Advertisement
Guest User

Untitled

a guest
Mar 21st, 2018
65
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 9.30 KB | None | 0 0
  1. [root@gvo25090 ~]# smartctl -d megaraid,7 -a /dev/sda
  2. smartctl 6.2 2017-02-27 r4394 [x86_64-linux-3.10.0-714.10.2.lve1.5.12.el7.x86_64] (local build)
  3. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. /dev/sda [megaraid_disk_07] [SAT]: Device open changed type from 'megaraid,7' to 'sat+megaraid,7'
  6. === START OF INFORMATION SECTION ===
  7. Model Family: Seagate Momentus 7200.4
  8. Device Model: ST9250410AS
  9. Serial Number: 5VG3KRRM
  10. LU WWN Device Id: 5 000c50 02191acd6
  11. Firmware Version: 0002SDM1
  12. User Capacity: 250,059,350,016 bytes [250 GB]
  13. Sector Size: 512 bytes logical/physical
  14. Rotation Rate: 7200 rpm
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: ATA8-ACS T13/1699-D revision 4
  17. SATA Version is: SATA 2.6, 3.0 Gb/s
  18. Local Time is: Wed Mar 21 04:19:43 2018 CST
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: FAILED!
  24. Drive failure expected in less than 24 hours. SAVE ALL DATA.
  25. See vendor-specific Attribute list for failed Attributes.
  26.  
  27.  
  28. SMART Attributes Data Structure revision number: 10
  29. Vendor Specific SMART Attributes with Thresholds:
  30. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  31. 1 Raw_Read_Error_Rate 0x000f 117 093 006 Pre-fail Always - 144497752
  32. 3 Spin_Up_Time 0x0003 099 099 085 Pre-fail Always - 32
  33. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 171
  34. 5 Reallocated_Sector_Ct 0x0033 030 030 036 Pre-fail Always FAILING_NOW 1440
  35. 7 Seek_Error_Rate 0x000f 088 060 030 Pre-fail Always - 753959787
  36. 9 Power_On_Hours 0x0032 056 056 000 Old_age Always - 38749
  37. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  38. 12 Power_Cycle_Count 0x0032 100 037 020 Old_age Always - 171
  39. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  40. 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 707
  41. 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 68720525328
  42. 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
  43. 190 Airflow_Temperature_Cel 0x0022 071 062 045 Old_age Always - 29 (Min/Max 27/30)
  44. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 16
  45. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
  46. 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 727839
  47. 194 Temperature_Celsius 0x0022 029 040 000 Old_age Always - 29 (0 11 0 0 0)
  48. 195 Hardware_ECC_Recovered 0x001a 044 041 000 Old_age Always - 144497752
  49. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  50. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  51. 199 UDMA_CRC_Error_Count 0x403e 200 200 000 Old_age Always - 0
  52. 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 191349382979513
  53. 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1361557487
  54. 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3008385087
  55. 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
  56.  
  57. SMART Error Log Version: 1
  58. ATA Error Count: 707 (device log contains only the most recent five errors)
  59. CR = Command Register [HEX]
  60. FR = Features Register [HEX]
  61. SC = Sector Count Register [HEX]
  62. SN = Sector Number Register [HEX]
  63. CL = Cylinder Low Register [HEX]
  64. CH = Cylinder High Register [HEX]
  65. DH = Device/Head Register [HEX]
  66. DC = Device Command Register [HEX]
  67. ER = Error register [HEX]
  68. ST = Status register [HEX]
  69. Powered_Up_Time is measured from power on, and printed as
  70. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  71. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  72.  
  73. Error 707 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
  74. When the command that caused the error occurred, the device was active or idle.
  75.  
  76. After command completion occurred, registers were:
  77. ER ST SC SN CL CH DH
  78. -- -- -- -- -- -- --
  79. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  80.  
  81. Commands leading to the command that caused the error were:
  82. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  83. -- -- -- -- -- -- -- -- ---------------- --------------------
  84. 42 00 00 ff ff ff 4f 00 40d+12:12:35.762 READ VERIFY SECTOR(S) EXT
  85. 42 00 00 ff ff ff 4f 00 40d+12:12:35.500 READ VERIFY SECTOR(S) EXT
  86. 42 00 00 ff ff ff 4f 00 40d+12:12:35.415 READ VERIFY SECTOR(S) EXT
  87. 42 00 00 ff ff ff 4f 00 40d+12:12:35.066 READ VERIFY SECTOR(S) EXT
  88. 42 00 00 ff ff ff 4f 00 40d+12:12:35.030 READ VERIFY SECTOR(S) EXT
  89.  
  90. Error 706 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
  91. When the command that caused the error occurred, the device was active or idle.
  92.  
