Guest User

Untitled

a guest
Jan 30th, 2017
119
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 5.47 KB | None | 0 0
  1. smartctl 6.4 2014-10-07 r4002 [x86_64-linux-3.16.0-4-amd64] (local build)
  2. Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: SAMSUNG SpinPoint F1 DT
  6. Device Model: SAMSUNG HD322HJ
  7. Serial Number: S17AJDWQ522311
  8. LU WWN Device Id: 5 0000f0 003253211
  9. Firmware Version: 1AC01112
  10. User Capacity: 320,072,933,376 bytes [320 GB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
  14. Local Time is: Mon Jan 30 11:28:17 2017 CET
  15. SMART support is: Available - device has SMART capability.
  16. SMART support is: Enabled
  17.  
  18. === START OF READ SMART DATA SECTION ===
  19. SMART overall-health self-assessment test result: PASSED
  20.  
  21. General SMART Values:
  22. Offline data collection status: (0x00) Offline data collection activity
  23. was never started.
  24. Auto Offline Data Collection: Disabled.
  25. Self-test execution status: ( 0) The previous self-test routine completed
  26. without error or no self-test has ever
  27. been run.
  28. Total time to complete Offline
  29. data collection: ( 3924) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 66) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 8) minutes.
  50. SCT capabilities: (0x003f) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
  59. 3 Spin_Up_Time 0x0007 094 094 011 Pre-fail Always - 2890
  60. 4 Start_Stop_Count 0x0032 093 093 000 Old_age Always - 7046
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
  62. 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
  63. 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 9515
  64. 9 Power_On_Hours 0x0032 096 096 000 Old_age Always - 18082
  65. 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
  66. 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 5
  67. 12 Power_Cycle_Count 0x0032 093 093 000 Old_age Always - 7016
  68. 13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0
  69. 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
  70. 184 End-to-End_Error 0x0033 100 100 099 Pre-fail Always - 0
  71. 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 2
  72. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  73. 190 Airflow_Temperature_Cel 0x0022 077 063 000 Old_age Always - 23 (Min/Max 17/23)
  74. 194 Temperature_Celsius 0x0022 073 060 000 Old_age Always - 27 (Min/Max 17/27)
  75. 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 913941
  76. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
  77. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  78. 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
  79. 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 7
  80. 200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
  81. 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0
  82.  
  83. SMART Error Log Version: 1
  84. No Errors Logged
  85.  
  86. SMART Self-test log structure revision number 0
  87. Warning: ATA Specification requires self-test log structure revision number = 1
  88. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  89. # 1 Short offline Completed without error 00% 16420 -
  90. # 2 Extended offline Aborted by host 90% 16420 -
  91.  
  92. SMART Selective self-test log data structure revision number 0
  93. Note: revision number not 1 implies that no selective self-test has ever been run
  94. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  95. 1 0 0 Not_testing
  96. 2 0 0 Not_testing
  97. 3 0 0 Not_testing
  98. 4 0 0 Not_testing
  99. 5 0 0 Not_testing
  100. Selective self-test flags (0x0):
  101. After scanning selected spans, do NOT read-scan remainder of disk.
  102. If Selective self-test is pending on power-up, resume after 0 minute delay.