  1. [2020/07/17 07:18:28]
  2. Ai Overclock Tuner [XMP II]
  3. XMP [XMP DDR4-3000 15-17-17-35-1.35V]
  4. BCLK Frequency [100.0000]
  5. ASUS MultiCore Enhancement [Auto – Lets BIOS Optimize]
  6. SVID Behavior [Auto]
  7. AVX Instruction Core Ratio Negative Offset [0]
  8. CPU Core Ratio [Sync All Cores]
  9. 1-Core Ratio Limit [50]
  10. DRAM Odd Ratio Mode [Enabled]
  11. DRAM Frequency [DDR4-3000MHz]
  12. Xtreme Tweaking [Enabled]
  13. CPU SVID Support [Disabled]
  14. Maximus Tweak [Auto]
  15. DRAM CAS# Latency [15]
  16. DRAM RAS# to CAS# Delay [17]
  17. DRAM RAS# ACT Time [35]
  18. DRAM Command Rate [1N]
  19. DRAM RAS# to RAS# Delay L [8]
  20. DRAM RAS# to RAS# Delay S [6]
  21. DRAM REF Cycle Time [390]
  22. DRAM REF Cycle Time 2 [240]
  23. DRAM REF Cycle Time 4 [165]
  24. DRAM Refresh Interval [Auto]
  25. DRAM WRITE Recovery Time [Auto]
  26. DRAM READ to PRE Time [Auto]
  27. DRAM FOUR ACT WIN Time [33]
  28. DRAM WRITE to READ Delay [Auto]
  29. DRAM WRITE to READ Delay L [Auto]
  30. DRAM WRITE to READ Delay S [Auto]
  31. DRAM CKE Minimum Pulse Width [Auto]
  32. DRAM Write Latency [Auto]
  33. ODT RTT WR (CHA) [Auto]
  34. ODT RTT PARK (CHA) [Auto]
  35. ODT RTT NOM (CHA) [Auto]
  36. ODT RTT WR (CHB) [Auto]
  37. ODT RTT PARK (CHB) [Auto]
  38. ODT RTT NOM (CHB) [Auto]
  39. ODT_READ_DURATION [Auto]
  40. ODT_READ_DELAY [Auto]
  41. ODT_WRITE_DURATION [Auto]
  42. ODT_WRITE_DELAY [Auto]
  43. Data Rising Slope [Auto]
  44. Data Rising Slope Offset [Auto]
  45. Cmd Rising Slope [Auto]
  46. Cmd Rising Slope Offset [Auto]
  47. Ctl Rising Slope [Auto]
  48. Ctl Rising Slope Offset [Auto]
  49. Clk Rising Slope [Auto]
  50. Clk Rising Slope Offset [Auto]
  51. Data Falling Slope [Auto]
  52. Data Falling Slope Offset [Auto]
  53. Cmd Falling Slope [Auto]
  54. Cmd Falling Slope Offset [Auto]
  55. Ctl Falling Slope [Auto]
  56. Ctl Falling Slope Offset [Auto]
  57. Clk Falling Slope [Auto]
  58. Clk Falling Slope Offset [Auto]
  59. DRAM RTL INIT value [Auto]
  60. DRAM RTL (CHA DIMM0 Rank0) [Auto]
  61. DRAM RTL (CHA DIMM0 Rank1) [Auto]
  62. DRAM RTL (CHA DIMM1 Rank0) [Auto]
  63. DRAM RTL (CHA DIMM1 Rank1) [Auto]
  64. DRAM RTL (CHB DIMM0 Rank0) [Auto]
  65. DRAM RTL (CHB DIMM0 Rank1) [Auto]
  66. DRAM RTL (CHB DIMM1 Rank0) [Auto]
  67. DRAM RTL (CHB DIMM1 Rank1) [Auto]
  68. DRAM IOL (CHA DIMM0 Rank0) [Auto]
  69. DRAM IOL (CHA DIMM0 Rank1) [Auto]
  70. DRAM IOL (CHA DIMM1 Rank0) [Auto]
  71. DRAM IOL (CHA DIMM1 Rank1) [Auto]
  72. DRAM IOL (CHB DIMM0 Rank0) [Auto]
  73. DRAM IOL (CHB DIMM0 Rank1) [Auto]
  74. DRAM IOL (CHB DIMM1 Rank0) [Auto]
  75. DRAM IOL (CHB DIMM1 Rank1) [Auto]
  76. CHA IO_Latency_offset [Auto]
  77. CHB IO_Latency_offset [Auto]
  78. CHA RFR delay [Auto]
  79. CHB RFR delay [Auto]
  80. Early Command Training [Auto]
  81. SenseAmp Offset Training [Enabled]
  82. Early ReadMPR Timing Centering 2D [Enabled]
  83. Read MPR Training [Enabled]
  84. Receive Enable Training [Enabled]
  85. Jedec Write Leveling [Enabled]
  86. Early Write Time Centering 2D [Auto]
  87. Early Read Time Centering 2D [Auto]
  88. Write Timing Centering 1D [Enabled]
  89. Write Voltage Centering 1D [Auto]
