- smartctl 5.42 2011-10-20 r3458 [x86_64-linux-3.2.18-std271-amd64] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: SAMSUNG SpinPoint P80
- Device Model: SAMSUNG SP0812N
- Serial Number: S00MJ10Y915503
- Firmware Version: TK100-30
- User Capacity: 80,060,424,192 bytes [80.0 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 7
- ATA Standard is: ATA/ATAPI-7 T13 1532D revision 0
- Local Time is: Fri Sep 27 00:14:27 2013 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 3000) seconds.
- Offline data collection
- capabilities: (0x1b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- No Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- No General Purpose Logging support.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 50) minutes.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 4096
- 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 1692
- 5 Reallocated_Sector_Ct 0x0033 100 100 011 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0
- 9 Power_On_Half_Minutes 0x0032 100 100 000 Old_age Always - 3389h+24m
- 10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
- 11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 908
- 194 Temperature_Celsius 0x0022 193 109 000 Old_age Always - 15
- 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 80117
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Total_Offl_Uncorrectabl 0x0030 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x000a 100 100 051 Old_age Always - 0
- 201 Soft_Read_Error_Rate 0x000a 100 100 051 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 184 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 184 occurred at disk power-on lifetime: 3388 hours (141 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 0c 00 00 00 a0 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ef 8a 0c 00 00 00 a0 00 00:00:26.938 SET FEATURES [Disable CFA power mode 1]
- Error 183 occurred at disk power-on lifetime: 3388 hours (141 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 10 51 e4 7a 8a 1c ed
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 7a 78 e4 7a 8a 1c ed 00 00:00:26.875 SEEK [RET-4]
- e1 00 00 00 00 00 a0 00 00:00:26.750 IDLE IMMEDIATE
- ef 03 45 00 10 00 a0 00 00:00:26.750 SET FEATURES [Set transfer mode]
- ef 03 0c 00 10 00 a0 00 00:00:26.750 SET FEATURES [Set transfer mode]
- c6 00 10 00 00 00 a0 00 00:00:26.750 SET MULTIPLE MODE
- Error 182 occurred at disk power-on lifetime: 3388 hours (141 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 0c 00 00 00 a0 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ef 8a 0c 00 00 00 a0 00 00:00:27.313 SET FEATURES [Disable CFA power mode 1]
- Error 181 occurred at disk power-on lifetime: 3388 hours (141 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 10 51 e4 7a 8a 1c ed
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 7a 78 e4 7a 8a 1c ed 00 00:00:27.250 SEEK [RET-4]
- e1 00 00 00 00 00 a0 00 00:00:27.125 IDLE IMMEDIATE
- ef 03 45 00 10 00 a0 00 00:00:27.125 SET FEATURES [Set transfer mode]
- ef 03 0c 00 10 00 a0 00 00:00:27.125 SET FEATURES [Set transfer mode]
- c6 00 10 00 00 00 a0 00 00:00:27.125 SET MULTIPLE MODE
- Error 180 occurred at disk power-on lifetime: 3388 hours (141 days + 4 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 04 51 0c 00 00 00 a0 Error: ABRT
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- ef 8a 0c 00 00 00 a0 00 00:00:26.875 SET FEATURES [Disable CFA power mode 1]
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 3389 -
- Device does not support Selective Self Tests/Logging