescr.12 = eth6
  62. ifDescr.13 = tunnel0
  63.  
  64. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ifName]
  65. ifName = No Such Object available on this agent at this OID
  66.  
  67. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ifType]
  68. ifType.1 = softwareLoopback
  69. ifType.2 = ethernetCsmacd
  70. ifType.3 = ethernetCsmacd
  71. ifType.4 = tunnel
  72. ifType.5 = tunnel
  73. ifType.6 = ethernetCsmacd
  74. ifType.7 = ethernetCsmacd
  75. ifType.8 = ethernetCsmacd
  76. ifType.9 = ethernetCsmacd
  77. ifType.10 = ethernetCsmacd
  78. ifType.11 = ethernetCsmacd
  79. ifType.12 = ethernetCsmacd
  80. ifType.13 = tunnel
  81.  
  82. Array
  83. (
  84. [1] => Array
  85. (
  86. [ifDescr] => lo
  87. [ifType] => softwareLoopback
  88. )
  89.  
  90. [2] => Array
  91. (
  92. [ifDescr] => eth_base
  93. [ifType] => ethernetCsmacd
  94. )
  95.  
  96. [3] => Array
  97. (
  98. [ifDescr] => doll
  99. [ifType] => ethernetCsmacd
  100. )
  101.  
  102. [4] => Array
  103. (
  104. [ifDescr] => sit0
  105. [ifType] => tunnel
  106. )
  107.  
  108. [5] => Array
  109. (
  110. [ifDescr] => gre0
  111. [ifType] => tunnel
  112. )
  113.  
  114. [6] => Array
  115. (
  116. [ifDescr] => eth0
  117. [ifType] => ethernetCsmacd
  118. )
  119.  
  120. [7] => Array
  121. (
  122. [ifDescr] => eth1
  123. [ifType] => ethernetCsmacd
  124. )
  125.  
  126. [8] => Array
  127. (
  128. [ifDescr] => eth2
  129. [ifType] => ethernetCsmacd
  130. )
  131.  
  132. [9] => Array
  133. (
  134. [ifDescr] => eth3
  135. [ifType] => ethernetCsmacd
  136. )
  137.  
  138. [10] => Array
  139. (
  140. [ifDescr] => eth4
  141. [ifType] => ethernetCsmacd
  142. )
  143.  
  144. [11] => Array
  145. (
  146. [ifDescr] => eth5
  147. [ifType] => ethernetCsmacd
  148. )
  149.  
  150. [12] => Array
  151. (
  152. [ifDescr] => eth6
  153. [ifType] => ethernetCsmacd
  154. )
  155.  
  156. [13] => Array
  157. (
  158. [ifDescr] => tunnel0
  159. [ifType] => tunnel
  160. )
  161.  
  162. )
  163. SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
  164. SQL[SELECT * FROM `ports` WHERE `device_id` = '2' ORDER BY port_id]
  165. .............
  166.  
  167. >> Runtime for discovery module 'ports': 2.2680 seconds
  168. #### Unload disco module ports ####
  169.  
  170. Modules status: Global+ OS Device
  171. #### Load disco module ports-stack ####
  172. SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '2']
  173. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus]
  174.  
  175.  
  176.  
  177. >> Runtime for discovery module 'ports-stack': 0.0190 seconds
  178. #### Unload disco module ports-stack ####
  179.  
  180. Modules status: Global+ OS Device
  181. #### Load disco module entity-physical ####
  182.  
  183. Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry]
  184. entPhysicalEntry = No Such Object available on this agent at this OID
  185.  
  186. entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier]
  187. entAliasMappingIdentifier = No Such Object available on this agent at this OID
  188.  
  189.  
  190. SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '2']
  191.  
  192. >> Runtime for discovery module 'entity-physical': 0.0700 seconds
  193. #### Unload disco module entity-physical ####
  194.  
  195. Modules status: Global+ OS Device
  196. #### Load disco module processors ####
  197. Including: /opt/librenms/includes/discovery/processors/adtran-aos.inc.php
  198. Including: /opt/librenms/includes/discovery/processors/aen.inc.php
  199. Including: /opt/librenms/includes/discovery/processors/aos-device.inc.php
  200. Including: /opt/librenms/includes/discovery/processors/avaya-ers.inc.php
  201. Including: /opt/librenms/includes/discovery/processors/avaya-vsp.inc.php
  202. Including: /opt/librenms/includes/discovery/processors/binos.inc.php
  203. Including: /opt/librenms/includes/discovery/processors/binox.inc.php
  204. Including: /opt/librenms/includes/discovery/processors/calix.inc.php
  205. Including: /opt/librenms/includes/discovery/processors/cambium.inc.php
  206. Including: /opt/librenms/includes/discovery/processors/ciscosb.inc.php
  207. Including: /opt/librenms/includes/discovery/processors/datacom.inc.php
  208. Including: /opt/librenms/includes/discovery/processors/dnos.inc.php
  209. Including: /opt/librenms/includes/discovery/processors/dsm.inc.php
  210. Including: /opt/librenms/includes/discovery/processors/edgeswitch.inc.php
  211. Including: /opt/librenms/includes/discovery/processors/extreme.inc.php
  212. Including: /opt/librenms/includes/discovery/processors/fiberhome.inc.php
  213. Including: /opt/librenms/includes/discovery/processors/fortigate.inc.php
  214. Including: /opt/librenms/includes/discovery/processors/fortiswitch.inc.php
  215. Including: /opt/librenms/includes/discovery/processors/hpblmos.inc.php
  216. Including: /opt/librenms/includes/discovery/processors/hrdevice.inc.php
  217. hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrDevice]
  218. hrDevice = No Such Object available on this agent at this OID
  219.  
  220. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad]
  221. hrProcessorLoad = No Such Object available on this agent at this OID
  222.  