  90. Read Timing Centering 1D [Auto]
  91. Dimm ODT Training* [Auto]
  92. Max RTT_WR [ODT Off]
  93. DIMM RON Training* [Auto]
  94. Write Drive Strength/Equalization 2D* [Disabled]
  95. Write Slew Rate Training* [Auto]
  96. Read ODT Training* [Auto]
  97. Read Equalization Training* [Auto]
  98. Read Amplifier Training* [Auto]
  99. Write Timing Centering 2D [Auto]
  100. Read Timing Centering 2D [Auto]
  101. Command Voltage Centering [Auto]
  102. Write Voltage Centering 2D [Auto]
  103. Read Voltage Centering 2D [Auto]
  104. Late Command Training [Auto]
  105. Round Trip Latency [Auto]
  106. Turn Around Timing Training [Disabled]
  107. Rank Margin Tool [Disabled]
  108. Memory Test [Disabled]
  109. DIMM SPD Alias Test [Auto]
  110. Receive Enable Centering 1D [Auto]
  111. Retrain Margin Check [Disabled]
  112. Write Drive Strength Up/Dn independently [Disabled]
  113. tRDRD_sg [Auto]
  114. tRDRD_dg [Auto]
  115. tRDWR_sg [Auto]
  116. tRDWR_dg [Auto]
  117. tWRWR_sg [Auto]
  118. tWRWR_dg [Auto]
  119. tWRRD_sg [Auto]
  120. tWRRD_dg [Auto]
  121. tRDRD_dr [Auto]
  122. tRDRD_dd [Auto]
  123. tRDWR_dr [Auto]
  124. tRDWR_dd [Auto]
  125. tWRWR_dr [Auto]
  126. tWRWR_dd [Auto]
  127. tWRRD_dr [Auto]
  128. tWRRD_dd [Auto]
  129. TWRPRE [Auto]
  130. TRDPRE [Auto]
  131. tREFIX9 [Auto]
  132. OREF_RI [Auto]
  133. MRC Fast Boot [Auto]
  134. Delay after Train [Disabled]
  135. DRAM CLK Period [Auto]
  136. Memory Scrambler [Enabled]
  137. Channel A DIMM Control [Enable both DIMMs]
  138. Channel B DIMM Control [Enable both DIMMs]
  139. Trace Centering [Disabled]
  140. MCH Full Check [Auto]
  141. Training Profile [Auto]
  142. DLLBwEn [Auto]
  143. DRAM SPD Write [Disabled]
  144. XTU Setting [Auto]
  145. CPU Load-line Calibration [Level 5]
  146. Synch ACDC Loadline with VRM Loadline [Disabled]
  147. CPU Current Capability [140%]
  148. CPU VRM Switching Frequency [Auto]
  149. VRM Spread Spectrum [Disabled]
  150. Active Frequency Mode [Disabled]
  151. CPU Power Duty Control [Extreme]
  152. CPU Power Phase Control [Extreme]
  153. CPU Power Thermal Control [120]
  154. CPU VRM Thermal Control [Disabled]
  155. DRAM Current Capability [130%]
  156. DRAM Switching Frequency [Auto]
  157. CPU Core/Cache Boot Voltage [Auto]
  158. DMI Boot Voltage [Auto]
  159. Core PLL Boot Voltage [Auto]
  160. CPU System Agent Boot Voltage [Auto]
  161. CPU VCCIO Boot Voltage [Auto]
  162. PLL Termination Boot voltage [Auto]
  163. CPU Standby Boot Voltage [Auto]
  164. Intel(R) SpeedStep(tm) [Disabled]
  165. Turbo Mode [Enabled]
  166. Long Duration Package Power Limit [Auto]
  167. Package Power Time Window [Auto]
  168. Short Duration Package Power Limit [Auto]
  169. IA AC Load Line [Auto]
  170. IA DC Load Line [Auto]
  171. TVB Voltage Optimizations [Auto]
  172. Realtime Memory Timing [Disabled]
  173. FCLK Frequency for Early Power On [Auto]
  174. Initial BCLK Frequency [Auto]
  175. BCLK Amplitude [Auto]
  176. BCLK Slew Rate [Auto]
  177. BCLK Spread Spectrum [Auto]
  178. BCLK Frequency Slew Rate [Auto]
  179. DRAM VTT Voltage [Auto]
  180. VPPDDR Voltage [Auto]
  181. DMI Voltage [Auto]
  182. Core PLL Voltage [Auto]
  183. Internal PLL Voltage [Auto]
