- [root@gvo25090 ~]# smartctl -d megaraid,7 -a /dev/sda
- smartctl 6.2 2017-02-27 r4394 [x86_64-linux-3.10.0-714.10.2.lve1.5.12.el7.x86_64] (local build)
- Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
- /dev/sda [megaraid_disk_07] [SAT]: Device open changed type from 'megaraid,7' to 'sat+megaraid,7'
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Momentus 7200.4
- Device Model: ST9250410AS
- Serial Number: 5VG3KRRM
- LU WWN Device Id: 5 000c50 02191acd6
- Firmware Version: 0002SDM1
- User Capacity: 250,059,350,016 bytes [250 GB]
- Sector Size: 512 bytes logical/physical
- Rotation Rate: 7200 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS T13/1699-D revision 4
- SATA Version is: SATA 2.6, 3.0 Gb/s
- Local Time is: Wed Mar 21 04:19:43 2018 CST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: FAILED!
- Drive failure expected in less than 24 hours. SAVE ALL DATA.
- See vendor-specific Attribute list for failed Attributes.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 117 093 006 Pre-fail Always - 144497752
- 3 Spin_Up_Time 0x0003 099 099 085 Pre-fail Always - 32
- 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 171
- 5 Reallocated_Sector_Ct 0x0033 030 030 036 Pre-fail Always FAILING_NOW 1440
- 7 Seek_Error_Rate 0x000f 088 060 030 Pre-fail Always - 753959787
- 9 Power_On_Hours 0x0032 056 056 000 Old_age Always - 38749
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 037 020 Old_age Always - 171
- 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 707
- 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 68720525328
- 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
- 190 Airflow_Temperature_Cel 0x0022 071 062 045 Old_age Always - 29 (Min/Max 27/30)
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 16
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
- 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 727839
- 194 Temperature_Celsius 0x0022 029 040 000 Old_age Always - 29 (0 11 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 044 041 000 Old_age Always - 144497752
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x403e 200 200 000 Old_age Always - 0
- 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 191349382979513
- 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 1361557487
- 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 3008385087
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 707 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 707 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 ff ff ff 4f 00 40d+12:12:35.762 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:35.500 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:35.415 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:35.066 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:35.030 READ VERIFY SECTOR(S) EXT
- Error 706 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 ff ff ff 4f 00 40d+12:12:21.776 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:21.545 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:21.348 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:19.925 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:19.752 READ VERIFY SECTOR(S) EXT
- Error 705 occurred at disk power-on lifetime: 37849 hours (1577 days + 1 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 ff ff ff 4f 00 40d+12:12:09.157 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:07.822 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:07.732 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:07.704 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 40d+12:12:07.544 READ VERIFY SECTOR(S) EXT
- Error 704 occurred at disk power-on lifetime: 37679 hours (1569 days + 23 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 ff ff ff 4f 00 33d+12:25:07.172 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:25:06.911 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:25:06.825 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:25:06.476 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:25:06.441 READ VERIFY SECTOR(S) EXT
- Error 703 occurred at disk power-on lifetime: 37679 hours (1569 days + 23 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 ff ff ff 4f 00 33d+12:24:53.162 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:24:52.923 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:24:52.725 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:24:51.754 READ VERIFY SECTOR(S) EXT
- 42 00 00 ff ff ff 4f 00 33d+12:24:51.278 READ VERIFY SECTOR(S) EXT
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.