Advertisement
Guest User

Untitled

a guest
May 23rd, 2019
145
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 15.39 KB | None | 0 0
  1. [root@hpc2ceph1 Linux]# /opt/MegaRAID/storcli/storcli64 /c0 show all
  2. Generating detailed summary of the adapter, it may take a while to complete.
  3.  
  4. CLI Version = 007.0916.0000.0000 Apr 05, 2019
  5. Operating system = Linux 3.10.0-957.el7.x86_64
  6. Controller = 0
  7. Status = Success
  8. Description = None
  9.  
  10.  
  11. Basics :
  12. ======
  13. Controller = 0
  14. Model = PRAID EP540i
  15. Serial Number = SP75021216
  16. Current Controller Date/Time = 05/13/2019, 11:27:13
  17. Current System Date/time = 05/13/2019, 11:27:13
  18. SAS Address = 500605b00dab1ff0
  19. PCI Address = 00:b3:00:00
  20. Mfg Date = 12/21/17
  21. Rework Date = 00/00/00
  22. Revision No = 53006
  23.  
  24.  
  25. Version :
  26. =======
  27. Firmware Package Build = 50.3.4-1169
  28. Firmware Version = 5.030.00-1321
  29. CPLD Version = 07209-021
  30. SBR Version = 5.0300.07-349
  31. Boot Block Version = 7.02.00.00-0017
  32. Bios Version = 7.03.02.2_4.17.08.00_0x07030401
  33. NVDATA Version = 5.0300.07-0037
  34. Driver Name = megaraid_sas
  35. Driver Version = 07.705.02.00-rh1
  36.  
  37.  
  38. Bus :
  39. ===
  40. Vendor Id = 0x1000
  41. Device Id = 0x14
  42. SubVendor Id = 0x1734
  43. SubDevice Id = 0x1236
  44. Host Interface = PCI-E
  45. Device Interface = SAS-12G
  46. Bus Number = 179
  47. Device Number = 0
  48. Function Number = 0
  49.  
  50.  
  51. Pending Images in Flash :
  52. =======================
  53. Image name = No pending images
  54.  
  55.  
  56. Status :
  57. ======
  58. Controller Status = Optimal
  59. Memory Correctable Errors = 0
  60. Memory Uncorrectable Errors = 0
  61. ECC Bucket Count = 0
  62. Any Offline VD Cache Preserved = No
  63. BBU Status = NA
  64. PD Firmware Download in progress = No
  65. Support PD Firmware Download = No
  66. Lock Key Assigned = No
  67. Failed to get lock key on bootup = No
  68. Lock key has not been backed up = No
  69. Bios was not detected during boot = No
  70. Controller must be rebooted to complete security operation = No
  71. A rollback operation is in progress = No
  72. At least one PFK exists in NVRAM = No
  73. SSC Policy is WB = No
  74. Controller has booted into safe mode = No
  75. Controller shutdown required = No
  76. Current Personality = RAID-Mode
  77.  
  78.  
  79. Supported Adapter Operations :
  80. ============================
  81. Rebuild Rate = Yes
  82. CC Rate = Yes
  83. BGI Rate = Yes
  84. Reconstruction Rate = Yes
  85. Patrol Read Rate = Yes
  86. Alarm Control = Yes
  87. Cluster Support = No
  88. BBU = NA
  89. Spanning = Yes
  90. Dedicated Hot Spare = Yes
  91. Revertible Hot Spares = Yes
  92. Foreign Config Import = Yes
  93. Self Diagnostic = Yes
  94. Allow Mixed Redundancy on Array = No
  95. Global Hot Spares = Yes
  96. Deny SCSI Passthrough = No
  97. Deny SMP Passthrough = No
  98. Deny STP Passthrough = No
  99. Support more than 8 Phys = Yes
  100. FW and Event Time in GMT = No
  101. Support Enhanced Foreign Import = Yes
  102. Support Enclosure Enumeration = Yes
  103. Support Allowed Operations = Yes
  104. Abort CC on Error = Yes
  105. Support Multipath = Yes
  106. Support Odd & Even Drive count in RAID1E = No
  107. Support Security = Yes
  108. Support Config Page Model = Yes
  109. Support the OCE without adding drives = Yes
  110. Support EKM = Yes
  111. Snapshot Enabled = No
  112. Support PFK = Yes
  113. Support PI = No
  114. Support Ld BBM Info = No
  115. Support Shield State = Yes
  116. Block SSD Write Disk Cache Change = No
  117. Support Suspend Resume BG ops = Yes
  118. Support Emergency Spares = No
  119. Support Set Link Speed = Yes
  120. Support Boot Time PFK Change = No
  121. Support JBOD = Yes
  122. Disable Online PFK Change = No
  123. Support Perf Tuning = Yes
  124. Support SSD PatrolRead = Yes
  125. Real Time Scheduler = Yes
  126. Support Reset Now = Yes