  184. GT PLL Voltage [Auto]
  185. Ring PLL Voltage [Auto]
  186. System Agent PLL Voltage [Auto]
  187. Memory Controller PLL Voltage [Auto]
  188. PLL Bandwidth [Auto]
  189. Eventual DRAM Voltage [Auto]
  190. Eventual CPU Standby Voltage [Auto]
  191. Eventual PLL Termination Voltage [Auto]
  192. Eventual DMI Voltage [Auto]
  193. Package Temperature Threshold [Auto]
  194. Regulate Frequency by above Threshold [Auto]
  195. Cooler Efficiency Customize [Stop Training]
  196. Cooler Re-evaluation Algorithm [Normal]
  197. Optimism Scale [100]
  198. CPU Core/Cache Current Limit Max. [Auto]
  199. Ring Down Bin [Auto]
  200. Min. CPU Cache Ratio [43]
  201. Max CPU Cache Ratio [43]
  202. BCLK Aware Adaptive Voltage [Enabled]
  203. CPU Core/Cache Voltage [Manual Mode]
  204. - CPU Core Voltage Override [1.250]
  205. DRAM Voltage [1.3500]
  206. CPU VCCIO Voltage [1.10000]
  207. CPU System Agent Voltage [1.10000]
  208. PLL Termination Voltage [Auto]
  209. PCH Core Voltage [1.10000]
  210. CPU Standby Voltage [Auto]
  211. DRAM CTRL REF Voltage on CHA [Auto]
  212. DRAM CTRL REF Voltage on CHB [Auto]
  213. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL0 [Auto]
  214. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL1 [Auto]
  215. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL2 [Auto]
  216. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL3 [Auto]
  217. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL4 [Auto]
  218. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL5 [Auto]
  219. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL6 [Auto]
  220. DRAM DATA REF Voltage on CHA DIMM0 Rank0 BL7 [Auto]
  221. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL0 [Auto]
  222. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL1 [Auto]
  223. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL2 [Auto]
  224. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL3 [Auto]
  225. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL4 [Auto]
  226. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL5 [Auto]
  227. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL6 [Auto]
  228. DRAM DATA REF Voltage on CHA DIMM0 Rank1 BL7 [Auto]
  229. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL0 [Auto]
  230. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL1 [Auto]
  231. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL2 [Auto]
  232. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL3 [Auto]
  233. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL4 [Auto]
  234. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL5 [Auto]
  235. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL6 [Auto]
  236. DRAM DATA REF Voltage on CHA DIMM1 Rank0 BL7 [Auto]
  237. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL0 [Auto]
  238. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL1 [Auto]
  239. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL2 [Auto]
  240. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL3 [Auto]
  241. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL4 [Auto]
  242. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL5 [Auto]
  243. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL6 [Auto]
