smartctl 7.4 2023-08-01 r5530 [x86_64-linux-6.8.0-31-generic] (local build) Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate IronWolf Pro Device Model: ST14000NE0008-2RX103 Serial Number: ZL2D7J98 LU WWN Device Id: 5 000c50 0c89b0647 Firmware Version: EN02 User Capacity: 14,000,519,643,136 bytes [14.0 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.3/5528 ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun May 5 08:53:58 2024 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 567) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: (1290) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x50bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 077 064 044 Pre-fail Always - 46253072 3 Spin_Up_Time 0x0003 090 088 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 099 099 020 Old_age Always - 1501 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 088 060 045 Pre-fail Always - 688439768 9 Power_On_Hours 0x0032 073 073 000 Old_age Always - 23753 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 099 099 020 Old_age Always - 1504 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 489633742965 190 Airflow_Temperature_Cel 0x0022 071 044 040 Old_age Always - 29 (Min/Max 20/29) 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1379 193 Load_Cycle_Count 0x0032 097 097 000 Old_age Always - 6748 194 Temperature_Celsius 0x0022 029 056 000 Old_age Always - 29 (0 11 0 0 0) 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 21644h+33m+31.423s 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 189699243671 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1086574289565 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. The above only provides legacy SMART information - try 'smartctl -x' for more --------------------------------------------------------------------------- === START OF INFORMATION SECTION === Model Family: Seagate IronWolf Pro Device Model: ST14000NE0008-2RX103 Serial Number: ZL2AVES1 LU WWN Device Id: 5 000c50 0c7de8eb4 Firmware Version: EN02 User Capacity: 14,000,519,643,136 bytes [14.0 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.3/5528 ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun May 5 08:56:37 2024 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 567) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: (1247) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x50bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 083 064 044 Pre-fail Always - 218224743 3 Spin_Up_Time 0x0003 091 087 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 547 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 083 060 045 Pre-fail Always - 178962910 9 Power_On_Hours 0x0032 075 075 000 Old_age Always - 22321 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 180 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 075 050 040 Old_age Always - 25 (Min/Max 25/25) 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 91 193 Load_Cycle_Count 0x0032 063 063 000 Old_age Always - 74326 194 Temperature_Celsius 0x0022 025 050 000 Old_age Always - 25 (0 11 0 0 0) 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 4 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 12496h+42m+14.822s 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 162603352618 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 162469732178 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. --------------------------------------------------------------------------------------------------------------- === START OF INFORMATION SECTION === Model Family: Seagate IronWolf Pro Device Model: ST14000NE0008-2RX103 Serial Number: ZL2CNNKP LU WWN Device Id: 5 000c50 0c8e27869 Firmware Version: EN02 User Capacity: 14,000,519,643,136 bytes [14.0 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 7200 rpm Form Factor: 3.5 inches Device is: In smartctl database 7.3/5528 ATA Version is: ACS-4 (minor revision not indicated) SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Sun May 5 09:03:17 2024 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 567) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: (1290) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x50bd) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 081 064 044 Pre-fail Always - 113281642 3 Spin_Up_Time 0x0003 092 088 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 548 5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 086 060 045 Pre-fail Always - 390970780 9 Power_On_Hours 0x0032 079 079 000 Old_age Always - 19057 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 551 18 Head_Health 0x000b 100 100 050 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 2 190 Airflow_Temperature_Cel 0x0022 080 048 040 Old_age Always - 20 (Min/Max 20/20) 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 440 193 Load_Cycle_Count 0x0032 089 089 000 Old_age Always - 23227 194 Temperature_Celsius 0x0022 020 052 000 Old_age Always - 20 (0 12 0 0 0) 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Pressure_Limit 0x0023 100 100 001 Pre-fail Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 15466h+56m+07.352s 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 178337002654 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 557170638952 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.