- smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
- Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint F1 DT
- Device Model: SAMSUNG HD322HJ
- Serial Number: S17AJDWQ522311
- LU WWN Device Id: 5 0000f0 003253211
- Firmware Version: 1AC01112
- User Capacity: 320,072,933,376 bytes [320 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
- Local Time is: Mon Jan 30 11:28:17 2017 CET
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 3924) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 66) minutes.
- Conveyance self-test routine
- recommended polling time: ( 8) minutes.
- SCT capabilities: (0x003f) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 094 094 011 Pre-fail Always - 2890
- 4 Start_Stop_Count 0x0032 093 093 000 Old_age Always - 7046
- 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 9515
- 9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 18082
- 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 5
- 12 Power_Cycle_Count 0x0032 093 093 000 Old_age Always - 7016
- 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0
- 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
- 184 End-to-End_Error 0x0033 100 100 099 Pre-fail Always - 0
- 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 2
- 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 077 063 000 Old_age Always - 23 (Min/Max 17/23)
- 194 Temperature_Celsius 0x0022 073 060 000 Old_age Always - 27 (Min/Max 17/27)
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 913941
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 7
- 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 0
- Warning: ATA Specification requires self-test log structure revision number = 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 16420 -
- # 2 Extended offline Aborted by host 90% 16420 -
- SMART Selective self-test log data structure revision number 0
- Note: revision number not 1 implies that no selective self-test has ever been run
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
Advertisement