- ubuntu@ubuntu:~$ sudo smartctl -a /dev/sda
- smartctl 6.5 2016-01-24 r4214 [i686-linux-4.10.0-28-generic] (local build)
- Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Toshiba 2.5" HDD MQ01ABD...
- Device Model: TOSHIBA MQ01ABD100
- Serial Number: 45GPTOLQT
- LU WWN Device Id: 5 000039 631c025f5
- Firmware Version: AX0P2D
- User Capacity: 1,000,204,886,016 bytes [1.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Form Factor: 2.5 inches
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Tue Nov 7 23:02:33 2017 UTC
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x00) Offline data collection activity
- was never started.
- Auto Offline Data Collection: Disabled.
- Self-test execution status: ( 112) The previous self-test completed having
- the read element of the test failed.
- Total time to complete Offline
- data collection: ( 120) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 236) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 128
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 1715
- 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 8
- 9 Power_On_Hours 0x0032 082 082 000 Old_age Always - 7389
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 1390
- 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 103
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 161
- 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 6175
- 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 37 (Min/Max 13/49)
- 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 117266449
- 200 Multi_Zone_Error_Rate 0x0032 100 100 000 Old_age Always - 482623563
- 240 Head_Flying_Hours 0x0032 085 085 000 Old_age Always - 6171
- 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 21288237593
- 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 19796058047
- 254 Free_Fall_Sensor 0x0032 100 100 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 5141 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 5141 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 d8 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 d8 b8 09 00 40 00 01:15:25.177 READ FPDMA QUEUED
- ef 10 02 00 00 00 a0 00 01:15:25.174 SET FEATURES [Enable SATA feature]
- 27 00 00 00 00 00 e0 00 01:15:25.174 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
- ec 00 00 00 00 00 a0 00 01:15:25.173 IDENTIFY DEVICE
- ef 03 45 00 00 00 a0 00 01:15:25.173 SET FEATURES [Set transfer mode]
- Error 5140 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 48 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 48 b8 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
- 60 08 40 b0 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
- 60 08 38 a8 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
- 60 08 30 a0 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
- 60 08 28 98 09 00 40 00 01:15:21.412 READ FPDMA QUEUED
- Error 5139 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 d8 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 80 d8 80 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
- 60 38 d0 40 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
- 60 08 c8 10 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
- 60 18 c0 20 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
- 60 08 b8 78 08 00 40 00 01:15:17.628 READ FPDMA QUEUED
- Error 5138 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 80 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 80 b8 09 00 40 00 01:15:13.052 READ FPDMA QUEUED
- 60 20 78 88 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
- 60 38 70 48 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
- 60 28 68 18 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
- 60 10 60 00 08 00 40 00 01:15:13.052 READ FPDMA QUEUED
- Error 5137 occurred at disk power-on lifetime: 7382 hours (307 days + 14 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 41 20 b8 09 00 40 Error: UNC at LBA = 0x000009b8 = 2488
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 60 08 20 b8 09 00 40 00 01:15:09.278 READ FPDMA QUEUED
- 60 08 18 b0 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
- 60 08 10 a8 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
- 60 08 08 a0 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
- 60 08 00 98 09 00 40 00 01:15:09.277 READ FPDMA QUEUED
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed: read failure 00% 7389 2634504
- # 2 Short offline Completed: read failure 00% 7384 133944552
- # 3 Extended offline Aborted by host 90% 7384 -
- # 4 Short offline Completed without error 00% 7355 -
- # 5 Short offline Completed without error 00% 0 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.