  1. smartctl 5.40 2010-10-16 r3189 [i686-pc-linux-gnu] (local build)
  2. Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Western Digital Caviar SE Serial ATA family
  6. Device Model: WDC WD2000JS-60NCB1
  7. Serial Number: WD-WMANL1429239
  8. Firmware Version: 10.02E02
  9. User Capacity: 200 049 647 616 bytes
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 7
  12. ATA Standard is: Exact ATA specification draft version not indicated
  13. Local Time is: Sun Apr 17 16:52:08 2011 YEKST
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: FAILED!
  19. Drive failure expected in less than 24 hours. SAVE ALL DATA.
  20. No failed Attributes found.
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x02) Offline data collection activity
  24. was completed without error.
  25. Auto Offline Data Collection: Disabled.
  26. Self-test execution status: ( 0) The previous self-test routine completed
  27. without error or no self-test has ever
  28. been run.
  29. Total time to complete Offline
  30. data collection: (6780) seconds.
  31. Offline data collection
  32. capabilities: (0x10) No SMART execute Offline immediate.
  33. No Auto Offline data collection support.
  34. Suspend Offline collection upon new
  35. command.
  36. No Offline surface scan supported.
  37. Self-test supported.
  38. No Conveyance Self-test supported.
  39. No Selective Self-test supported.
  40. SMART capabilities: (0x8040) Does not save SMART data before
  41. entering power-saving mode.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 80) minutes.
  48. SCT capabilities: (0x103f) SCT Status supported.
  49. SCT Error Recovery Control supported.
  50. SCT Feature Control supported.
  51. SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16513
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 128 Unknown_Attribute 0x1811 247 112 002 Pre-fail Offline - 176497386064440
  57. 32 Unknown_Attribute 0x4089 001 001 --- Pre-fail Offline - 140877542384700
  58. 32 Unknown_Attribute 0x4220 197 128 --- Old_age Offline - 35751307771928
  59. 9 Power_On_Hours 0x0860 001 001 --- Old_age Offline - 27307410174036
  60. 2 Throughput_Performance 0x8044 100 097 017 Old_age Offline - 41506563948544
  61. 1 Raw_Read_Error_Rate 0x4019 100 006 --- Pre-fail Offline - 73774653243392
  62. 66 Unknown_Attribute 0x0401 001 001 --- Pre-fail Offline - 5517820810086
  63. 105 Unknown_Attribute 0x0000 058 000 --- Old_age Offline - 42
  64. 128 Unknown_Attribute 0x5301 108 072 002 Pre-fail Offline - 147368917860394
  65. 72 Unknown_Attribute 0x0040 200 004 --- Old_age Offline - 79233556676608
  66. 72 Unknown_Attribute 0x4420 200 001 --- Old_age Offline - 141836999983104
  67. 16 Unknown_Attribute 0x0404 200 000 000 Old_age Offline - 2276706598847
  68. 64 Unknown_Attribute 0x0018 200 001 --- Old_age Offline - 6871947673600
  69.  
  70. SMART Error Log Version: 1
  71. ATA Error Count: 11 (device log contains only the most recent five errors)
  72. CR = Command Register [HEX]
  73. FR = Features Register [HEX]
  74. SC = Sector Count Register [HEX]
  75. SN = Sector Number Register [HEX]
  76. CL = Cylinder Low Register [HEX]
  77. CH = Cylinder High Register [HEX]
  78. DH = Device/Head Register [HEX]
  79. DC = Device Command Register [HEX]
  80. ER = Error register [HEX]
  81. ST = Status register [HEX]
  82. Powered_Up_Time is measured from power on, and printed as
  83. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  84. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  85.  
  86. Error 11 occurred at disk power-on lifetime: 34709 hours (1446 days + 5 hours)
  87. When the command that caused the error occurred, the device was active or idle.
  88.  
  89. After command completion occurred, registers were:
  90. ER ST SC SN CL CH DH
  91. -- -- -- -- -- -- --
  92. 40 51 01 80 7a 81 e0 Error: UNC at LBA = 0x00817a80 = 8485504
  93.  
  94. Commands leading to the command that caused the error were:
  95. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  96. -- -- -- -- -- -- -- -- ---------------- --------------------
  97. 42 00 01 80 7a 81 0c 00 00:33:30.838 READ VERIFY SECTOR(S) EXT
  98. 25 00 01 00 00 00 00 00 00:33:30.838 READ DMA EXT
  99. 42 00 01 7f 7a 81 0c 00 00:33:30.838 READ VERIFY SECTOR(S) EXT
  100. 35 00 08 f7 3b 00 00 00 00:33:30.838 WRITE DMA EXT
  101. 25 00 01 00 00 00 00 00 00:33:30.838 READ DMA EXT
  102.  
  103. Error 10 occurred at disk power-on lifetime: 34709 hours (1446 days + 5 hours)
  104. When the command that caused the error occurred, the device was active or idle.
  105.  
  106. After command completion occurred, registers were:
  107. ER ST SC SN CL CH DH
  108. -- -- -- -- -- -- --
  109. 40 51 02 7f 7a 81 e0 Error: UNC at LBA = 0x00817a7f = 8485503
  110.  
