daily pastebin goal
15%
SHARE
TWEET

Untitled

a guest Nov 7th, 2017 89 Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
  1. ubuntu@ubuntu:~/Downloads/ide$ sudo smartctl -a /dev/sda1
  2. smartctl 6.5 2016-01-24 r4214 [i686-linux-4.10.0-28-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family:     Toshiba 2.5" HDD MQ01ABD...
  7. Device Model:     TOSHIBA MQ01ABD100
  8. Serial Number:    45GPTOLQT
  9. LU WWN Device Id: 5 000039 631c025f5
  10. Firmware Version: AX0P2D
  11. User Capacity:    1,000,204,886,016 bytes [1.00 TB]
  12. Sector Sizes:     512 bytes logical, 4096 bytes physical
  13. Rotation Rate:    5400 rpm
  14. Form Factor:      2.5 inches
  15. Device is:        In smartctl database [for details use: -P show]
  16. ATA Version is:   ATA8-ACS (minor revision not indicated)
  17. SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  18. Local Time is:    Tue Nov  7 17:58:19 2017 UTC
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: PASSED
  24.  
  25. General SMART Values:
  26. Offline data collection status:  (0x00) Offline data collection activity
  27.                     was never started.
  28.                     Auto Offline Data Collection: Disabled.
  29. Self-test execution status:      ( 112) The previous self-test completed having
  30.                     the read element of the test failed.
  31. Total time to complete Offline
  32. data collection:        (  120) seconds.
  33. Offline data collection
  34. capabilities:            (0x5b) SMART execute Offline immediate.
  35.                     Auto Offline data collection on/off support.
  36.                     Suspend Offline collection upon new
  37.                     command.
  38.                     Offline surface scan supported.
  39.                     Self-test supported.
  40.                     No Conveyance Self-test supported.
  41.                     Selective Self-test supported.
  42. SMART capabilities:            (0x0003) Saves SMART data before entering
  43.                     power-saving mode.
  44.                     Supports SMART auto save timer.
  45. Error logging capability:        (0x01) Error logging supported.
  46.                     General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time:    (   2) minutes.
  49. Extended self-test routine
  50. recommended polling time:    ( 236) minutes.
  51. SCT capabilities:          (0x003d) SCT Status supported.
  52.                     SCT Error Recovery Control supported.
  53.                     SCT Feature Control supported.
  54.                     SCT Data Table supported.
  55.  
  56. SMART Attributes Data Structure revision number: 128
  57. Vendor Specific SMART Attributes with Thresholds:
  58. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  59.   1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  60.   3 Spin_Up_Time            0x0027   100   100   001    Pre-fail  Always       -       1688
  61.   5 Reallocated_Sector_Ct   0x0033   100   100   050    Pre-fail  Always       -       8
  62.   9 Power_On_Hours          0x0032   082   082   000    Old_age   Always       -       7384
  63.  12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       1389
  64. 191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       103
  65. 192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       161
  66. 193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       6158
  67. 194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       34 (Min/Max 13/43)
  68. 199 UDMA_CRC_Error_Count    0x0032   100   100   000    Old_age   Always       -       116447261
  69. 200 Multi_Zone_Error_Rate   0x0032   100   100   000    Old_age   Always       -       482610398
  70. 240 Head_Flying_Hours       0x0032   085   085   000    Old_age   Always       -       6167
  71. 241 Total_LBAs_Written      0x0032   100   100   000    Old_age   Always       -       21288223129
  72. 242 Total_LBAs_Read         0x0032   100   100   000    Old_age   Always       -       19795986335
  73. 254 Free_Fall_Sensor        0x0032   100   100   000    Old_age   Always       -       0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 5141 (device log contains only the most recent five errors)
  77.     CR = Command Register [HEX]
  78.     FR = Features Register [HEX]
  79.     SC = Sector Count Register [HEX]
  80.     SN = Sector Number Register [HEX]
  81.     CL = Cylinder Low Register [HEX]
  82.     CH = Cylinder High Register [HEX]
  83.     DH = Device/Head Register [HEX]
  84.     DC = Device Command Register [HEX]
  85.     ER = Error register [HEX]
  86.     ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 5141 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  92.   When the command that caused the error occurred, the device was active or idle.
  93.  
  94.   After command completion occurred, registers were:
  95.   ER ST SC SN CL CH DH
  96.   -- -- -- -- -- -- --
  97.   40 41 d8 b8 09 00 40  Error: UNC at LBA = 0x000009b8 = 2488
  98.  
  99.   Commands leading to the command that caused the error were:
  100.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  101.   -- -- -- -- -- -- -- --  ----------------  --------------------
  102.   60 08 d8 b8 09 00 40 00      01:15:25.177  READ FPDMA QUEUED
  103.   ef 10 02 00 00 00 a0 00      01:15:25.174  SET FEATURES [Enable SATA feature]
  104.   27 00 00 00 00 00 e0 00      01:15:25.174  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  105.   ec 00 00 00 00 00 a0 00      01:15:25.173  IDENTIFY DEVICE
  106.   ef 03 45 00 00 00 a0 00      01:15:25.173  SET FEATURES [Set transfer mode]
  107.  
