  1. Adapter #0
  2.  
  3. ==============================================================================
  4. Versions
  5. ================
  6. Product Name : LSI MegaRAID SAS 9260-8i
  7. Serial No : SV04607311
  8. FW Package Build: 12.12.0-0048
  9.  
  10. Mfg. Data
  11. ================
  12. Mfg. Date : 11/08/10
  13. Rework Date : 00/00/00
  14. Revision No :
  15. Battery FRU : N/A
  16.  
  17. Image Versions in Flash:
  18. ================
  19. FW Version : 2.120.63-1242
  20. BIOS Version : 3.22.00_4.11.05.00_0x05020000
  21. Preboot CLI Version: 04.04-017:#%00008
  22. WebBIOS Version : 6.0-34-e_29-Rel
  23. NVDATA Version : 2.09.03-0013
  24. Boot Block Version : 2.02.00.00-0000
  25. BOOT Version : 09.250.01.219
  26.  
  27. Pending Images in Flash
  28. ================
  29. None
  30.  
  31. PCI Info
  32. ================
  33. Controller Id : 0000
  34. Vendor Id : 1000
  35. Device Id : 0079
  36. SubVendorId : 1014
  37. SubDeviceId : 03c7
  38.  
  39. Host Interface : PCIE
  40.  
  41. ChipRevision : B2
  42.  
  43. Number of Frontend Port: 0
  44. Device Interface : PCIE
  45.  
  46. Number of Backend Port: 8
  47. Port : Address
  48. 0 4433221100000000
  49. 1 4433221101000000
  50. 2 4433221105000000
  51. 3 4433221106000000
  52. 4 4433221107000000
  53. 5 4433221103000000
  54. 6 4433221102000000
  55. 7 0000000000000000
  56.  
  57. HW Configuration
  58. ================
  59. SAS Address : 500605b002deaf30
  60. BBU : Present
  61. Alarm : Present
  62. NVRAM : Present
  63. Serial Debugger : Present
  64. Memory : Present
  65. Flash : Present
  66. Memory Size : 256MB
  67. TPM : Absent
  68. On board Expander: Absent
  69. Upgrade Key : Absent
  70. Temperature sensor for ROC : Absent
  71. Temperature sensor for controller : Absent
  72.  
  73.  
  74. Settings
  75. ================
  76. Current Time : 8:51:8 4/27, 2015
  77. Predictive Fail Poll Interval : 300sec
  78. Interrupt Throttle Active Count : 16
  79. Interrupt Throttle Completion : 50us
  80. Rebuild Rate : 30%
  81. PR Rate : 30%
  82. BGI Rate : 30%
  83. Check Consistency Rate : 30%
  84. Reconstruction Rate : 100%
  85. Cache Flush Interval : 4s
  86. Max Drives to Spinup at One Time : 4
  87. Delay Among Spinup Groups : 2s
  88. Physical Drive Coercion Mode : Disabled
  89. Cluster Mode : Disabled
  90. Alarm : Enabled
  91. Auto Rebuild : Enabled
  92. Battery Warning : Enabled
  93. Ecc Bucket Size : 15
  94. Ecc Bucket Leak Rate : 1440 Minutes
  95. Restore HotSpare on Insertion : Disabled
  96. Expose Enclosure Devices : Enabled
  97. Maintain PD Fail History : Enabled
  98. Host Request Reordering : Enabled
  99. Auto Detect BackPlane Enabled : SGPIO/i2c SEP
  100. Load Balance Mode : Auto
  101. Use FDE Only : No
  102. Security Key Assigned : No
  103. Security Key Failed : No
  104. Security Key Not Backedup : No
  105. Default LD PowerSave Policy : Controller Defined
  106. Maximum number of direct attached drives to spin up in 1 min : 120
  107. Auto Enhanced Import : No
  108. Any Offline VD Cache Preserved : No
  109. Allow Boot with Preserved Cache : No
  110. Disable Online Controller Reset : No
  111. PFK in NVRAM : No
  112. Use disk activity for locate : No
  113. POST delay : 90 seconds
  114.  
  115. Capabilities
  116. ================
  117. RAID Level Supported : RAID0, RAID1, RAID5, RAID00, RAID10, RAID50, PRL 11, PRL 11 with spanning, SRL 3 supported, PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
  118. Supported Drives : SAS, SATA
  119. Boot Volume Supported : NO
  120.  
  121. Allowed Mixing:
  122.  
  123. Mix in Enclosure Allowed
  124. Mix of SAS/SATA of HDD type in VD Allowed
  125.  
  126. Status
  127. ================
  128. ECC Bucket Count : 0
  129.  
  130. Limitations
  131. ================
  132. Max Arms Per VD : 32
  133. Max Spans Per VD : 8
  134. Max Arrays : 128
  135. Max Number of VDs : 64
  136. Max Parallel Commands : 1008
  137. Max SGE Count : 80
  138. Max Data Transfer Size : 8192 sectors
  139. Max Strips PerIO : 42
  140. Max LD per array : 16
  141. Min Strip Size : 8 KB
  142. Max Strip Size : 1.0 MB
  143. Max Configurable CacheCade Size: 0 GB
  144. Current Size of CacheCade : 0 GB
  145. Current Size of FW Cache : 145 MB
  146.  
  147. Device Present
  148. ================
  149. Virtual Drives : 1
  150. Degraded : 0
  151. Offline : 0
  152. Physical Devices : 8
  153. Disks : 7
  154. Critical Disks : 0
  155. Failed Disks : 0
  156.  