  93. After command completion occurred, registers were:
  94. ER ST SC SN CL CH DH
  95. -- -- -- -- -- -- --
  96. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  97.  
  98. Commands leading to the command that caused the error were:
  99. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  100. -- -- -- -- -- -- -- -- ---------------- --------------------
  101. 42 00 00 ff ff ff 4f 00 40d+12:12:21.776 READ VERIFY SECTOR(S) EXT
  102. 42 00 00 ff ff ff 4f 00 40d+12:12:21.545 READ VERIFY SECTOR(S) EXT
  103. 42 00 00 ff ff ff 4f 00 40d+12:12:21.348 READ VERIFY SECTOR(S) EXT
  104. 42 00 00 ff ff ff 4f 00 40d+12:12:19.925 READ VERIFY SECTOR(S) EXT
  105. 42 00 00 ff ff ff 4f 00 40d+12:12:19.752 READ VERIFY SECTOR(S) EXT
  106.  
  107. Error 705 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
  108. When the command that caused the error occurred, the device was active or idle.
  109.  
  110. After command completion occurred, registers were:
  111. ER ST SC SN CL CH DH
  112. -- -- -- -- -- -- --
  113. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  114.  
  115. Commands leading to the command that caused the error were:
  116. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  117. -- -- -- -- -- -- -- -- ---------------- --------------------
  118. 42 00 00 ff ff ff 4f 00 40d+12:12:09.157 READ VERIFY SECTOR(S) EXT
  119. 42 00 00 ff ff ff 4f 00 40d+12:12:07.822 READ VERIFY SECTOR(S) EXT
  120. 42 00 00 ff ff ff 4f 00 40d+12:12:07.732 READ VERIFY SECTOR(S) EXT
  121. 42 00 00 ff ff ff 4f 00 40d+12:12:07.704 READ VERIFY SECTOR(S) EXT
  122. 42 00 00 ff ff ff 4f 00 40d+12:12:07.544 READ VERIFY SECTOR(S) EXT
  123.  
  124. Error 704 occurred at disk power-on lifetime: 37679 hours (1569 days + 23 hours)
  125. When the command that caused the error occurred, the device was active or idle.
  126.  
  127. After command completion occurred, registers were:
  128. ER ST SC SN CL CH DH
  129. -- -- -- -- -- -- --
  130. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  131.  
  132. Commands leading to the command that caused the error were:
  133. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  134. -- -- -- -- -- -- -- -- ---------------- --------------------
  135. 42 00 00 ff ff ff 4f 00 33d+12:25:07.172 READ VERIFY SECTOR(S) EXT
  136. 42 00 00 ff ff ff 4f 00 33d+12:25:06.911 READ VERIFY SECTOR(S) EXT
  137. 42 00 00 ff ff ff 4f 00 33d+12:25:06.825 READ VERIFY SECTOR(S) EXT
  138. 42 00 00 ff ff ff 4f 00 33d+12:25:06.476 READ VERIFY SECTOR(S) EXT
  139. 42 00 00 ff ff ff 4f 00 33d+12:25:06.441 READ VERIFY SECTOR(S) EXT
  140.  
  141. Error 703 occurred at disk power-on lifetime: 37679 hours (1569 days + 23 hours)
  142. When the command that caused the error occurred, the device was active or idle.
  143.  
  144. After command completion occurred, registers were:
  145. ER ST SC SN CL CH DH
  146. -- -- -- -- -- -- --
  147. 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
  148.  
  149. Commands leading to the command that caused the error were:
  150. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  151. -- -- -- -- -- -- -- -- ---------------- --------------------
  152. 42 00 00 ff ff ff 4f 00 33d+12:24:53.162 READ VERIFY SECTOR(S) EXT
  153. 42 00 00 ff ff ff 4f 00 33d+12:24:52.923 READ VERIFY SECTOR(S) EXT
  154. 42 00 00 ff ff ff 4f 00 33d+12:24:52.725 READ VERIFY SECTOR(S) EXT
  155. 42 00 00 ff ff ff 4f 00 33d+12:24:51.754 READ VERIFY SECTOR(S) EXT
  156. 42 00 00 ff ff ff 4f 00 33d+12:24:51.278 READ VERIFY SECTOR(S) EXT
  157.  
  158. SMART Self-test log structure revision number 1
  159. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  160.  
  161.  
  162. SMART Selective self-test log data structure revision number 1
  163. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  164. 1 0 0 Not_testing
  165. 2 0 0 Not_testing
  166. 3 0 0 Not_testing
  167. 4 0 0 Not_testing
  168. 5 0 0 Not_testing
  169. Selective self-test flags (0x0):
  170. After scanning selected spans, do NOT read-scan remainder of disk.
  171. If Selective self-test is pending on power-up, resume after 0 minute delay.