Guest User

smartctl.sda

a guest
Feb 26th, 2014
76
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 5.06 KB | None | 0 0
  1. smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-4-686-pae] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: ST500LM012 HN-M500MBB
  6. Serial Number: S2R7J9DDB07426
  7. LU WWN Device Id: 5 0004cf 20bbd56c8
  8. Firmware Version: 2AR10002
  9. User Capacity: 500.107.862.016 bytes [500 GB]
  10. Sector Sizes: 512 bytes logical, 4096 bytes physical
  11. Device is: Not in smartctl database [for details use: -P showall]
  12. ATA Version is: 8
  13. ATA Standard is: ATA-8-ACS revision 6
  14. Local Time is: Wed Feb 26 15:02:29 2014 CET
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x80) Offline data collection activity
  23. was never started.
  24. Auto Offline Data Collection: Enabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 6840) seconds.
  30. Offline data collection
  31. capabilities: (0x5b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. No Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 114) minutes.
  48. SCT capabilities: (0x003f) SCT Status supported.
  49. SCT Error Recovery Control supported.
  50. SCT Feature Control supported.
  51. SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 923
  57. 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
  58. 3 Spin_Up_Time 0x0023 091 090 025 Pre-fail Always - 2865
  59. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 331
  60. 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
  61. 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
  62. 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
  63. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 849
  64. 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
  65. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 11
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 257
  67. 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 23
  68. 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
  69. 194 Temperature_Celsius 0x0002 064 049 000 Old_age Always - 36 (Min/Max 11/52)
  70. 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
  71. 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
  72. 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 6
  73. 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 6
  74. 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0
  75. 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 420
  76. 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 11
  77. 225 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 17478
  78.  
  79. SMART Error Log Version: 1
  80. No Errors Logged
  81.  
  82. SMART Self-test log structure revision number 1
  83. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  84.  
  85.  
  86. Note: selective self-test log revision number (0) not 1 implies that no selective self-test has ever been run
  87. SMART Selective self-test log data structure revision number 0
  88. Note: revision number not 1 implies that no selective self-test has ever been run
  89. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  90. 1 0 0 Completed [00% left] (0-65535)
  91. 2 0 0 Not_testing
  92. 3 0 0 Not_testing
  93. 4 0 0 Not_testing
  94. 5 0 0 Not_testing
  95. Selective self-test flags (0x0):
  96. After scanning selected spans, do NOT read-scan remainder of disk.
  97. If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement
Add Comment
Please, Sign In to add comment