  244. DRAM DATA REF Voltage on CHA DIMM1 Rank1 BL7 [Auto]
  245. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL0 [Auto]
  246. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL1 [Auto]
  247. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL2 [Auto]
  248. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL3 [Auto]
  249. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL4 [Auto]
  250. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL5 [Auto]
  251. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL6 [Auto]
  252. DRAM DATA REF Voltage on CHB DIMM0 Rank0 BL7 [Auto]
  253. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL0 [Auto]
  254. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL1 [Auto]
  255. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL2 [Auto]
  256. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL3 [Auto]
  257. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL4 [Auto]
  258. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL5 [Auto]
  259. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL6 [Auto]
  260. DRAM DATA REF Voltage on CHB DIMM0 Rank1 BL7 [Auto]
  261. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL0 [Auto]
  262. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL1 [Auto]
  263. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL2 [Auto]
  264. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL3 [Auto]
  265. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL4 [Auto]
  266. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL5 [Auto]
  267. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL6 [Auto]
  268. DRAM DATA REF Voltage on CHB DIMM1 Rank0 BL7 [Auto]
  269. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL0 [Auto]
  270. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL1 [Auto]
  271. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL2 [Auto]
  272. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL3 [Auto]
  273. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL4 [Auto]
  274. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL5 [Auto]
  275. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL6 [Auto]
  276. DRAM DATA REF Voltage on CHB DIMM1 Rank1 BL7 [Auto]
  277. PCI Express Native Power Management [Disabled]
  278. PCH DMI ASPM [Disabled]
  279. ASPM 0 [Disabled]
  280. L1 Substates [Disabled]
  281. PCI Express Clock Gating [Enabled]
  282. DMI Link ASPM Control [Disabled]
  283. PEG - ASPM [Disabled]
  284. Software Guard Extensions (SGX) [Software Controlled]
  285. Tcc Offset Time Window [Auto]
  286. Hardware Prefetcher [Enabled]
  287. Adjacent Cache Line Prefetch [Enabled]
  288. Intel (VMX) Virtualization Technology [Disabled]
  289. Maximum CPU Core Temperature [Auto]
  290. Active Processor Cores [All]
  291. Hyper-Threading [Enabled]
  292. Thermal Monitor [Enabled]
  293. Boot performance mode [Auto]
  294. Intel(R) SpeedStep(tm) [Disabled]
  295. Intel(R) Speed Shift Technology [Disabled]
  296. Turbo Mode [Enabled]
  297. CPU C-states [Disabled]
  298. CFG Lock [Disabled]
  299. VT-d [Disabled]
  300. Above 4G Decoding [Disabled]
  301. Memory Remap [Enabled]
  302. Primary Display [PCIE]
