- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 588
- 3 Spin_Up_Time 0x0027 177 176 021 Pre-fail Always - 4108
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 228
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 063 063 000 Old_age Always - 27094
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 225
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 116
- 193 Load_Cycle_Count 0x0032 062 062 000 Old_age Always - 416237
- 194 Temperature_Celsius 0x0022 114 089 000 Old_age Always - 33
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 9
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 1
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: read failure 10% 24628 3900776680
- # 2 Conveyance offline Completed without error 00% 24613 -
- # 3 Extended offline Completed without error 00% 20278 -
- # 4 Short offline Completed without error 00% 18818 -
- # 5 Extended offline Completed: read failure 10% 18601 3880060800
- # 6 Extended offline Completed: read failure 10% 18577 3880060800
- # 7 Extended offline Completed: read failure 10% 18545 3880060800
- # 8 Short offline Completed without error 00% 15140 -
- # 9 Extended offline Completed without error 00% 14471 -
- #10 Extended offline Completed without error 00% 12601 -
- #11 Short offline Completed without error 00% 11880 -
- #12 Short offline Completed without error 00% 11400 -
- #13 Extended offline Completed without error 00% 11261 -
- 3 of 4 failed self-tests are outdated by newer successful extended offline self-test # 3
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.