  223. Including: /opt/librenms/includes/discovery/processors/infinity.inc.php
  224. Including: /opt/librenms/includes/discovery/processors/ios.inc.php
  225. Including: /opt/librenms/includes/discovery/processors/ironware.inc.php
  226. Including: /opt/librenms/includes/discovery/processors/junos.inc.php
  227. Including: /opt/librenms/includes/discovery/processors/junose.inc.php
  228. Including: /opt/librenms/includes/discovery/processors/netonix.inc.php
  229. Including: /opt/librenms/includes/discovery/processors/netscaler.inc.php
  230. Including: /opt/librenms/includes/discovery/processors/nos.inc.php
  231. Including: /opt/librenms/includes/discovery/processors/pbn.inc.php
  232. Including: /opt/librenms/includes/discovery/processors/powerconnect.inc.php
  233. Including: /opt/librenms/includes/discovery/processors/procurve.inc.php
  234. Including: /opt/librenms/includes/discovery/processors/pulse.inc.php
  235. Including: /opt/librenms/includes/discovery/processors/radlan.inc.php
  236. Including: /opt/librenms/includes/discovery/processors/screenos.inc.php
  237. Including: /opt/librenms/includes/discovery/processors/serveriron.inc.php
  238. Including: /opt/librenms/includes/discovery/processors/sonicwall.inc.php
  239. Including: /opt/librenms/includes/discovery/processors/unifi.inc.php
  240. Including: /opt/librenms/includes/discovery/processors/viprinux.inc.php
  241. Including: /opt/librenms/includes/discovery/processors/vrp.inc.php
  242. Including: /opt/librenms/includes/discovery/processors/zywall.inc.php
  243. Zywall Processors: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OQUvs -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.890.1.6.22.1.1.0]
  244. 0
  245.  
  246. Discover Processor: .1.3.6.1.4.1.890.1.6.22.1.1.0, 0, zywall, Processor, 1, 0, ,
  247. SQL[SELECT COUNT(processor_id) FROM `processors` WHERE `processor_index` = '0' AND `device_id` = '2' AND `processor_type` = 'zywall']
  248. .SQL[UPDATE `processors` set `processor_descr` ='Processor',`processor_oid` ='.1.3.6.1.4.1.890.1.6.22.1.1.0',`processor_usage` ='0',`processor_precision` ='1' WHERE `device_id`='2' AND `processor_index`='0' AND `processor_type`='zywall']
  249. SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '2' AND `processor_type` != 'ucd-old']
  250. Array
  251. (
  252. [zywall] => Array
  253. (
  254. [0] => 1
  255. )
  256.  
  257. )
  258. SQL[SELECT * FROM `processors` WHERE `device_id` = '2']
  259. 0 -> zywall
  260.  
  261.  
  262. >> Runtime for discovery module 'processors': 1.2210 seconds
  263. #### Unload disco module processors ####
  264.  
  265. Modules status: Global+ OS Device
  266. #### Load disco module mempools ####
  267. Including: /opt/librenms/includes/discovery/mempools/adtran-aos.inc.php
  268. Including: /opt/librenms/includes/discovery/mempools/aos-device.inc.php
  269. Including: /opt/librenms/includes/discovery/mempools/avaya-ers.inc.php
  270. Including: /opt/librenms/includes/discovery/mempools/avaya-vsp.inc.php
  271. Including: /opt/librenms/includes/discovery/mempools/binos.inc.php
  272. Including: /opt/librenms/includes/discovery/mempools/binox.inc.php
  273. Including: /opt/librenms/includes/discovery/mempools/cemp.inc.php
  274. Including: /opt/librenms/includes/discovery/mempools/ciscowlc.inc.php
  275. Including: /opt/librenms/includes/discovery/mempools/cmp.inc.php
  276. SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '2' AND `mempool_type` = 'cemp']
  277. Including: /opt/librenms/includes/discovery/mempools/dnos.inc.php
  278. Including: /opt/librenms/includes/discovery/mempools/edgeswitch.inc.php
  279. Including: /opt/librenms/includes/discovery/mempools/extreme.inc.php
  280. Including: /opt/librenms/includes/discovery/mempools/fiberhome.inc.php
  281. Including: /opt/librenms/includes/discovery/mempools/fortigate.inc.php
  282. Including: /opt/librenms/includes/discovery/mempools/fortiswitch.inc.php
  283. Including: /opt/librenms/includes/discovery/mempools/hp-procurve.inc.php
  284. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs/hp:/opt/librenms/mibs udp:HOSTNAME:161 hpLocal]
  285. hpLocalMem = No Such Object available on this agent at this OID
  286.  
  287. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs/hp:/opt/librenms/mibs udp:HOSTNAME:161 hpGlobal]
  288. hpGlobalMem = No Such Object available on this agent at this OID
  289.  
  290. Including: /opt/librenms/includes/discovery/mempools/hpblmos.inc.php
  291. Including: /opt/librenms/includes/discovery/mempools/hrstorage.inc.php
  292. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry]
  293. hrStorageEntry = No Such Object available on this agent at this OID
  294.  
  295. Including: /opt/librenms/includes/discovery/mempools/infinity.inc.php
  296. Including: /opt/librenms/includes/discovery/mempools/ironware-dyn.inc.php
  297. Including: /opt/librenms/includes/discovery/mempools/junos.inc.php
  298. Including: /opt/librenms/includes/discovery/mempools/netonix.inc.php
  299. Including: /opt/librenms/includes/discovery/mempools/netscaler.inc.php
  300. Including: /opt/librenms/includes/discovery/mempools/nos.inc.php
  301. Including: /opt/librenms/includes/discovery/mempools/nxos.inc.php
  302. Including: /opt/librenms/includes/discovery/mempools/pbn.inc.php
  303. Including: /opt/librenms/includes/discovery/mempools/powerconnect-cpu.inc.php
  304. Including: /opt/librenms/includes/discovery/mempools/pulse.inc.php
  305. Including: /opt/librenms/includes/discovery/mempools/screenos.inc.php
  306. Including: /opt/librenms/includes/discovery/mempools/serveriron.inc.php
  307. Including: /opt/librenms/includes/discovery/mempools/sonicwall.inc.php
  308. Including: /opt/librenms/includes/discovery/mempools/unifi.inc.php
  309. Including: /opt/librenms/includes/discovery/mempools/vrp.inc.php
  310. Including: /opt/librenms/includes/discovery/mempools/zywall.inc.php
  311. ZywallSNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.890.1.6.22.1.2.0]
  312. 54
  313.  