  127. Support Emulated Drives = Yes
  128. Headless Mode = Yes
  129. Dedicated HotSpares Limited = No
  130. Point In Time Progress = Yes
  131. Extended LD = Yes
  132. Support Uneven span = No
  133. Support Config Auto Balance = No
  134. Support Maintenance Mode = No
  135. Support Diagnostic results = Yes
  136. Support Ext Enclosure = Yes
  137. Support Sesmonitoring = Yes
  138. Support SecurityonJBOD = Yes
  139. Support ForceFlash = Yes
  140. Support DisableImmediateIO = Yes
  141. Support LargeIOSupport = Yes
  142. Support DrvActivityLEDSetting = Yes
  143. Support FlushWriteVerify = Yes
  144. Support CPLDUpdate = Yes
  145. Support ForceTo512e = Yes
  146. Support discardCacheDuringLDDelete = No
  147. Support JBOD Write cache = No
  148. Support Large QD Support = No
  149. Support Ctrl Info Extended = Yes
  150. Support IButton less = Yes
  151. Support AES Encryption Algorithm = No
  152. Support Encrypted MFC = Yes
  153. Support Snapdump = No
  154. Support Force Personality Change = No
  155. Support Dual Fw Image = No
  156. Support PSOC Update = No
  157. Support Secure Boot = No
  158. Support Clear Snapdump = No
  159. Support Debug Queue = Yes
  160. Support Least Latency Mode = Yes
  161. Support OnDemand Snapdump = No
  162.  
  163.  
  164. Enterprise Key management :
  165. =========================
  166. Capability = Supported
  167. Boot Agent = Not Available
  168. Configured = No
  169.  
  170.  
  171. Supported PD Operations :
  172. =======================
  173. Force Online = Yes
  174. Force Offline = Yes
  175. Force Rebuild = Yes
  176. Deny Force Failed = No
  177. Deny Force Good/Bad = No
  178. Deny Missing Replace = No
  179. Deny Clear = No
  180. Deny Locate = No
  181. Support Power State = Yes
  182. Set Power State For Cfg = No
  183. Support T10 Power State = No
  184. Support Temperature = Yes
  185. NCQ = Yes
  186. Support Max Rate SATA = No
  187. Support Degraded Media = Yes
  188. Support Parallel FW Update = No
  189. Support Drive Crypto Erase = Yes
  190. Support SSD Wear Gauge = No
  191.  
  192.  
  193. Supported VD Operations :
  194. =======================
  195. Read Policy = Yes
  196. Write Policy = Yes
  197. IO Policy = Yes
  198. Access Policy = Yes
  199. Disk Cache Policy = Yes
  200. Reconstruction = Yes
  201. Deny Locate = No
  202. Deny CC = No
  203. Allow Ctrl Encryption = Yes
  204. Enable LDBBM = Yes
  205. Support FastPath = Yes
  206. Performance Metrics = Yes
  207. Power Savings = No
  208. Support Powersave Max With Cache = No
  209. Support Breakmirror = Yes
  210. Support SSC WriteBack = No
  211. Support SSC Association = No
  212. Support VD Hide = Yes
  213. Support VD Cachebypass = Yes
  214. Support VD discardCacheDuringLDDelete = No
  215. Support VD Scsi Unmap = No
  216.  
  217.  
  218. Advanced Software Option :
  219. ========================
  220.  
  221. -----------------------------------------
  222. Adv S/W Opt Time Remaining Mode
  223. -----------------------------------------
  224. MegaRAID FastPath Unlimited -
  225. MegaRAID SafeStore Unlimited -
  226. MegaRAID RAID6 Unlimited -
  227. MegaRAID RAID5 Unlimited -
  228. -----------------------------------------
  229.  
  230. Safe ID = QBUW7ABICU5AC3LGUCG16R22UPQWW8GBG7JQT2RZ
  231.  
  232. HwCfg :
  233. =====
  234. ChipRevision = B0
  235. BatteryFRU = N/A
  236. Front End Port Count = 0
  237. Backend Port Count = 17
  238. BBU = Absent
  239. Alarm = Disable
  240. Serial Debugger = Present
  241. NVRAM Size = 128KB
  242. Flash Size = 16MB
  243. On Board Memory Size = 4096MB
  244. CacheVault Flash Size = NA
  245. TPM = Absent
  246. Upgrade Key = Absent
  247. On Board Expander = Absent
  248. Temperature Sensor for ROC = Present
  249. Temperature Sensor for Controller = Absent
  250. Upgradable CPLD = Present
  251. Upgradable PSOC = Absent
  252. Current Size of CacheCade (GB) = 0
  253. Current Size of FW Cache (MB) = 3183
  254. ROC temperature(Degree Celsius) = 71
  255.  