  157. Supported Adapter Operations
  158. ================
  159. Rebuild Rate : Yes
  160. CC Rate : Yes
  161. BGI Rate : Yes
  162. Reconstruct Rate : Yes
  163. Patrol Read Rate : Yes
  164. Alarm Control : Yes
  165. Cluster Support : No
  166. BBU : Yes
  167. Spanning : Yes
  168. Dedicated Hot Spare : Yes
  169. Revertible Hot Spares : Yes
  170. Foreign Config Import : Yes
  171. Self Diagnostic : Yes
  172. Allow Mixed Redundancy on Array : No
  173. Global Hot Spares : Yes
  174. Deny SCSI Passthrough : No
  175. Deny SMP Passthrough : No
  176. Deny STP Passthrough : No
  177. Support Security : No
  178. Snapshot Enabled : No
  179. Support the OCE without adding drives : Yes
  180. Support PFK : No
  181. Support PI : No
  182. Support Boot Time PFK Change : No
  183. Disable Online PFK Change : No
  184. Support Shield State : No
  185. Block SSD Write Disk Cache Change: No
  186. Point In Time Progress: No
  187.  
  188. Supported VD Operations
  189. ================
  190. Read Policy : Yes
  191. Write Policy : Yes
  192. IO Policy : Yes
  193. Access Policy : Yes
  194. Disk Cache Policy : Yes
  195. Reconstruction : Yes
  196. Deny Locate : No
  197. Deny CC : No
  198. Allow Ctrl Encryption: No
  199. Enable LDBBM : No
  200. Support Breakmirror : No
  201. Power Savings : Yes
  202.  
  203. Supported PD Operations
  204. ================
  205. Force Online : Yes
  206. Force Offline : Yes
  207. Force Rebuild : Yes
  208. Deny Force Failed : No
  209. Deny Force Good/Bad : No
  210. Deny Missing Replace : No
  211. Deny Clear : No
  212. Deny Locate : No
  213. Support Temperature : Yes
  214. NCQ : No
  215. Disable Copyback : No
  216. Enable JBOD : No
  217. Enable Copyback on SMART : No
  218. Enable Copyback to SSD on SMART Error : Yes
  219. Enable SSD Patrol Read : No
  220. PR Correct Unconfigured Areas : Yes
  221. Enable Spin Down of UnConfigured Drives : No
  222. Disable Spin Down of hot spares : Yes
  223. Spin Down time : 30
  224. T10 Power State : Yes
  225. Error Counters
  226. ================
  227. Memory Correctable Errors : 0
  228. Memory Uncorrectable Errors : 0
  229.  
  230. High Availability Properties
  231. ================
  232. Topology Type : None
  233. Cluster Information
  234. ================
  235. Cluster Permitted : No
  236. Cluster Active : No
  237.  
  238. Default Settings
  239. ================
  240. Phy Polarity : 0
  241. Phy PolaritySplit : 0
  242. Background Rate : 30
  243. Strip Size : 64kB
  244. Flush Time : 4 seconds
  245. Write Policy : WB
  246. Read Policy : Adaptive
  247. Cache When BBU Bad : Disabled
  248. Cached IO : No
  249. SMART Mode : Mode 6
  250. Alarm Disable : Yes
  251. Coercion Mode : None
  252. ZCR Config : Unknown
  253. Dirty LED Shows Drive Activity : No
  254. BIOS Continue on Error : No
  255. Spin Down Mode : None
  256. Allowed Device Type : SAS/SATA Mix
  257. Allow Mix in Enclosure : Yes
  258. Allow HDD SAS/SATA Mix in VD : Yes
  259. Allow SSD SAS/SATA Mix in VD : No
  260. Allow HDD/SSD Mix in VD : No
  261. Allow SATA in Cluster : No
  262. Max Chained Enclosures : 16
  263. Disable Ctrl-R : Yes
  264. Enable Web BIOS : Yes
  265. Direct PD Mapping : No
  266. BIOS Enumerate VDs : Yes
  267. Restore Hot Spare on Insertion : No
  268. Expose Enclosure Devices : Yes
  269. Maintain PD Fail History : Yes
  270. Disable Puncturing : No
  271. Zero Based Enclosure Enumeration : No
  272. PreBoot CLI Enabled : Yes
  273. LED Show Drive Activity : Yes
  274. Cluster Disable : Yes
  275. SAS Disable : No
  276. Auto Detect BackPlane Enable : SGPIO/i2c SEP
  277. Use FDE Only : No
  278. Enable Led Header : Yes
  279. Delay during POST : 0
  280. EnableCrashDump : No
  281. Disable Online Controller Reset : No
  282. EnableLDBBM : No
  283. Un-Certified Hard Disk Drives : Allow
  284. Treat Single span R1E as R10 : No
  285. Max LD per array : 16
  286. Power Saving option : Don't Auto spin down Configured Drives
  287. Max power savings option is not allowed for LDs. Only T10 power conditions are to be used.
  288. Default spin down time in minutes: 30
  289. Enable JBOD : No
  290. TTY Log In Flash : No
  291. Auto Enhanced Import : No
  292. BreakMirror RAID Support : No
  293. Disable Join Mirror : No
  294. Enable Shield State : No
  295. Time taken to detect CME : 60s
  296.  
  297. Exit Code: 0x00