  314. Discover Mempool: 0, zywall, Memory, 1, ,
  315. SQL[SELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '0' AND `device_id` = '2' AND `mempool_type` = 'zywall']
  316. .SQL[UPDATE `mempools` set `mempool_descr` ='Memory' WHERE device_id='2' AND mempool_index='0' AND mempool_type='zywall']
  317. Array
  318. (
  319. [zywall] => Array
  320. (
  321. [0] => 1
  322. )
  323.  
  324. )
  325. SQL[SELECT * FROM `mempools` WHERE `device_id` = '2']
  326. 0 -> zywall
  327.  
  328.  
  329. >> Runtime for discovery module 'mempools': 10.8700 seconds
  330. #### Unload disco module mempools ####
  331.  
  332. Modules status: Global+ OS Device
  333. #### Load disco module cisco-vrf-lite ####
  334. SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '2' ]
  335.  
  336. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds
  337. #### Unload disco module cisco-vrf-lite ####
  338.  
  339. Modules status: Global+ OS Device
  340. #### Load disco module ipv4-addresses ####
  341. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex]
  342. ipAdEntIfIndex.* 7
  343. ipAdEntIfIndex.* 8
  344. ipAdEntIfIndex.* 1
  345. ipAdEntIfIndex.* 11
  346. ipAdEntIfIndex.* 12
  347. ipAdEntIfIndex.* 6
  348. ipAdEntIfIndex.* 10
  349.  
  350. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.46.249.34.197]
  351. *
  352.  
  353. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '7']
  354. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '7']
  355. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '46.249.34.192/28']
  356. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '46.249.34.192/28']
  357. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '46.249.34.192/28']
  358. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '46.249.34.197' AND `ipv4_prefixlen` = '28' AND `port_id` = '9' ]
  359. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '46.249.34.197' AND `ipv4_prefixlen` = '28' AND `port_id` = '9']
  360. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.46.249.34.198]
  361. *
  362.  
  363. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '8']
  364. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '8']
  365. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '46.249.34.192/28']
  366. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '46.249.34.192/28']
  367. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '46.249.34.192/28']
  368. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '46.249.34.198' AND `ipv4_prefixlen` = '28' AND `port_id` = '10' ]
  369. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '46.249.34.198' AND `ipv4_prefixlen` = '28' AND `port_id` = '10']
  370. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1]
  371. *
  372.  
  373. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '1']
  374. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '1']
  375. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
  376. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.0/8']
  377. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
  378. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '3' ]
  379. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '3']
  380. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.25.24.1]
  381. *
  382.  
  383. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '11']
  384. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '11']
  385. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.25.24.0/21']
  386. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.25.24.0/21']
  387. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.25.24.0/21']
  388. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.25.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '13' ]
  389. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '172.25.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '13']
  390. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.26.24.1]
  391. *
  392.  
  393. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '12']
  394. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '12']
  395. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.26.24.0/21']
  396. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.26.24.0/21']
  397. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.26.24.0/21']
  398. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.26.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '14' ]
  399. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '172.26.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '14']
  400. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.27.26.1]
  401. *
  402.  
  403. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '6']
  404. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '6']
  405. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.27.24.0/21']
  406. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.27.24.0/21']
  407. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.27.24.0/21']
  408. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.27.26.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '8' ]
  409. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '172.27.26.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '8']
  410. .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.28.24.1]
  411. *
  412.  
  413. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '2' AND `ifIndex` = '10']
  414. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '10']
  415. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.28.24.0/21']
  416. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.28.24.0/21']
  417. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.28.24.0/21']
  418. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.28.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '12' ]
  419. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE ipv4_address` = '172.28.24.1' AND `ipv4_prefixlen` = '21' AND `port_id` = '12']
  420. .SQL[SELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '2' AND A.port_id = I.port_id]
  421.  
  422.  
  423. >> Runtime for discovery module 'ipv4-addresses': 0.2100 seconds
  424. #### Unload disco module ipv4-addresses ####
  425.  
  426. Modules status: Global+ OS Device
  427. #### Load disco module ipv6-addresses ####
  428. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
  429. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  430.  
  431. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength]
  432. .*.*.8.1.2 No Such Object available on this agent at this OID
  433.  
  434. SQL[SELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '2' AND A.port_id = I.port_id']
  435.  
  436.  
  437. >> Runtime for discovery module 'ipv6-addresses': 3.9450 seconds
  438. #### Unload disco module ipv6-addresses ####
  439.  
  440. Modules status: Global- OS Device Module [ route ] disabled globally.
  441.  
  442. Modules status: Global+ OS Device
  443. #### Load disco module sensors ####
  444. Pre-cache: Including: /opt/librenms/includes/discovery/sensors/pre-cache/comware.inc.php
  445. Including: /opt/librenms/includes/discovery/sensors/pre-cache/datacom.inc.php
  446. Including: /opt/librenms/includes/discovery/sensors/pre-cache/junos.inc.php
  447. Including: /opt/librenms/includes/discovery/sensors/pre-cache/pbn.inc.php
  448. Including: /opt/librenms/includes/discovery/sensors/pre-cache/poweralert.inc.php
  449.  
  450. ENTITY-SENSOR: Caching OIDs: entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType]
  451. entPhySensorType = No Such Object available on this agent at this OID
  452.  
  453. entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale]
  454. entPhySensorScale = No Such Object available on this agent at this OID
  455.  