  111. Commands leading to the command that caused the error were:
  112. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  113. -- -- -- -- -- -- -- -- ---------------- --------------------
  114. 42 00 02 7f 7a 81 0c 00 00:33:28.950 READ VERIFY SECTOR(S) EXT
  115. 35 00 08 07 2a 00 00 00 00:33:28.950 WRITE DMA EXT
  116. 25 00 01 00 00 00 00 00 00:33:28.950 READ DMA EXT
  117. 35 00 08 3f 13 4e 00 00 00:33:28.950 WRITE DMA EXT
  118. 35 00 08 37 28 00 00 00 00:33:28.950 WRITE DMA EXT
  119.  
  120. Error 9 occurred at disk power-on lifetime: 34709 hours (1446 days + 5 hours)
  121. When the command that caused the error occurred, the device was active or idle.
  122.  
  123. After command completion occurred, registers were:
  124. ER ST SC SN CL CH DH
  125. -- -- -- -- -- -- --
  126. 40 51 04 7d 7a 81 e0 Error: UNC at LBA = 0x00817a7d = 8485501
  127.  
  128. Commands leading to the command that caused the error were:
  129. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  130. -- -- -- -- -- -- -- -- ---------------- --------------------
  131. 42 00 04 7d 7a 81 0c 00 00:33:27.018 READ VERIFY SECTOR(S) EXT
  132. 35 00 08 a7 08 00 00 00 00:33:27.018 WRITE DMA EXT
  133. 25 00 01 00 00 00 00 00 00:33:27.018 READ DMA EXT
  134. 35 00 08 6f 8f 00 00 00 00:33:27.018 WRITE DMA EXT
  135. 42 00 04 79 7a 81 0c 00 00:33:27.018 READ VERIFY SECTOR(S) EXT
  136.  
  137. Error 8 occurred at disk power-on lifetime: 34709 hours (1446 days + 5 hours)
  138. When the command that caused the error occurred, the device was active or idle.
  139.  
  140. After command completion occurred, registers were:
  141. ER ST SC SN CL CH DH
  142. -- -- -- -- -- -- --
  143. 40 51 08 79 7a 81 e0 Error: UNC at LBA = 0x00817a79 = 8485497
  144.  
  145. Commands leading to the command that caused the error were:
  146. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  147. -- -- -- -- -- -- -- -- ---------------- --------------------
  148. 42 00 08 79 7a 81 0c 00 00:33:25.063 READ VERIFY SECTOR(S) EXT
  149. 25 00 01 00 00 00 00 00 00:33:25.063 READ DMA EXT
  150. 35 00 08 0f 57 00 00 00 00:33:25.063 WRITE DMA EXT
  151. 42 00 10 89 7a 81 0c 00 00:33:25.047 READ VERIFY SECTOR(S) EXT
  152. 35 00 08 bf 56 00 00 00 00:33:25.047 WRITE DMA EXT
  153.  
  154. Error 7 occurred at disk power-on lifetime: 34709 hours (1446 days + 5 hours)
  155. When the command that caused the error occurred, the device was active or idle.
  156.  
  157. After command completion occurred, registers were:
  158. ER ST SC SN CL CH DH
  159. -- -- -- -- -- -- --
  160. 40 51 10 79 7a 81 e0 Error: UNC at LBA = 0x00817a79 = 8485497
  161.  
  162. Commands leading to the command that caused the error were:
  163. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  164. -- -- -- -- -- -- -- -- ---------------- --------------------
  165. 42 00 10 79 7a 81 0c 00 00:33:23.158 READ VERIFY SECTOR(S) EXT
  166. 35 00 08 9f 49 00 00 00 00:33:23.158 WRITE DMA EXT
  167. 25 00 01 00 00 00 00 00 00:33:23.158 READ DMA EXT
  168. 35 00 08 47 13 4e 00 00 00:33:23.158 WRITE DMA EXT
  169. 35 00 08 8f 49 00 00 00 00:33:23.157 WRITE DMA EXT
  170.  
  171. SMART Self-test log structure revision number 1
  172. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  173. # 1 Vendor (0x6e) Interrupted (host reset) 80% 54895 -
  174. # 2 Vendor (0xe7) Completed: servo/seek failure 130% 23862 2624044415
  175. # 3 Vendor (0xfd) Unknown status (0xa) 100% 40677 -
  176. # 4 Vendor (0xae) Self-test routine in progress 110% 19134 -
  177. # 5 Vendor (0xd5) Unknown status (0xe) 60% 9207 -
  178. # 6 Vendor (0x9a) Self-test routine in progress 60% 11165 -
  179. # 7 Abort offline test Self-test routine in progress 110% 44770 -
  180. # 8 Vendor (0xaa) Unknown status (0x9) 100% 65087 -
  181. # 9 Vendor (0x6b) Fatal or unknown error 60% 52182 4190088313
  182. #10 Vendor (0xff) Completed: servo/seek failure 150% 44254 2945195134
  183. #11 Vendor (0x40) Completed without error 00% 37904 -
  184. #12 Offline Completed without error 00% 264 -
  185. #13 Reserved (0x05) Completed without error 00% 97 -
  186. #14 Offline Completed: handling damage?? 00% 8992 142611328
  187. #15 Offline Completed without error 00% 392 -
  188. #16 Reserved (0x08) Completed: handling damage?? 00% 33232 34848
  189. #17 Short offline Completed without error 00% 1024 -
  190. #18 Reserved (0x11) Aborted by host 40% 10240 -
  191. #19 Extended offline Completed without error 60% 16528 -
  192. #20 Reserved (0x8a) Completed without error 40% 2112 -
  193. #21 Offline Completed without error 00% 344 -
  194.  
  195. Device does not support Selective Self Tests/Logging