  1. smartctl 6.2 2014-07-16 r3952 [x86_64-linux-3.19.1-201.fc21.x86_64] (local build)
  2. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Caviar SE Serial ATA
  6. Device Model: WDC WD2500JS-75NCB3
  7. Serial Number: WD-WCANKL262477
  8. Firmware Version: 10.02E04
  9. User Capacity: 250,000,000,000 bytes [250 GB]
  10. Sector Size: 512 bytes logical/physical
  11. Device is: In smartctl database [for details use: -P show]
  12. ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
  13. Local Time is: Sun Apr 26 13:26:49 2015 CEST
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19. See vendor-specific Attribute list for marginal Attributes.
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x84) Offline data collection activity
  23. was suspended by an interrupting command from host.
  24. Auto Offline Data Collection: Enabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 7680) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 90) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 6) minutes.
  50. SCT capabilities: (0x103f) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
  59. 3 Spin_Up_Time 0x0003 194 179 021 Pre-fail Always - 5258
  60. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 46
  61. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
  63. 9 Power_On_Hours 0x0032 089 088 000 Old_age Always - 8148
  64. 10 Spin_Retry_Count 0x0013 100 253 051 Pre-fail Always - 0
  65. 11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always - 0
  66. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 46
  67. 190 Airflow_Temperature_Cel 0x0022 074 040 045 Old_age Always In_the_past 26
  68. 194 Temperature_Celsius 0x0022 124 090 000 Old_age Always - 26
  69. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  70. 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
  71. 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0
  72. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  73. 200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  80. # 1 Extended offline Completed without error 00% 1 -
  81. # 2 Short offline Completed without error 00% 0 -
  82.  
  83. SMART Selective self-test log data structure revision number 1
  84. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  85. 1 0 0 Not_testing
  86. 2 0 0 Not_testing
  87. 3 0 0 Not_testing
  88. 4 0 0 Not_testing
  89. 5 0 0 Not_testing
  90. Selective self-test flags (0x0):
  91. After scanning selected spans, do NOT read-scan remainder of disk.
  92. If Selective self-test is pending on power-up, resume after 0 minute delay.