  456. entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision]
  457. entPhySensorPrecision = No Such Object available on this agent at this OID
  458.  
  459. entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue]
  460. entPhySensorValue = No Such Object available on this agent at this OID
  461.  
  462.  
  463. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '2' AND `attrib_type` = 'ipmi_hostname' ]
  464. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'ipmi']
  465. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'ipmi']
  466. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'ipmi']
  467. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'ipmi']
  468. Temperatures: Including: /opt/librenms/includes/discovery/sensors/temperatures/aen.inc.php
  469. Including: /opt/librenms/includes/discovery/sensors/temperatures/akcp.inc.php
  470. Including: /opt/librenms/includes/discovery/sensors/temperatures/aos-device.inc.php
  471. Including: /opt/librenms/includes/discovery/sensors/temperatures/apc.inc.php
  472. Including: /opt/librenms/includes/discovery/sensors/temperatures/areca.inc.php
  473. Including: /opt/librenms/includes/discovery/sensors/temperatures/avaya-ers.inc.php
  474. Including: /opt/librenms/includes/discovery/sensors/temperatures/avtech.inc.php
  475. Including: /opt/librenms/includes/discovery/sensors/temperatures/binos.inc.php
  476. Including: /opt/librenms/includes/discovery/sensors/temperatures/binox.inc.php
  477. Including: /opt/librenms/includes/discovery/sensors/temperatures/calix.inc.php
  478. Including: /opt/librenms/includes/discovery/sensors/temperatures/cambium.inc.php
  479. Including: /opt/librenms/includes/discovery/sensors/temperatures/canopy.inc.php
  480. Including: /opt/librenms/includes/discovery/sensors/temperatures/ceraos.inc.php
  481. Including: /opt/librenms/includes/discovery/sensors/temperatures/cimc.inc.php
  482. Including: /opt/librenms/includes/discovery/sensors/temperatures/cisco-envmon.inc.php
  483. Including: /opt/librenms/includes/discovery/sensors/temperatures/ciscowlc.inc.php
  484. Including: /opt/librenms/includes/discovery/sensors/temperatures/cometsystem-p85xx.inc.php
  485. Including: /opt/librenms/includes/discovery/sensors/temperatures/comware.inc.php
  486. Including: /opt/librenms/includes/discovery/sensors/temperatures/dell.inc.php
  487. Including: /opt/librenms/includes/discovery/sensors/temperatures/dnos-ftos-s-series.inc.php
  488. Including: /opt/librenms/includes/discovery/sensors/temperatures/dnos.inc.php
  489. Including: /opt/librenms/includes/discovery/sensors/temperatures/drac.inc.php
  490. Including: /opt/librenms/includes/discovery/sensors/temperatures/dsm.inc.php
  491. Including: /opt/librenms/includes/discovery/sensors/temperatures/edgeswitch.inc.php
  492. Including: /opt/librenms/includes/discovery/sensors/temperatures/equallogic.inc.php
  493. Including: /opt/librenms/includes/discovery/sensors/temperatures/extreme.inc.php
  494. Including: /opt/librenms/includes/discovery/sensors/temperatures/f5.inc.php
  495. Including: /opt/librenms/includes/discovery/sensors/temperatures/fiberhome.inc.php
  496. Including: /opt/librenms/includes/discovery/sensors/temperatures/ftos-c-series.inc.php
  497. Including: /opt/librenms/includes/discovery/sensors/temperatures/ftos-e-series.inc.php
  498. Including: /opt/librenms/includes/discovery/sensors/temperatures/hpblmos.inc.php
  499. Including: /opt/librenms/includes/discovery/sensors/temperatures/hpilo.inc.php
  500. Including: /opt/librenms/includes/discovery/sensors/temperatures/hwg-ste.inc.php
  501. Including: /opt/librenms/includes/discovery/sensors/temperatures/hwg-ste2.inc.php
  502. Including: /opt/librenms/includes/discovery/sensors/temperatures/hytera.inc.php
  503. Including: /opt/librenms/includes/discovery/sensors/temperatures/ibm-amm.inc.php
  504. Including: /opt/librenms/includes/discovery/sensors/temperatures/ibmnos.inc.php
  505. Including: /opt/librenms/includes/discovery/sensors/temperatures/ipoman.inc.php
  506. Including: /opt/librenms/includes/discovery/sensors/temperatures/ironware.inc.php
  507. Including: /opt/librenms/includes/discovery/sensors/temperatures/junos.inc.php
  508. Including: /opt/librenms/includes/discovery/sensors/temperatures/junose.inc.php
  509. Including: /opt/librenms/includes/discovery/sensors/temperatures/lantronix-slc.inc.php
  510. Including: /opt/librenms/includes/discovery/sensors/temperatures/linux.inc.php
  511. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
  512. "console=ttyS0,115200 root=/dev/ram init=zyinit \"\"
  513. "
  514.  