  303. iGPU Multi-Monitor [Disabled]
  304. DMI Max Link Speed [Gen3]
  305. PCIEX16_1 Link Speed [Gen3]
  306. PCIEX16_2 Link Speed [Auto]
  307. PCIe Speed [Gen3]
  308. SATA Controller(s) [Enabled]
  309. SATA Mode Selection [AHCI]
  310. Aggressive LPM Support [Disabled]
  311. SMART Self Test [Enabled]
  312. SATA6G_1(Black) [Enabled]
  313. SATA6G_1 Hot Plug [Disabled]
  314. SATA6G_2(Black) [Enabled]
  315. SATA6G_2 Hot Plug [Disabled]
  316. SATA6G_3(Black) [Enabled]
  317. SATA6G_3 Hot Plug [Disabled]
  318. SATA6G_4(Black) [Enabled]
  319. SATA6G_4 Hot Plug [Disabled]
  320. SATA6G_5(Black) [Enabled]
  321. SATA6G_5 Hot Plug [Disabled]
  322. SATA6G_6(Black) [Enabled]
  323. SATA6G_6 Hot Plug [Disabled]
  324. SATA6G_7(Gray) [Enabled]
  325. SATA6G_7 Hot Plug [Disabled]
  326. SATA6G_8(Gray) [Enabled]
  327. SATA6G_8 Hot Plug [Disabled]
  328. PTT [Disable]
  329. Discrete Thunderbolt(TM) Support [Disabled]
  330. HD Audio [Disabled]
  331. Intel LAN Controller [Enabled]
  332. Intel PXE Option ROM [Disabled]
  333. 5G LAN Card [Enabled]
  334. 5G LAN PXE Option ROM [Disabled]
  335. When system is in working state [All On]
  336. Q-Code LED Function [Auto]
  337. When system is in sleep, hibernate or soft off states [Stealth Mode]
  338. PCIEX16_3 Bandwidth [X2 Mode]
  339. CPU PCIE Configuration Mode [DIMM.2_1 + DIMM.2_2]
  340. USB power delivery in Soft Off state (S5) [Enabled]
  341. Front Panel USB Type C Power Mode [Auto]
  342. Back I/O USB Type C Power Mode [Auto]
  343. Connectivity mode (Wi-Fi & Bluetooth) [Disable]
  344. ErP Ready [Disabled]
  345. Restore AC Power Loss [Power Off]
  346. Power On By PCI-E [Disabled]
  347. Power On By RTC [Disabled]
  348. SR-IOV Support [Disabled]
  349. Legacy USB Support [Enabled]
  350. XHCI Hand-off [Disabled]
  351. U31G2_1 [Enabled]
  352. U31G1_E1 [Enabled]
  353. U31G1_E2 [Enabled]
  354. U31G1_E3 [Enabled]
  355. U31G1_E4 [Enabled]
  356. LAN2_U31G2_3 [Enabled]
  357. LAN2_U31G2_4 [Enabled]
  358. LAN1_U31G2_5 [Enabled]
  359. U31G2_C6 [Enabled]
  360. U31G1_7 [Enabled]
  361. U31G1_8 [Enabled]
  362. U31G1_9 [Enabled]
  363. U31G1_10 [Enabled]
  364. USB_11 [Enabled]
  365. USB_12 [Enabled]
  366. U31G1_E5 [Enabled]
  367. U31G1_E6 [Enabled]
  368. Network Stack [Enabled]
  369. Ipv4 PXE Support [Enabled]
  370. Ipv6 PXE Support [Enabled]
  371. Device [N\A]
  372. CPU Temperature [Monitor]
  373. MotherBoard Temperature [Monitor]
  374. PCH Temperature [Monitor]
  375. T Sensor Temperature [Monitor]
  376. DIMM.2 Sensor 1 Temperature [Monitor]
  377. DIMM.2 Sensor 2 Temperature [Monitor]
  378. Water In T Sensor Temperature [Monitor]
  379. Water Out T Sensor Temperature [Monitor]
  380. WB In T Sensor Temperature [Monitor]
  381. WB Out T Sensor Temperature [Monitor]
  382. EXT_Sensor1 Temperature [Monitor]
  383. EXT_Sensor2 Temperature [Monitor]
  384. EXT_Sensor3 Temperature [Monitor]
  385. CPU Fan Speed [Ignore]
  386. CPU Optional Fan Speed [Ignore]
  387. Chassis Fan 1 Speed [Monitor]
  388. Chassis Fan 2 Speed [Monitor]
  389. Radiator Fan 1 Speed [Monitor]
  390. Radiator Fan 2 Speed [Monitor]
  391. W_PUMP+ 1 Speed [Monitor]
  392. W_PUMP+ 2 Speed [Monitor]
