- Drive G
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.11.0-37-generic] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
- Sending command: "Execute SMART Extended self-test routine immediately in off-line mode".
- Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful.
- Testing has begun.
- Please wait 116 minutes for test to complete.
- Test will complete after Sat Oct 16 10:02:07 2021 EDT
- Use smartctl -X to abort test.
- hal@hal:~$ sudo smartctl -a /dev/sdg
- [sudo] password for hal:
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.11.0-37-generic] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Device Model: WL1000GSA3272C
- Serial Number: WOL240262691
- LU WWN Device Id: 5 0014ee f00abd663
- Firmware Version: 80.00A80
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Device is: Not in smartctl database [for details use: -P showall]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Sat Oct 16 10:04:58 2021 EDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (10080) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 116) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x30b5) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 1
- 3 Spin_Up_Time 0x0027 195 174 021 Pre-fail Always - 1241
- 4 Start_Stop_Count 0x0032 089 089 000 Old_age Always - 11799
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 001 001 000 Old_age Always - 75614
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 357
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 266
- 193 Load_Cycle_Count 0x0032 197 197 000 Old_age Always - 11532
- 194 Temperature_Celsius 0x0022 113 100 000 Old_age Always - 30
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 1
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 199 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Short offline Completed without error 00% 49 -
- # 2 Short offline Completed without error 00% 63069 -
- # 3 Conveyance offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.