  515. Including: /opt/librenms/includes/discovery/sensors/temperatures/lm-sensors.inc.php
  516. Including: /opt/librenms/includes/discovery/sensors/temperatures/mgeups.inc.php
  517. Including: /opt/librenms/includes/discovery/sensors/temperatures/mikrotik.inc.php
  518. Including: /opt/librenms/includes/discovery/sensors/temperatures/mimosa.inc.php
  519. Including: /opt/librenms/includes/discovery/sensors/temperatures/netagent2.inc.php
  520. Including: /opt/librenms/includes/discovery/sensors/temperatures/netapp.inc.php
  521. Including: /opt/librenms/includes/discovery/sensors/temperatures/netbotz.inc.php
  522. Including: /opt/librenms/includes/discovery/sensors/temperatures/netonix.inc.php
  523. Including: /opt/librenms/includes/discovery/sensors/temperatures/nos.inc.php
  524. Including: /opt/librenms/includes/discovery/sensors/temperatures/observernms-custom.inc.php
  525. Including: /opt/librenms/includes/discovery/sensors/temperatures/papouch-tme.inc.php
  526. Including: /opt/librenms/includes/discovery/sensors/temperatures/pbn.inc.php
  527. Including: /opt/librenms/includes/discovery/sensors/temperatures/pcoweb.inc.php
  528. Including: /opt/librenms/includes/discovery/sensors/temperatures/powerconnect.inc.php
  529. Including: /opt/librenms/includes/discovery/sensors/temperatures/powerware.inc.php
  530. Including: /opt/librenms/includes/discovery/sensors/temperatures/qnap.inc.php
  531. Including: /opt/librenms/includes/discovery/sensors/temperatures/rfc1628.inc.php
  532. Including: /opt/librenms/includes/discovery/sensors/temperatures/riverbed.inc.php
  533. Including: /opt/librenms/includes/discovery/sensors/temperatures/saf.inc.php
  534. Including: /opt/librenms/includes/discovery/sensors/temperatures/sentry3.inc.php
  535. Including: /opt/librenms/includes/discovery/sensors/temperatures/sentry4.inc.php
  536. Including: /opt/librenms/includes/discovery/sensors/temperatures/serveriron.inc.php
  537. Including: /opt/librenms/includes/discovery/sensors/temperatures/siklu.inc.php
  538. Including: /opt/librenms/includes/discovery/sensors/temperatures/sub10.inc.php
  539. Including: /opt/librenms/includes/discovery/sensors/temperatures/supermicro.inc.php
  540. Including: /opt/librenms/includes/discovery/sensors/temperatures/zyxel-ies.inc.php
  541. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  542.  
  543. Humidity : Including: /opt/librenms/includes/discovery/sensors/humidity/akcp.inc.php
  544. Including: /opt/librenms/includes/discovery/sensors/humidity/apc.inc.php
  545. Including: /opt/librenms/includes/discovery/sensors/humidity/hwg-ste2.inc.php
  546. Including: /opt/librenms/includes/discovery/sensors/humidity/ipoman.inc.php
  547. Including: /opt/librenms/includes/discovery/sensors/humidity/mgeups.inc.php
  548. Including: /opt/librenms/includes/discovery/sensors/humidity/netbotz.inc.php
  549. Including: /opt/librenms/includes/discovery/sensors/humidity/pcoweb.inc.php
  550. Including: /opt/librenms/includes/discovery/sensors/humidity/sentry3.inc.php
  551. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  552.  
  553. Voltages: Including: /opt/librenms/includes/discovery/sensors/voltages/apc.inc.php
  554. Including: /opt/librenms/includes/discovery/sensors/voltages/areca.inc.php
  555. Including: /opt/librenms/includes/discovery/sensors/voltages/ceraos.inc.php
  556. Including: /opt/librenms/includes/discovery/sensors/voltages/comware.inc.php
  557. Including: /opt/librenms/includes/discovery/sensors/voltages/drac.inc.php
  558. Including: /opt/librenms/includes/discovery/sensors/voltages/dsm.inc.php
  559. Including: /opt/librenms/includes/discovery/sensors/voltages/eatonups.inc.php
  560. Including: /opt/librenms/includes/discovery/sensors/voltages/gamatronicups.inc.php
  561. Including: /opt/librenms/includes/discovery/sensors/voltages/hytera.inc.php
  562. Including: /opt/librenms/includes/discovery/sensors/voltages/ipoman.inc.php
  563. Including: /opt/librenms/includes/discovery/sensors/voltages/linux.inc.php
  564. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
  565. "console=ttyS0,115200 root=/dev/ram init=zyinit \"\"
  566. "
  567.  
  568. Including: /opt/librenms/includes/discovery/sensors/voltages/mgeups.inc.php
  569. Including: /opt/librenms/includes/discovery/sensors/voltages/mikrotik.inc.php
  570. Including: /opt/librenms/includes/discovery/sensors/voltages/netagent2.inc.php
  571. Including: /opt/librenms/includes/discovery/sensors/voltages/netonix.inc.php
  572. Including: /opt/librenms/includes/discovery/sensors/voltages/netvision.inc.php
  573. Including: /opt/librenms/includes/discovery/sensors/voltages/pbn.inc.php
  574. Including: /opt/librenms/includes/discovery/sensors/voltages/powerware.inc.php
  575. Including: /opt/librenms/includes/discovery/sensors/voltages/rfc1628.inc.php
  576. Including: /opt/librenms/includes/discovery/sensors/voltages/saf.inc.php
  577. Including: /opt/librenms/includes/discovery/sensors/voltages/sentry3.inc.php
  578. Including: /opt/librenms/includes/discovery/sensors/voltages/siklu.inc.php
  579. Including: /opt/librenms/includes/discovery/sensors/voltages/sinetica.inc.php
  580. Including: /opt/librenms/includes/discovery/sensors/voltages/supermicro.inc.php
  581. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  582.  
  583. Frequencies: Including: /opt/librenms/includes/discovery/sensors/frequencies/apc.inc.php
  584. Including: /opt/librenms/includes/discovery/sensors/frequencies/eatonups.inc.php
  585. Including: /opt/librenms/includes/discovery/sensors/frequencies/ipoman.inc.php
  586. Including: /opt/librenms/includes/discovery/sensors/frequencies/linux.inc.php
  587. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
  588. "console=ttyS0,115200 root=/dev/ram init=zyinit \"\"
  589. "
  590.  
  591. Including: /opt/librenms/includes/discovery/sensors/frequencies/mgeups.inc.php
  592. Including: /opt/librenms/includes/discovery/sensors/frequencies/netagent2.inc.php
  593. Including: /opt/librenms/includes/discovery/sensors/frequencies/netvision.inc.php
  594. Including: /opt/librenms/includes/discovery/sensors/frequencies/powerware.inc.php
  595. Including: /opt/librenms/includes/discovery/sensors/frequencies/raritan.inc.php
  596. Including: /opt/librenms/includes/discovery/sensors/frequencies/rfc1628.inc.php
  597. Including: /opt/librenms/includes/discovery/sensors/frequencies/sinetica.inc.php
  598. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  599.  
