  1. smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-68-generic] (local build)
  2. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Western Digital Caviar Green (AF)
  6. Device Model:     WDC WD20EARS-00MVWB0
  7. Serial Number:    WD-WCAZA5781744
  8. LU WWN Device Id: 5 0014ee 205ad5f1f
  9. Firmware Version: 51.0AB51
  10. User Capacity:    2,000,398,934,016 bytes [2.00 TB]
  11. Sector Size:      512 bytes logical/physical
  12. Device is:        In smartctl database [for details use: -P show]
  13. ATA Version is:   ATA8-ACS (minor revision not indicated)
  14. SATA Version is:  SATA 2.6, 3.0 Gb/s
  15. Local Time is:    Tue Dec  8 11:43:56 2015 EST
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status:  (0x82) Offline data collection activity
  24.                                         was completed without error.
  25.                                         Auto Offline Data Collection: Enabled.
  26. Self-test execution status:      ( 121) The previous self-test completed having
  27.                                         the read element of the test failed.
  28. Total time to complete Offline
  29. data collection:                (39180) seconds.
  30. Offline data collection
  31. capabilities:                    (0x7b) SMART execute Offline immediate.
  32.                                         Auto Offline data collection on/off support.
  33.                                         Suspend Offline collection upon new
  34.                                         command.
  35.                                         Offline surface scan supported.
  36.                                         Self-test supported.
  37.                                         Conveyance Self-test supported.
  38.                                         Selective Self-test supported.
  39. SMART capabilities:            (0x0003) Saves SMART data before entering
  40.                                         power-saving mode.
  41.                                         Supports SMART auto save timer.
  42. Error logging capability:        (0x01) Error logging supported.
  43.                                         General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time:        (   2) minutes.
  46. Extended self-test routine
  47. recommended polling time:        ( 378) minutes.
  48. Conveyance self-test routine
  49. recommended polling time:        (   5) minutes.
  50. SCT capabilities:              (0x3035) SCT Status supported.
  51.                                         SCT Feature Control supported.
  52.                                         SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 16
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  57.   1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       27
  58.   3 Spin_Up_Time            0x0027   228   185   021    Pre-fail  Always       -       3600
  59.   4 Start_Stop_Count        0x0032   096   096   000    Old_age   Always       -       4181
  60.   5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  61.   7 Seek_Error_Rate         0x002e   200   200   000    Old_age   Always       -       0
  62.   9 Power_On_Hours          0x0032   081   081   000    Old_age   Always       -       14209
  63.  10 Spin_Retry_Count        0x0032   100   100   000    Old_age   Always       -       0
  64.  11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
  65.  12 Power_Cycle_Count       0x0032   096   096   000    Old_age   Always       -       4039
  66. 192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       96
  67. 193 Load_Cycle_Count        0x0032   166   166   000    Old_age   Always       -       104374
  68. 194 Temperature_Celsius     0x0022   127   104   000    Old_age   Always       -       23
  69. 196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
  70. 197 Current_Pending_Sector  0x0032   200   200   000    Old_age   Always       -       16
  71. 198 Offline_Uncorrectable   0x0030   200   200   000    Old_age   Offline      -       0
  72. 199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
  73. 200 Multi_Zone_Error_Rate   0x0008   200   200   000    Old_age   Offline      -       9
  74.  
  75. SMART Error Log Version: 1
  76. No Errors Logged
  77.  
  78. SMART Self-test log structure revision number 1
  79. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  80. # 1  Extended offline    Completed: read failure       90%     14209         803512
  81. # 2  Short offline       Completed: read failure       90%     14209         803508
  82. # 3  Extended offline    Completed: read failure       90%     14208         803504
  83. # 4  Short offline       Completed without error       00%        32         -
  84. # 5  Short offline       Completed without error       00%         3         -
  85.  
  86. SMART Selective self-test log data structure revision number 1
  87.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  88.     1        0        0  Not_testing
  89.     2        0        0  Not_testing
  90.     3        0        0  Not_testing
  91.     4        0        0  Not_testing
  92.     5        0        0  Not_testing
  93. Selective self-test flags (0x0):
  94.   After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.