  108. Error 5140 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  109.   When the command that caused the error occurred, the device was active or idle.
  110.  
  111.   After command completion occurred, registers were:
  112.   ER ST SC SN CL CH DH
  113.   -- -- -- -- -- -- --
  114.   40 41 48 b8 09 00 40  Error: UNC at LBA = 0x000009b8 = 2488
  115.  
  116.   Commands leading to the command that caused the error were:
  117.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  118.   -- -- -- -- -- -- -- --  ----------------  --------------------
  119.   60 08 48 b8 09 00 40 00      01:15:21.412  READ FPDMA QUEUED
  120.   60 08 40 b0 09 00 40 00      01:15:21.412  READ FPDMA QUEUED
  121.   60 08 38 a8 09 00 40 00      01:15:21.412  READ FPDMA QUEUED
  122.   60 08 30 a0 09 00 40 00      01:15:21.412  READ FPDMA QUEUED
  123.   60 08 28 98 09 00 40 00      01:15:21.412  READ FPDMA QUEUED
  124.  
  125. Error 5139 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  126.   When the command that caused the error occurred, the device was active or idle.
  127.  
  128.   After command completion occurred, registers were:
  129.   ER ST SC SN CL CH DH
  130.   -- -- -- -- -- -- --
  131.   40 41 d8 b8 09 00 40  Error: UNC at LBA = 0x000009b8 = 2488
  132.  
  133.   Commands leading to the command that caused the error were:
  134.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  135.   -- -- -- -- -- -- -- --  ----------------  --------------------
  136.   60 80 d8 80 08 00 40 00      01:15:17.628  READ FPDMA QUEUED
  137.   60 38 d0 40 08 00 40 00      01:15:17.628  READ FPDMA QUEUED
  138.   60 08 c8 10 08 00 40 00      01:15:17.628  READ FPDMA QUEUED
  139.   60 18 c0 20 08 00 40 00      01:15:17.628  READ FPDMA QUEUED
  140.   60 08 b8 78 08 00 40 00      01:15:17.628  READ FPDMA QUEUED
  141.  
  142. Error 5138 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  143.   When the command that caused the error occurred, the device was active or idle.
  144.  
  145.   After command completion occurred, registers were:
  146.   ER ST SC SN CL CH DH
  147.   -- -- -- -- -- -- --
  148.   40 41 80 b8 09 00 40  Error: UNC at LBA = 0x000009b8 = 2488
  149.  
  150.   Commands leading to the command that caused the error were:
  151.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  152.   -- -- -- -- -- -- -- --  ----------------  --------------------
  153.   60 08 80 b8 09 00 40 00      01:15:13.052  READ FPDMA QUEUED
  154.   60 20 78 88 08 00 40 00      01:15:13.052  READ FPDMA QUEUED
  155.   60 38 70 48 08 00 40 00      01:15:13.052  READ FPDMA QUEUED
  156.   60 28 68 18 08 00 40 00      01:15:13.052  READ FPDMA QUEUED
  157.   60 10 60 00 08 00 40 00      01:15:13.052  READ FPDMA QUEUED
  158.  
  159. Error 5137 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  160.   When the command that caused the error occurred, the device was active or idle.
  161.  
  162.   After command completion occurred, registers were:
  163.   ER ST SC SN CL CH DH
  164.   -- -- -- -- -- -- --
  165.   40 41 20 b8 09 00 40  Error: UNC at LBA = 0x000009b8 = 2488
  166.  
  167.   Commands leading to the command that caused the error were:
  168.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  169.   -- -- -- -- -- -- -- --  ----------------  --------------------
  170.   60 08 20 b8 09 00 40 00      01:15:09.278  READ FPDMA QUEUED
  171.   60 08 18 b0 09 00 40 00      01:15:09.277  READ FPDMA QUEUED
  172.   60 08 10 a8 09 00 40 00      01:15:09.277  READ FPDMA QUEUED
  173.   60 08 08 a0 09 00 40 00      01:15:09.277  READ FPDMA QUEUED
  174.   60 08 00 98 09 00 40 00      01:15:09.277  READ FPDMA QUEUED
  175.  
  176. SMART Self-test log structure revision number 1
  177. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  178. # 1  Short offline       Completed: read failure       00%      7384         133944552
  179. # 2  Extended offline    Aborted by host               90%      7384         -
  180. # 3  Short offline       Completed without error       00%      7355         -
  181. # 4  Short offline       Completed without error       00%         0         -
  182.  
  183. SMART Selective self-test log data structure revision number 1
  184.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  185.     1        0        0  Not_testing
  186.     2        0        0  Not_testing
  187.     3        0        0  Not_testing
  188.     4        0        0  Not_testing
  189.     5        0        0  Not_testing
  190. Selective self-test flags (0x0):
  191.   After scanning selected spans, do NOT read-scan remainder of disk.
  192. If Selective self-test is pending on power-up, resume after 0 minute delay.
RAW Paste Data