  600. Runtime: Including: /opt/librenms/includes/discovery/sensors/runtime/apc.inc.php
  601. Including: /opt/librenms/includes/discovery/sensors/runtime/sinetica.inc.php
  602. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  603.  
  604. Current: Including: /opt/librenms/includes/discovery/sensors/current/apc.inc.php
  605. Including: /opt/librenms/includes/discovery/sensors/current/comware.inc.php
  606. Including: /opt/librenms/includes/discovery/sensors/current/eatonpdu.inc.php
  607. Including: /opt/librenms/includes/discovery/sensors/current/eatonups.inc.php
  608. Including: /opt/librenms/includes/discovery/sensors/current/gamatronicups.inc.php
  609. Including: /opt/librenms/includes/discovery/sensors/current/ipoman.inc.php
  610. Including: /opt/librenms/includes/discovery/sensors/current/junos.inc.php
  611. Including: /opt/librenms/includes/discovery/sensors/current/mgeups.inc.php
  612. Including: /opt/librenms/includes/discovery/sensors/current/netagent2.inc.php
  613. Including: /opt/librenms/includes/discovery/sensors/current/netonix.inc.php
  614. Including: /opt/librenms/includes/discovery/sensors/current/netvision.inc.php
  615. Including: /opt/librenms/includes/discovery/sensors/current/pbn.inc.php
  616. Including: /opt/librenms/includes/discovery/sensors/current/powerware.inc.php
  617. Including: /opt/librenms/includes/discovery/sensors/current/raritan.inc.php
  618. Including: /opt/librenms/includes/discovery/sensors/current/rfc1628.inc.php
  619. Including: /opt/librenms/includes/discovery/sensors/current/sentry3.inc.php
  620. Including: /opt/librenms/includes/discovery/sensors/current/sinetica.inc.php
  621. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  622.  
  623. Power: Including: /opt/librenms/includes/discovery/sensors/power/cimc.inc.php
  624. Including: /opt/librenms/includes/discovery/sensors/power/ciscosb.inc.php
  625. Including: /opt/librenms/includes/discovery/sensors/power/dsm.inc.php
  626. Including: /opt/librenms/includes/discovery/sensors/power/extreme.inc.php
  627. Including: /opt/librenms/includes/discovery/sensors/power/hpblmos.inc.php
  628. Including: /opt/librenms/includes/discovery/sensors/power/ipoman.inc.php
  629. Including: /opt/librenms/includes/discovery/sensors/power/netonix.inc.php
  630. Including: /opt/librenms/includes/discovery/sensors/power/raritan.inc.php
  631. Including: /opt/librenms/includes/discovery/sensors/power/rfc1628.inc.php
  632. Including: /opt/librenms/includes/discovery/sensors/power/sinetica.inc.php
  633. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  634.  
  635. Fanspeeds : Including: /opt/librenms/includes/discovery/sensors/fanspeeds/areca.inc.php
  636. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/dell.inc.php
  637. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/drac.inc.php
  638. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/equallogic.inc.php
  639. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/extreme.inc.php
  640. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/f5.inc.php
  641. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/ibm-amm.inc.php
  642. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/lmsensors.inc.php
  643. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/mikrotik.inc.php
  644. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/netonix.inc.php
  645. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/nos.inc.php
  646. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/qnap.inc.php
  647. Including: /opt/librenms/includes/discovery/sensors/fanspeeds/supermicro.inc.php
  648. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  649.  
  650. Battery Charge: Including: /opt/librenms/includes/discovery/sensors/charge/apc.inc.php
  651. Including: /opt/librenms/includes/discovery/sensors/charge/dsm.inc.php
  652. Including: /opt/librenms/includes/discovery/sensors/charge/netagent2.inc.php
  653. Including: /opt/librenms/includes/discovery/sensors/charge/rfc1628.inc.php
  654. Including: /opt/librenms/includes/discovery/sensors/charge/sinetica.inc.php
  655. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  656.  
  657. Load: Including: /opt/librenms/includes/discovery/sensors/load/apc.inc.php
  658. Including: /opt/librenms/includes/discovery/sensors/load/dsm.inc.php
  659. Including: /opt/librenms/includes/discovery/sensors/load/netagent2.inc.php
  660. Including: /opt/librenms/includes/discovery/sensors/load/rfc1628.inc.php
  661. Including: /opt/librenms/includes/discovery/sensors/load/sinetica.inc.php
  662. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  663.  
  664. States: Including: /opt/librenms/includes/discovery/sensors/states/asa.inc.php
  665. Including: /opt/librenms/includes/discovery/sensors/states/avtech.inc.php
  666. Including: /opt/librenms/includes/discovery/sensors/states/cisco.inc.php
  667. Including: /opt/librenms/includes/discovery/sensors/states/comware.inc.php
  668. Including: /opt/librenms/includes/discovery/sensors/states/ddnos.inc.php
  669. Including: /opt/librenms/includes/discovery/sensors/states/dell.inc.php
  670. Including: /opt/librenms/includes/discovery/sensors/states/drac.inc.php
  671. Including: /opt/librenms/includes/discovery/sensors/states/dsm.inc.php
  672. Including: /opt/librenms/includes/discovery/sensors/states/edgeswitch.inc.php
  673. Including: /opt/librenms/includes/discovery/sensors/states/equallogic.inc.php
  674. Including: /opt/librenms/includes/discovery/sensors/states/f5.inc.php
  675. Including: /opt/librenms/includes/discovery/sensors/states/hpblmos.inc.php
  676. Including: /opt/librenms/includes/discovery/sensors/states/hwg-ste.inc.php
  677. Including: /opt/librenms/includes/discovery/sensors/states/ibm-amm.inc.php
  678. Including: /opt/librenms/includes/discovery/sensors/states/ironware.inc.php
  679. Including: /opt/librenms/includes/discovery/sensors/states/juniper.inc.php
  680. Including: /opt/librenms/includes/discovery/sensors/states/linux.inc.php
  681. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
  682. "console=ttyS0,115200 root=/dev/ram init=zyinit \"\"
  683. "
  684.  
