- smartctl 5.43 2012-06-30 r3573 [i686-linux-3.10.4-pmagic] (local build)
- Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MK..55GSX
- Device Model: TOSHIBA MK2555GSX
- Serial Number: X9FKTDI5T
- LU WWN Device Id: 5 000039 211984010
- Firmware Version: FG000D
- User Capacity: 250,059,350,016 bytes [250 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: Exact ATA specification draft version not indicated
- Local Time is: Wed Feb 12 16:19:00 2014 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 89) The previous self-test completed having
- the electrical element of the test
- failed.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 92) minutes.
- SCT capabilities: (0x0039) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 128
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 885
- 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 257
- 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 359495
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3413
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 3922
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 348
- 193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 18760
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 36 (Min/Max 9/52)
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 54423524
- 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 219818948
- 240 Head_Flying_Hours 0x0032 088 088 000 Old_age Always - 310146
- 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 10782019564
- 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 17422625141
- SMART Error Log Version: 1
- ATA Error Count: 15252 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 15252 occurred at disk power-on lifetime: 5991 hours (249 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 10 00 d6 61 Error: UNC at LBA = 0x01d60010 = 30801936
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 00 d6 40 00 00:49:33.605 READ FPDMA QUEUED
- 60 08 00 80 00 d6 40 00 00:49:29.912 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:49:29.912 SET FEATURES [Reserved for Serial ATA]
- 27 00 00 00 00 00 e0 00 00:49:29.912 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 00:49:29.912 IDENTIFY DEVICE
- Error 15251 occurred at disk power-on lifetime: 5991 hours (249 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 10 00 d6 61 Error: UNC at LBA = 0x01d60010 = 30801936
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 00 d6 40 00 00:49:24.101 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:49:24.101 SET FEATURES [Reserved for Serial ATA]
- 27 00 00 00 00 00 e0 00 00:49:24.101 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 00:49:24.100 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 00:49:24.100 SET FEATURES [Set transfer mode]
- Error 15250 occurred at disk power-on lifetime: 5991 hours (249 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 10 00 d6 61 Error: UNC at LBA = 0x01d60010 = 30801936
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 00 10 00 d6 40 00 00:49:18.504 READ FPDMA QUEUED
- 60 08 00 78 00 d6 40 00 00:49:18.504 READ FPDMA QUEUED
- 60 08 00 38 00 d6 40 00 00:49:18.504 READ FPDMA QUEUED
- 60 08 00 18 00 d6 40 00 00:49:14.821 READ FPDMA QUEUED
- 60 08 00 3f 10 00 40 00 00:49:14.801 READ FPDMA QUEUED
- Error 15249 occurred at disk power-on lifetime: 5991 hours (249 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 07 00 36 62 Error: UNC at LBA = 0x02360007 = 37093383
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 01 00 07 00 36 40 00 00:48:37.842 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:48:37.842 SET FEATURES [Reserved for Serial ATA]
- 27 00 00 00 00 00 e0 00 00:48:37.842 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 00:48:37.842 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 00:48:37.841 SET FEATURES [Set transfer mode]
- Error 15248 occurred at disk power-on lifetime: 5991 hours (249 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 02 04 00 36 62 Error: UNC at LBA = 0x02360004 = 37093380
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 01 08 07 00 36 40 00 00:48:27.853 READ FPDMA QUEUED
- 60 01 00 04 00 36 40 00 00:48:27.853 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 00:48:27.853 SET FEATURES [Reserved for Serial ATA]
- 27 00 00 00 00 00 e0 00 00:48:27.853 READ NATIVE MAX ADDRESS EXT
- ec 00 00 00 00 00 a0 00 00:48:27.852 IDENTIFY DEVICE
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed: electrical failure 90% 5991 0
- # 2 Short offline Completed: electrical failure 90% 5991 0
- # 3 Short offline Completed: read failure 00% 4059 69036201
- # 4 Short offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.