  1. ubuntu@ubuntu:~/Downloads/ide$ sudo smartctl -a /dev/sda1
  2. smartctl 6.5 2016-01-24 r4214 [i686-linux-4.10.0-28-generic] (local build)
  3. Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: Toshiba 2.5" HDD MQ01ABD...
  7. Device Model: TOSHIBA MQ01ABD100
  8. Serial Number: 45GPTOLQT
  9. LU WWN Device Id: 5 000039 631c025f5
  10. Firmware Version: AX0P2D
  11. User Capacity: 1,000,204,886,016 bytes [1.00 TB]
  12. Sector Sizes: 512 bytes logical, 4096 bytes physical
  13. Rotation Rate: 5400 rpm
  14. Form Factor: 2.5 inches
  15. Device is: In smartctl database [for details use: -P show]
  16. ATA Version is: ATA8-ACS (minor revision not indicated)
  17. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  18. Local Time is: Tue Nov 7 17:58:19 2017 UTC
  19. SMART support is: Available - device has SMART capability.
  20. SMART support is: Enabled
  21.  
  22. === START OF READ SMART DATA SECTION ===
  23. SMART overall-health self-assessment test result: PASSED
  24.  
  25. General SMART Values:
  26. Offline data collection status: (0x00) Offline data collection activity
  27. was never started.
  28. Auto Offline Data Collection: Disabled.
  29. Self-test execution status: ( 112) The previous self-test completed having
  30. the read element of the test failed.
  31. Total time to complete Offline
  32. data collection: ( 120) seconds.
  33. Offline data collection
  34. capabilities: (0x5b) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. Offline surface scan supported.
  39. Self-test supported.
  40. No Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 2) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 236) minutes.
  51. SCT capabilities: (0x003d) SCT Status supported.
  52. SCT Error Recovery Control supported.
  53. SCT Feature Control supported.
  54. SCT Data Table supported.
  55.  
  56. SMART Attributes Data Structure revision number: 128
  57. Vendor Specific SMART Attributes with Thresholds:
  58. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  59. 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  60. 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1688
  61. 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 8
  62. 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7384
  63. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1389
  64. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 103
  65. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 161
  66. 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 6158
  67. 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 34 (Min/Max 13/43)
  68. 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 116447261
  69. 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 482610398
  70. 240 Head_Flying_Hours 0x0032 085 085 000 Old_age Always - 6167
  71. 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 21288223129
  72. 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 19795986335
  73. 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 5141 (device log contains only the most recent five errors)
  77. CR = Command Register [HEX]
  78. FR = Features Register [HEX]
  79. SC = Sector Count Register [HEX]
  80. SN = Sector Number Register [HEX]
  81. CL = Cylinder Low Register [HEX]
  82. CH = Cylinder High Register [HEX]
  83. DH = Device/Head Register [HEX]
  84. DC = Device Command Register [HEX]
  85. ER = Error register [HEX]
  86. ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 5141 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  92. When the command that caused the error occurred, the device was active or idle.
  93.  
  94. After command completion occurred, registers were:
  95. ER ST SC SN CL CH DH
  96. -- -- -- -- -- -- --
  97. 40 41 d8 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
  98.  
  99. Commands leading to the command that caused the error were:
  100. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  101. -- -- -- -- -- -- -- -- ---------------- --------------------
  102. 60 08 d8 b8 09 00 40 00 01:15:25.177 READ FPDMA QUEUED
  103. ef 10 02 00 00 00 a0 00 01:15:25.174 SET FEATURES [Enable SATA feature]
  104. 27 00 00 00 00 00 e0 00 01:15:25.174 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  105. ec 00 00 00 00 00 a0 00 01:15:25.173 IDENTIFY DEVICE
  106. ef 03 45 00 00 00 a0 00 01:15:25.173 SET FEATURES [Set transfer mode]
  107.  
  108. Error 5140 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  109. When the command that caused the error occurred, the device was active or idle.
  110.  
  111. After command completion occurred, registers were:
  112. ER ST SC SN CL CH DH
  113. -- -- -- -- -- -- --
  114. 40 41 48 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
  115.  
  116. Commands leading to the command that caused the error were:
  117. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  118. -- -- -- -- -- -- -- -- ---------------- --------------------
  119. 60 08 48 b8 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
  120. 60 08 40 b0 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
  121. 60 08 38 a8 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
  122. 60 08 30 a0 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
  123. 60 08 28 98 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
  124.  
  125. Error 5139 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  126. When the command that caused the error occurred, the device was active or idle.
  127.  
  128. After command completion occurred, registers were:
  129. ER ST SC SN CL CH DH
  130. -- -- -- -- -- -- --
  131. 40 41 d8 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
  132.  
  133. Commands leading to the command that caused the error were:
  134. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  135. -- -- -- -- -- -- -- -- ---------------- --------------------
  136. 60 80 d8 80 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
  137. 60 38 d0 40 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
  138. 60 08 c8 10 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
  139. 60 18 c0 20 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
  140. 60 08 b8 78 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
  141.  
  142. Error 5138 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  143. When the command that caused the error occurred, the device was active or idle.
  144.  
  145. After command completion occurred, registers were:
  146. ER ST SC SN CL CH DH
  147. -- -- -- -- -- -- --
  148. 40 41 80 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
  149.  
  150. Commands leading to the command that caused the error were:
  151. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  152. -- -- -- -- -- -- -- -- ---------------- --------------------
  153. 60 08 80 b8 09 00 40 00 01:15:13.052 READ FPDMA QUEUED
  154. 60 20 78 88 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
  155. 60 38 70 48 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
  156. 60 28 68 18 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
  157. 60 10 60 00 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
  158.  
  159. Error 5137 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
  160. When the command that caused the error occurred, the device was active or idle.
  161.  
  162. After command completion occurred, registers were:
  163. ER ST SC SN CL CH DH
  164. -- -- -- -- -- -- --
  165. 40 41 20 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
  166.  
  167. Commands leading to the command that caused the error were:
  168. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  169. -- -- -- -- -- -- -- -- ---------------- --------------------
  170. 60 08 20 b8 09 00 40 00 01:15:09.278 READ FPDMA QUEUED
  171. 60 08 18 b0 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
  172. 60 08 10 a8 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
  173. 60 08 08 a0 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
  174. 60 08 00 98 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
  175.  
  176. SMART Self-test log structure revision number 1
  177. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  178. # 1 Short offline Completed: read failure 00% 7384 133944552
  179. # 2 Extended offline Aborted by host 90% 7384 -
  180. # 3 Short offline Completed without error 00% 7355 -
  181. # 4 Short offline Completed without error 00% 0 -
  182.  
  183. SMART Selective self-test log data structure revision number 1
  184. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  185. 1 0 0 Not_testing
  186. 2 0 0 Not_testing
  187. 3 0 0 Not_testing
  188. 4 0 0 Not_testing
  189. 5 0 0 Not_testing
  190. Selective self-test flags (0x0):
  191. After scanning selected spans, do NOT read-scan remainder of disk.
  192. If Selective self-test is pending on power-up, resume after 0 minute delay.