- sudo smartctl --all /dev/sda
- smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-24-generic] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.10
- Device Model: ST3250410AS
- Serial Number: 9RY0W3Q2
- Firmware Version: 3.AAC
- User Capacity: 250 059 350 016 bytes [250 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
- Local Time is: Tue Jun 10 22:02:56 2014 YEKT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- See vendor-specific Attribute list for marginal Attributes.
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 242) Self-test routine in progress...
- 20% of test remaining.
- Total time to complete Offline
- data collection: ( 430) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 64) minutes.
- SCT capabilities: (0x0001) SCT Status supported.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 117 096 006 Pre-fail Always - 138088600
- 3 Spin_Up_Time 0x0003 098 097 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 096 096 020 Old_age Always - 4833
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 18
- 7 Seek_Error_Rate 0x000f 086 060 030 Pre-fail Always - 407523045
- 9 Power_On_Hours 0x0032 074 074 000 Old_age Always - 23532
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 096 096 020 Old_age Always - 4706
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 722
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 048 045 045 Old_age Always In_the_past 52 (Min/Max 26/52)
- 194 Temperature_Celsius 0x0022 052 055 000 Old_age Always - 52 (0 16 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 068 058 000 Old_age Always - 102073169
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
- 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 727 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 727 occurred at disk power-on lifetime: 8172 hours (340 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 84 2b 20 e0 Error: UNC at LBA = 0x00202b84 = 2108292
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 d8 01 84 2b 20 e0 00 00:13:33.967 READ VERIFY SECTOR(S) EXT
- 42 d8 01 83 2b 20 e0 00 00:13:46.133 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:46.125 READ DMA EXT
- 42 d8 02 85 2b 20 e0 00 00:13:46.125 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:46.114 READ DMA EXT
- Error 726 occurred at disk power-on lifetime: 8172 hours (340 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 84 2b 20 e0 Error: UNC at LBA = 0x00202b84 = 2108292
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 d8 02 83 2b 20 e0 00 00:13:33.967 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.948 READ DMA EXT
- 42 d8 04 83 2b 20 e0 00 00:13:29.947 READ VERIFY SECTOR(S) EXT
- 42 d8 04 7f 2b 20 e0 00 00:13:29.937 READ VERIFY SECTOR(S) EXT
- 42 d8 08 87 2b 20 e0 00 00:13:29.912 READ VERIFY SECTOR(S) EXT
- Error 725 occurred at disk power-on lifetime: 8172 hours (340 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 84 2b 20 e0 Error: UNC at LBA = 0x00202b84 = 2108292
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 d8 04 83 2b 20 e0 00 00:13:33.967 READ VERIFY SECTOR(S) EXT
- 42 d8 04 7f 2b 20 e0 00 00:13:29.948 READ VERIFY SECTOR(S) EXT
- 42 d8 08 87 2b 20 e0 00 00:13:29.947 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.937 READ DMA EXT
- 42 d8 08 7f 2b 20 e0 00 00:13:29.912 READ VERIFY SECTOR(S) EXT
- Error 724 occurred at disk power-on lifetime: 8172 hours (340 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 84 2b 20 e0 Error: UNC at LBA = 0x00202b84 = 2108292
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 d8 08 7f 2b 20 e0 00 00:13:33.967 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.948 READ DMA EXT
- 42 d8 10 8f 2b 20 e0 00 00:13:29.947 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.937 READ DMA EXT
- 42 d8 10 7f 2b 20 e0 00 00:13:29.912 READ VERIFY SECTOR(S) EXT
- Error 723 occurred at disk power-on lifetime: 8172 hours (340 days + 12 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 84 2b 20 e0 Error: UNC at LBA = 0x00202b84 = 2108292
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 d8 10 7f 2b 20 e0 00 00:13:13.569 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.948 READ DMA EXT
- 42 d8 20 9f 2b 20 e0 00 00:13:29.947 READ VERIFY SECTOR(S) EXT
- 25 d8 01 00 00 00 e0 00 00:13:29.937 READ DMA EXT
- 42 d8 20 7f 2b 20 e0 00 00:13:29.912 READ VERIFY SECTOR(S) EXT
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Self-test routine in progress 20% 23532 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.