- smartctl 6.2 2014-07-16 r3952 [x86_64-linux-3.19.1-201.fc21.x86_64] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar SE Serial ATA
- Device Model: WDC WD2500JS-75NCB3
- Serial Number: WD-WCANKL262477
- Firmware Version: 10.02E04
- User Capacity: 250,000,000,000 bytes [250 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
- Local Time is: Sun Apr 26 13:26:49 2015 CEST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 7680) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 90) minutes.
- Conveyance self-test routine
- recommended polling time: ( 6) minutes.
- SCT capabilities: (0x103f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0003 194 179 021 Pre-fail Always - 5258
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 46
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0
- 9 Power_On_Hours 0x0032 089 088 000 Old_age Always - 8148
- 10 Spin_Retry_Count 0x0013 100 253 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 100 253 051 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 46
- 190 Airflow_Temperature_Cel 0x0022 074 040 045 Old_age Always In_the_past 26
- 194 Temperature_Celsius 0x0022 124 090 000 Old_age Always - 26
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 253 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 1 -
- # 2 Short offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.