  393. Extension Fan 1 Speed [Monitor]
  394. Extension Fan 2 Speed [Monitor]
  395. Extension Fan 3 Speed [Monitor]
  396. Flow Rate [Monitor]
  397. WB Flow Rate [Monitor]
  398. CPU Core Voltage [Monitor]
  399. 3.3V Voltage [Monitor]
  400. 5V Voltage [Monitor]
  401. 12V Voltage [Monitor]
  402. CPU Q-Fan Control [DC Mode]
  403. CPU Fan Step Up [0 sec]
  404. CPU Fan Step Down [0 sec]
  405. CPU Fan Speed Lower Limit [Ignore]
  406. CPU Fan Profile [Manual]
  407. CPU Upper Temperature [70]
  408. CPU Fan Max. Duty Cycle (%) [100]
  409. CPU Middle Temperature [45]
  410. CPU Fan Middle. Duty Cycle (%) [100]
  411. CPU Lower Temperature [40]
  412. CPU Fan Min. Duty Cycle (%) [70]
  413. Chassis Fan 1 Q-Fan Control [Auto]
  414. Chassis Fan 1 Q-Fan Source [CPU]
  415. Chassis Fan 1 Step Up [0 sec]
  416. Chassis Fan 1 Step Down [0 sec]
  417. Chassis Fan 1 Speed Low Limit [200 RPM]
  418. Chassis Fan 1 Profile [Standard]
  419. Chassis Fan 2 Q-Fan Control [Auto]
  420. Chassis Fan 2 Q-Fan Source [CPU]
  421. Chassis Fan 2 Step Up [0 sec]
  422. Chassis Fan 2 Step Down [0 sec]
  423. Chassis Fan 2 Speed Low Limit [200 RPM]
  424. Chassis Fan 2 Profile [Standard]
  425. RAD1 Fan Q-Fan Control [Auto]
  426. Radiator Fan 1 Q-Fan Source [CPU]
  427. Radiator Fan 1 Step Up [0 sec]
  428. Radiator Fan 1 Step Down [0 sec]
  429. Radiator Fan 1 Speed Low Limit [200 RPM]
  430. Radiator Fan 1 Profile [Standard]
  431. RAD2 Fan Q-Fan Control [Auto]
  432. Radiator Fan 2 Q-Fan Source [CPU]
  433. Radiator Fan 2 Step Up [0 sec]
  434. Radiator Fan 2 Step Down [0 sec]
  435. Radiator Fan 2 Speed Low Limit [200 RPM]
  436. Radiator Fan 2 Profile [Standard]
  437. Extension Fan 1 Q-Fan Control [DC Mode]
  438. Extension Fan 1 Q-Fan Source [CPU]
  439. Extension Fan 1 Speed Low Limit [200 RPM]
  440. Extension Fan 1 Profile [Standard]
  441. Extension Fan 2 Q-Fan Control [DC Mode]
  442. Extension Fan 2 Q-Fan Source [CPU]
  443. Extension Fan 2 Speed Low Limit [200 RPM]
  444. Extension Fan 2 Profile [Standard]
  445. Extension Fan 3 Q-Fan Control [DC Mode]
  446. Extension Fan 3 Q-Fan Source [CPU]
  447. Extension Fan 3 Speed Low Limit [200 RPM]
  448. Extension Fan 3 Profile [Standard]
  449. WATER PUMP+ 1 Control [Disabled]
  450. WATER PUMP+ 2 Control [Disabled]
  451. CPU Temperature LED Switch [Enabled]
  452. Firmware Configuration [Test]
  453. Type C Support [Platform-POR]
  454. Fast Boot [Enabled]
  455. Next Boot after AC Power Loss [Normal Boot]
  456. Boot Logo Display [Enabled]
  457. POST Delay Time [3 sec]
  458. Bootup NumLock State [On]
  459. Wait For 'F1' If Error [Enabled]
  460. Option ROM Messages [Force BIOS]
  461. Interrupt 19 Capture [Disabled]
  462. Setup Mode [Advanced Mode]
  463. Boot Sector (MBR/GPT) Recovery Policy [Local User Control]
  464. Next Boot Recovery Action [Skip]
  465. Launch CSM [Disabled]
  466. OS Type [Windows UEFI mode]
  467. AMI Native NVMe Driver Support [Enabled]
  468. Setup Animator [Disabled]
  469. Load from Profile [1]
  470. Profile Name [1.352 igpu ]
  471. Save to Profile [1]
  472. DIMM Slot Number [DIMM_A1]
  473. Download & Install ARMOURY CRATE app [Enabled]
  474. Bus Interface [PCIEX16_1]