  685. Including: /opt/librenms/includes/discovery/sensors/states/mimosa.inc.php
  686. Including: /opt/librenms/includes/discovery/sensors/states/netagent2.inc.php
  687. Including: /opt/librenms/includes/discovery/sensors/states/netonix.inc.php
  688. Including: /opt/librenms/includes/discovery/sensors/states/nxos.inc.php
  689. Including: /opt/librenms/includes/discovery/sensors/states/pcoweb.inc.php
  690. Including: /opt/librenms/includes/discovery/sensors/states/qnap.inc.php
  691. Including: /opt/librenms/includes/discovery/sensors/states/rfc1628.inc.php
  692. Including: /opt/librenms/includes/discovery/sensors/states/riverbed.inc.php
  693. Including: /opt/librenms/includes/discovery/sensors/states/serveriron.inc.php
  694. Including: /opt/librenms/includes/discovery/sensors/states/waas.inc.php
  695. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  696.  
  697. dBm: Including: /opt/librenms/includes/discovery/sensors/dbm/comware.inc.php
  698. Including: /opt/librenms/includes/discovery/sensors/dbm/datacom.inc.php
  699. Including: /opt/librenms/includes/discovery/sensors/dbm/junos.inc.php
  700. Including: /opt/librenms/includes/discovery/sensors/dbm/pbn.inc.php
  701. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  702.  
  703. Signal: Including: /opt/librenms/includes/discovery/sensors/signal/cambium.inc.php
  704. Including: /opt/librenms/includes/discovery/sensors/signal/canopy.inc.php
  705. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '2' AND S.poller_type = 'snmp']
  706.  
  707.  
  708. >> Runtime for discovery module 'sensors': 15.3600 seconds
  709. #### Unload disco module sensors ####
  710.  
  711. Modules status: Global+ OS Device
  712. #### Load disco module storage ####
  713. Including: /opt/librenms/includes/discovery/storage/eql-storage.inc.php
  714. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs/equallogic:/opt/librenms/mibs udp:HOSTNAME:161 EqliscsiVolumeEntry]
  715. eqliscsiVolumeEntry = No Such Object available on this agent at this OID
  716.  
  717. Including: /opt/librenms/includes/discovery/storage/hrstorage.inc.php
  718. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry]
  719. hrStorageEntry = No Such Object available on this agent at this OID
  720.  
  721. Including: /opt/librenms/includes/discovery/storage/netapp-storage.inc.php
  722. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dfEntry]
  723. dfEntry = No Such Object available on this agent at this OID
  724.  
  725. Including: /opt/librenms/includes/discovery/storage/ucd-dsktable.inc.php
  726. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dskTable]
  727. dskTable = No Such Object available on this agent at this OID
  728.  
  729. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '2' AND `storage_type` != 'dsk']
  730. SQL[SELECT * FROM `storage` WHERE `device_id` = '2']
  731.  
  732.  
  733. >> Runtime for discovery module 'storage': 3.9110 seconds
  734. #### Unload disco module storage ####
  735.  
  736. Modules status: Global+ OS Device
  737. #### Load disco module hr-device ####
  738. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry]
  739. hrDeviceEntry = No Such Object available on this agent at this OID
  740.  
  741. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry]
  742. hrProcessorEntry = No Such Object available on this agent at this OID
  743.  
  744. Array
  745. (
  746. )
  747. SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '2']
  748.  
  749.  
  750. >> Runtime for discovery module 'hr-device': 0.0690 seconds
  751. #### Unload disco module hr-device ####
  752.  
  753. Modules status: Global+ OS Device
  754. #### Load disco module discovery-protocols ####
  755. CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 cdpCache]
  756. cdpCache = No Such Object available on this agent at this OID
  757.  
  758. Array
  759. (
  760. )
  761. LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 lldpRemoteSystemsData]
  762. lldpRemoteSystemsData = No Such Object available on this agent at this OID
  763.  
  764. lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData || || ||
  765. Array
  766. (
  767. )
  768. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex]
  769. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  770.  
  771. Array
  772. (
  773. )
  774. OSPF Discovery: enabled
  775. SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='2']
  776. SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '2']
  777.  
  778.  
  779. >> Runtime for discovery module 'discovery-protocols': 3.8720 seconds
  780. #### Unload disco module discovery-protocols ####
  781.  
  782. Modules status: Global+ OS Device
  783. #### Load disco module arp-table ####
  784. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
  785. ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  786.  
  787. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress]
  788. ipNetToMediaPhysAddress.*.20 = 0:c:29:a8:98:78
  789. ipNetToMediaPhysAddress.*.150 = 0:c:29:98:39:47
  790. ipNetToMediaPhysAddress.*.193 = 0:0:c:9f:f0:1
  791. ipNetToMediaPhysAddress.*.197 = 0:0:0:0:0:0
  792. ipNetToMediaPhysAddress.*.100 = 0:8:9b:c2:15:c2
  793. ipNetToMediaPhysAddress.*.1 = 0:c:29:8c:e7:3b
  794.  
  795. SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='2' AND M.context_name='']
  796. SQL[SELECT * FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '6']
  797. SQL[SELECT * FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '7']
  798. SQL[SELECT * FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '10']
  799. SQL[SELECT * FROM `ports` WHERE `device_id` = '2' AND `ifIndex` = '11']
  800.  
  801.  
  802. >> Runtime for discovery module 'arp-table': 0.3980 seconds
  803. #### Unload disco module arp-table ####
  804.  