  256.  
  257. Policies :
  258. ========
  259.  
  260. Policies Table :
  261. ==============
  262.  
  263. ------------------------------------------------
  264. Policy Current Default
  265. ------------------------------------------------
  266. Predictive Fail Poll Interval 300 sec
  267. Interrupt Throttle Active Count 16
  268. Interrupt Throttle Completion 50 us
  269. Rebuild Rate 30 % 30%
  270. PR Rate 20 % 30%
  271. BGI Rate 30 % 30%
  272. Check Consistency Rate 30 % 30%
  273. Reconstruction Rate 30 % 30%
  274. Cache Flush Interval 4s
  275. ------------------------------------------------
  276.  
  277. Flush Time(Default) = 4s
  278. Drive Coercion Mode = none
  279. Auto Rebuild = On
  280. Battery Warning = On
  281. ECC Bucket Size = 15
  282. ECC Bucket Leak Rate (hrs) = 24
  283. Restore Hot Spare on Insertion = On
  284. Expose Enclosure Devices = Off
  285. Maintain PD Fail History = On
  286. Reorder Host Requests = On
  287. Auto detect BackPlane = SGPIO/i2c SEP
  288. Load Balance Mode = Auto
  289. Security Key Assigned = Off
  290. Disable Online Controller Reset = Off
  291. Use drive activity for locate = Off
  292.  
  293.  
  294. Boot :
  295. ====
  296. BIOS Enumerate VDs = 1
  297. Stop BIOS on Error = Off
  298. Delay during POST = 0
  299. Spin Down Mode = None
  300. Enable Ctrl-R = Yes
  301. Enable Web BIOS = No
  302. Enable PreBoot CLI = No
  303. Enable BIOS = Yes
  304. Max Drives to Spinup at One Time = 2
  305. Maximum number of direct attached drives to spin up in 1 min = 60
  306. Delay Among Spinup Groups (sec) = 2
  307. Allow Boot with Preserved Cache = Off
  308.  
  309.  
  310. High Availability :
  311. =================
  312. Topology Type = None
  313. Cluster Permitted = No
  314. Cluster Active = No
  315.  
  316.  
  317. Defaults :
  318. ========
  319. Phy Polarity = 0
  320. Phy PolaritySplit = 0
  321. Strip Size = 256 KB
  322. Write Policy = WB
  323. Read Policy = RA
  324. Cache When BBU Bad = Off
  325. Cached IO = Off
  326. VD PowerSave Policy = Controller Defined
  327. Default spin down time (mins) = 30
  328. Coercion Mode = None
  329. ZCR Config = Unknown
  330. Max Chained Enclosures = 3
  331. Direct PD Mapping = No
  332. Restore Hot Spare on Insertion = Yes
  333. Expose Enclosure Devices = No
  334. Maintain PD Fail History = Yes
  335. Zero Based Enclosure Enumeration = No
  336. Disable Puncturing = No
  337. EnableLDBBM = Yes
  338. DisableHII = No
  339. Un-Certified Hard Disk Drives = Allow
  340. SMART Mode = Mode 6
  341. Enable LED Header = No
  342. LED Show Drive Activity = Yes
  343. Dirty LED Shows Drive Activity = No
  344. EnableCrashDump = Yes
  345. Disable Online Controller Reset = No
  346. Treat Single span R1E as R10 = No
  347. Power Saving option = Enabled
  348. TTY Log In Flash = Yes
  349. Auto Enhanced Import = No
  350. BreakMirror RAID Support = single span R1
  351. Disable Join Mirror = Yes
  352. Enable Shield State = Yes
  353. Time taken to detect CME = 60 sec
  354.  
  355.  
  356. Capabilities :
  357. ============
  358. Supported Drives = SAS, SATA
  359. RAID Level Supported = RAID0, RAID1(2 or more drives), RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60
  360. Enable JBOD = Yes
  361. Mix in Enclosure = Allowed
  362. Mix of SAS/SATA of HDD type in VD = Not Allowed
  363. Mix of SAS/SATA of SSD type in VD = Not Allowed
  364. Mix of SSD/HDD in VD = Not Allowed
  365. SAS Disable = No
  366. Max Arms Per VD = 32
  367. Max Spans Per VD = 8
  368. Max Arrays = 240
  369. Max VD per array = 16
  370. Max Number of VDs = 64
  371. Max Parallel Commands = 4077
  372. Max SGE Count = 60
  373. Max Data Transfer Size = 8192 sectors
  374. Max Strips PerIO = 42
  375. Max Configurable CacheCade Size(GB) = 0
  376. Max Transportable DGs = 0
  377. Enable Snapdump = No
  378. Enable SCSI Unmap = Yes
  379. FDE Drive Mix Support = No
  380. Min Strip Size = 64 KB
  381. Max Strip Size = 1.000 MB
  382.  
