- (openvswitch-vswitchd)[root@kolla openvswitch]# cat ovs-vswitchd.log
- 2016-08-26T17:36:25.255Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log
- 2016-08-26T17:36:25.258Z|00002|ovs_numa|INFO|Discovered 28 CPU cores on NUMA node 0
- 2016-08-26T17:36:25.258Z|00003|ovs_numa|INFO|Discovered 28 CPU cores on NUMA node 1
- 2016-08-26T17:36:25.258Z|00004|ovs_numa|INFO|Discovered 2 NUMA nodes and 56 CPU cores
- 2016-08-26T17:36:25.258Z|00005|reconnect|INFO|unix:/run/openvswitch/db.sock: connecting...
- 2016-08-26T17:36:25.258Z|00006|reconnect|INFO|unix:/run/openvswitch/db.sock: connected
- 2016-08-26T17:36:25.264Z|00007|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation
- 2016-08-26T17:36:25.264Z|00008|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 1
- 2016-08-26T17:36:25.264Z|00009|ofproto_dpif|INFO|system@ovs-system: datapath does not support masked set action feature.
- 2016-08-26T17:36:25.264Z|00010|ofproto_dpif|INFO|system@ovs-system: Datapath does not support unique flow ids
- 2016-08-26T17:36:25.264Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath does not support ct_state
- 2016-08-26T17:36:25.264Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath does not support ct_zone
- 2016-08-26T17:36:25.264Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath does not support ct_mark
- 2016-08-26T17:36:25.264Z|00014|ofproto_dpif|INFO|system@ovs-system: Datapath does not support ct_label
- 2016-08-26T17:36:25.464Z|00001|ofproto_dpif_upcall(handler1)|INFO|received packet on unassociated datapath port 0
- 2016-08-26T17:36:25.467Z|00015|bridge|INFO|bridge br-ex: added interface br-ex on port 65534
- 2016-08-26T17:36:25.549Z|00016|bridge|INFO|bridge br-ex: added interface eth1 on port 1
- 2016-08-26T17:36:25.550Z|00017|bridge|INFO|bridge br-ex: using datapath ID 0000246e9602870d
- 2016-08-26T17:36:25.550Z|00018|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt"
- 2016-08-26T17:36:25.612Z|00019|bridge|INFO|ovs-vswitchd (Open vSwitch) 2.5.0
- 2016-08-26T17:36:30.833Z|00020|bridge|INFO|bridge br-int: added interface br-int on port 65534
- 2016-08-26T17:36:30.833Z|00021|bridge|INFO|bridge br-int: using datapath ID 0000fefa6e593744
- 2016-08-26T17:36:30.833Z|00022|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt"
- 2016-08-26T17:36:31.792Z|00023|connmgr|INFO|br-int: re-added service controller "punix:/var/run/openvswitch/br-int.mgmt"
- 2016-08-26T17:36:32.513Z|00024|connmgr|INFO|br-int<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:32.680Z|00025|connmgr|INFO|br-int<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:32.897Z|00026|connmgr|INFO|br-int<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:33.935Z|00027|connmgr|INFO|br-ex: re-added service controller "punix:/var/run/openvswitch/br-ex.mgmt"
- 2016-08-26T17:36:34.430Z|00028|connmgr|INFO|br-ex<->unix: 1 flow_mods in the last 0 s (1 deletes)
- 2016-08-26T17:36:34.657Z|00029|connmgr|INFO|br-ex<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:35.137Z|00030|bridge|INFO|bridge br-int: added interface int-br-ex on port 1
- 2016-08-26T17:36:35.606Z|00031|memory|INFO|246616 kB peak resident set size after 10.4 seconds
- 2016-08-26T17:36:35.606Z|00032|memory|INFO|handlers:20 ports:4 revalidators:8 rules:12 udpif keys:4
- 2016-08-26T17:36:35.607Z|00033|bridge|INFO|bridge br-ex: added interface phy-br-ex on port 2
- 2016-08-26T17:36:36.107Z|00034|connmgr|INFO|br-int<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:36.256Z|00035|connmgr|INFO|br-ex<->unix: 1 flow_mods in the last 0 s (1 adds)
- 2016-08-26T17:36:37.060Z|00036|bridge|INFO|bridge br-tun: added interface br-tun on port 65534
- 2016-08-26T17:36:37.060Z|00037|bridge|INFO|bridge br-tun: using datapath ID 0000c67bf5744442
- 2016-08-26T17:36:37.060Z|00038|connmgr|INFO|br-tun: added service controller "punix:/var/run/openvswitch/br-tun.mgmt"
- 2016-08-26T17:36:37.560Z|00039|connmgr|INFO|br-tun: re-added service controller "punix:/var/run/openvswitch/br-tun.mgmt"
- 2016-08-26T17:36:38.363Z|00040|bridge|INFO|bridge br-int: added interface patch-tun on port 2
- 2016-08-26T17:36:39.076Z|00041|bridge|INFO|bridge br-tun: added interface patch-int on port 1
- 2016-08-26T17:36:39.688Z|00042|connmgr|INFO|br-tun<->unix: 11 flow_mods in the last 0 s (11 adds)
- 2016-08-26T17:36:39.908Z|00043|connmgr|INFO|br-tun<->unix: 1 flow_mods in the last 0 s (1 adds)
- (openvswitch-vswitchd)[root@kolla openvswitch]#