  805. Modules status: Global- OS Device Module [ discovery-arp ] disabled globally.
  806.  
  807. Modules status: Global+ OS Device
  808. #### Load disco module junose-atm-vp ####
  809.  
  810. >> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds
  811. #### Unload disco module junose-atm-vp ####
  812.  
  813. Modules status: Global+ OS Device
  814. #### Load disco module bgp-peers ####
  815. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.15.2]
  816. No Such Object available on this agent at this OID
  817.  
  818. No BGP on hostSQL[SELECT * FROM bgpPeers WHERE device_id = '2' AND (context_name = '' OR context_name IS NULL)]
  819.  
  820. FIN BGP
  821.  
  822.  
  823.  
  824. >> Runtime for discovery module 'bgp-peers': 0.0320 seconds
  825. #### Unload disco module bgp-peers ####
  826.  
  827. Modules status: Global+ OS Device
  828. #### Load disco module vlans ####
  829. SQL[SELECT * FROM `vlans` WHERE `device_id` = '2']
  830. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex]
  831. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  832.  
  833. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0]
  834. No Such Object available on this agent at this OID
  835.  
  836.  
  837. SQL[DELETE FROM `ports_vlans` WHERE `device_id`='2' AND `port_vlan_id` NOT IN ()]
  838. Deleted vlan mappings
  839.  
  840. >> Runtime for discovery module 'vlans': 0.0680 seconds
  841. #### Unload disco module vlans ####
  842.  
  843. Modules status: Global+ OS Device
  844. #### Load disco module cisco-mac-accounting ####
  845.  
  846. >> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds
  847. #### Unload disco module cisco-mac-accounting ####
  848.  
  849. Modules status: Global+ OS Device
  850. #### Load disco module cisco-pw ####
  851.  
  852. >> Runtime for discovery module 'cisco-pw': 8.4870 seconds
  853. #### Unload disco module cisco-pw ####
  854.  
  855. Modules status: Global+ OS Device
  856. #### Load disco module cisco-vrf ####
  857.  
  858. >> Runtime for discovery module 'cisco-vrf': 0.0000 seconds
  859. #### Unload disco module cisco-vrf ####
  860.  
  861. Modules status: Global+ OS Device
  862. #### Load disco module cisco-sla ####
  863.  
  864. >> Runtime for discovery module 'cisco-sla': 0.0000 seconds
  865. #### Unload disco module cisco-sla ####
  866.  
  867. Modules status: Global+ OS Device
  868. #### Load disco module vmware-vminfo ####
  869.  
  870. >> Runtime for discovery module 'vmware-vminfo': 8.2960 seconds
  871. #### Unload disco module vmware-vminfo ####
  872.  
  873. Modules status: Global+ OS Device
  874. #### Load disco module libvirt-vminfo ####
  875.  
  876. >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds
  877. #### Unload disco module libvirt-vminfo ####
  878.  
  879. Modules status: Global+ OS Device
  880. #### Load disco module toner ####
  881.  
  882. Checking valid toner ...
  883. Array
  884. (
  885. )
  886. SQL[SELECT * FROM toner WHERE device_id = '2']
  887.  
  888.  
  889. >> Runtime for discovery module 'toner': 0.0000 seconds
  890. #### Unload disco module toner ####
  891.  
  892. Modules status: Global+ OS Device
  893. #### Load disco module ucd-diskio ####
  894. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry]
  895. diskIOEntry = No Such Object available on this agent at this OID
  896.  
  897. Array
  898. (
  899. )
  900. SQL[SELECT * FROM `ucd_diskio` where `device_id` = '2']
  901.  
  902.  
  903. >> Runtime for discovery module 'ucd-diskio': 0.0220 seconds
  904. #### Unload disco module ucd-diskio ####
  905.  
  906. Modules status: Global+ OS Device
  907. #### Load disco module services ####
  908.  
  909. >> Runtime for discovery module 'services': 0.0000 seconds
  910. #### Unload disco module services ####
  911.  
  912. Modules status: Global+ OS Device
  913. #### Load disco module charge ####
  914.  
  915. >> Runtime for discovery module 'charge': 4.7200 seconds
  916. #### Unload disco module charge ####
  917.  
  918. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally.
  919.  
  920. Modules status: Global+ OS Device
  921. #### Load disco module stp ####
  922. SQL[SELECT * FROM `stp` WHERE `device_id` = '2']
  923. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs/zyxel:/opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
  924. No Such Object available on this agent at this OID
  925.  
  926.  
  927.  
  928. >> Runtime for discovery module 'stp': 0.0210 seconds
  929. #### Unload disco module stp ####
  930.  
  931. Modules status: Global+ OS Device
  932. #### Load disco module cisco-otv ####
  933.  
  934. >> Runtime for discovery module 'cisco-otv': 0.0000 seconds
  935. #### Unload disco module cisco-otv ####
  936.  
  937. Modules status: Global+ OS Device
  938. #### Load disco module ntp ####
  939.  
  940. >> Runtime for discovery module 'ntp': 4.5060 seconds
  941. #### Unload disco module ntp ####
  942.  
  943. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '2' AND `attrib_type` = 'poll_mib' ]
  944. SQL[UPDATE `devices` set `last_discovered` =NOW(),`type` ='firewall',`last_discovered_timetaken` ='42.54' WHERE `device_id` = '2']
  945. Discovered in 42.54 seconds
  946.  
  947. SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`) VALUES ('discover','zywall.dc.novaware.nl','1481932086.6145','42.55','1')]
  948. /opt/librenms/discovery.php zywall.dc.novaware.nl 2016-12-17 00:48:49 - 1 devices discovered in 42.55 secs
  949. SNMP: Get[23/1.73s] Walk [28/36.81s]
  950. MySQL: Cell[43/0.01s] Row[7/0.00s] Rows[38/0.02s] Column[1/0.00s] Update[17/0.01s] Insert[1/0.00s] Delete[1/0.00s]