  383.  
  384. Scheduled Tasks :
  385. ===============
  386. Consistency Check Reoccurrence = 168 hrs
  387. Next Consistency check launch = NA
  388. Patrol Read Reoccurrence = 168 hrs
  389. Next Patrol Read launch = 05/18/2019, 03:00:00
  390. Battery learn Reoccurrence = NA
  391. Next Battery Learn = NA
  392. OEMID = FSC
  393.  
  394. Drive Groups = 1
  395.  
  396. TOPOLOGY :
  397. ========
  398.  
  399. -----------------------------------------------------------------------------
  400. DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
  401. -----------------------------------------------------------------------------
  402. 0 - - - - RAID1 Optl N 223.062 GB dsbl N N none N N
  403. 0 0 - - - RAID1 Optl N 223.062 GB dsbl N N none N N
  404. 0 0 0 134:10 30 DRIVE Onln N 223.062 GB dsbl N N none - N
  405. 0 0 1 134:11 31 DRIVE Onln N 223.062 GB dsbl N N none - N
  406. -----------------------------------------------------------------------------
  407.  
  408. DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
  409. DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
  410. Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
  411. PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
  412. DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
  413. TR=Transport Ready
  414.  
  415. Virtual Drives = 1
  416.  
  417. VD LIST :
  418. =======
  419.  
  420. ---------------------------------------------------------------
  421. DG/VD TYPE State Access Consist Cache Cac sCC Size Name
  422. ---------------------------------------------------------------
  423. 0/0 RAID1 Optl RW Yes RWTD - OFF 223.062 GB
  424. ---------------------------------------------------------------
  425.  
  426. EID=Enclosure Device ID| VD=Virtual Drive| DG=Drive Group|Rec=Recovery
  427. Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
  428. Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
  429. Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
  430. AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
  431. Check Consistency
  432.  
  433. JBOD Drives = 14
  434.  
  435. JBOD LIST :
  436. =========
  437.  
  438. ---------------------------------------------------------------------------------------
  439. EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
  440. ---------------------------------------------------------------------------------------
  441. 64:0 28 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  442. 64:1 24 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  443. 64:2 26 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  444. 64:3 29 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  445. 64:4 22 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  446. 64:5 21 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  447. 64:6 25 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  448. 64:7 18 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  449. 64:8 19 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  450. 64:9 20 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  451. 64:10 23 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  452. 64:11 27 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  453. 134:8 16 JBOD - 894.252 GB SATA SSD N N 512B Micron_5200_MTFDDAK960TDC U -
  454. 134:9 17 JBOD - 894.252 GB SATA SSD N N 512B Micron_5200_MTFDDAK960TDC U -
  455. ---------------------------------------------------------------------------------------
  456.  
  457. EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|Onln=Online|
  458. Offln=Offline|Intf=Interface|Med=Media Type|SeSz=Sector Size
  459.  
  460. Physical Drives = 16
  461.  
  462. PD LIST :
  463. =======
  464.  
  465. ---------------------------------------------------------------------------------------
  466. EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
  467. ---------------------------------------------------------------------------------------
  468. 64:0 28 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  469. 64:1 24 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  470. 64:2 26 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  471. 64:3 29 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  472. 64:4 22 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  473. 64:5 21 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  474. 64:6 25 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  475. 64:7 18 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  476. 64:8 19 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  477. 64:9 20 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  478. 64:10 23 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  479. 64:11 27 JBOD - 3.638 TB SATA HDD N N 512B ST4000NM0035-1V4107 U -
  480. 134:8 16 JBOD - 894.252 GB SATA SSD N N 512B Micron_5200_MTFDDAK960TDC U -
  481. 134:9 17 JBOD - 894.252 GB SATA SSD N N 512B Micron_5200_MTFDDAK960TDC U -
  482. 134:10 30 Onln 0 223.062 GB SATA SSD N N 512B Micron_5100_MTFDDAK240TCB U -
  483. 134:11 31 Onln 0 223.062 GB SATA SSD N N 512B Micron_5100_MTFDDAK240TCB U -
  484. ---------------------------------------------------------------------------------------
  485.  
  486. EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
  487. DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
  488. UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
  489. Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
  490. SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
  491. UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
  492. CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
  493. UBUnsp=UBad Unsupported
  494.  
  495.  
  496.  
  497. [root@hpc2ceph1 Linux]#