SHARE
TWEET

Untitled

a guest Mar 21st, 2013 166 Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
  1. smartctl 5.40 2010-07-12 r3124 [i686-pc-linux-gnu] (local build)
  2. Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family:     Seagate Barracuda 7200.11 family
  6. Device Model:     ST3500320AS
  7. Serial Number:    9QM26RHK
  8. Firmware Version: SD15
  9. User Capacity:    500,106,780,160 bytes
  10. Device is:        In smartctl database [for details use: -P show]
  11. ATA Version is:   8
  12. ATA Standard is:  ATA-8-ACS revision 4
  13. Local Time is:    Thu Mar 21 14:03:02 2013 CET
  14.  
  15. ==> WARNING: There are known problems with these drives,
  16. AND THIS FIRMWARE VERSION IS AFFECTED,
  17. see the following Seagate web pages:
  18. http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931
  19. http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951
  20.  
  21. SMART support is: Available - device has SMART capability.
  22. SMART support is: Enabled
  23.  
  24. === START OF READ SMART DATA SECTION ===
  25. SMART overall-health self-assessment test result: PASSED
  26. See vendor-specific Attribute list for marginal Attributes.
  27.  
  28. General SMART Values:
  29. Offline data collection status:  (0x82) Offline data collection activity
  30.                                         was completed without error.
  31.                                         Auto Offline Data Collection: Enabled.
  32. Self-test execution status:      (   0) The previous self-test routine completed
  33.                                         without error or no self-test has ever
  34.                                         been run.
  35. Total time to complete Offline
  36. data collection:                 ( 625) seconds.
  37. Offline data collection
  38. capabilities:                    (0x7b) SMART execute Offline immediate.
  39.                                         Auto Offline data collection on/off support.
  40.                                         Suspend Offline collection upon new
  41.                                         command.
  42.                                         Offline surface scan supported.
  43.                                         Self-test supported.
  44.                                         Conveyance Self-test supported.
  45.                                         Selective Self-test supported.
  46. SMART capabilities:            (0x0003) Saves SMART data before entering
  47.                                         power-saving mode.
  48.                                         Supports SMART auto save timer.
  49. Error logging capability:        (0x01) Error logging supported.
  50.                                         General Purpose Logging supported.
  51. Short self-test routine
  52. recommended polling time:        (   1) minutes.
  53. Extended self-test routine
  54. recommended polling time:        ( 116) minutes.
  55. Conveyance self-test routine
  56. recommended polling time:        (   2) minutes.
  57. SCT capabilities:              (0x103b) SCT Status supported.
  58.                                         SCT Error Recovery Control supported.
  59.                                         SCT Feature Control supported.
  60.                                         SCT Data Table supported.
  61.  
  62. SMART Attributes Data Structure revision number: 10
  63. Vendor Specific SMART Attributes with Thresholds:
  64. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  65.   1 Raw_Read_Error_Rate     0x000f   083   081   006    Pre-fail  Always       -       82081378
  66.   3 Spin_Up_Time            0x0003   095   085   000    Pre-fail  Always       -       0
  67.   4 Start_Stop_Count        0x0032   098   098   020    Old_age   Always       -       2682
  68.   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       476
  69.   7 Seek_Error_Rate         0x000f   072   059   030    Pre-fail  Always       -       81886833771
  70.   9 Power_On_Hours          0x0032   058   058   000    Old_age   Always       -       37038
  71.  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       16
  72.  12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       266
  73. 184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
  74. 187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       1261
  75. 188 Command_Timeout         0x0032   100   099   000    Old_age   Always       -       3
  76. 189 High_Fly_Writes         0x003a   097   097   000    Old_age   Always       -       3
  77. 190 Airflow_Temperature_Cel 0x0022   068   044   045    Old_age   Always   In_the_past 32 (0 16 36 26)
  78. 194 Temperature_Celsius     0x0022   032   056   000    Old_age   Always       -       32 (0 21 0 0)
  79. 195 Hardware_ECC_Recovered  0x001a   049   028   000    Old_age   Always       -       82081378
  80. 197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       6
  81. 198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       6
  82. 199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
  83.  
  84. SMART Error Log Version: 1
  85. ATA Error Count: 1261 (device log contains only the most recent five errors)
  86.         CR = Command Register [HEX]
  87.         FR = Features Register [HEX]
  88.         SC = Sector Count Register [HEX]
  89.         SN = Sector Number Register [HEX]
  90.         CL = Cylinder Low Register [HEX]
  91.         CH = Cylinder High Register [HEX]
  92.         DH = Device/Head Register [HEX]
  93.         DC = Device Command Register [HEX]
  94.         ER = Error register [HEX]
  95.         ST = Status register [HEX]
  96. Powered_Up_Time is measured from power on, and printed as
  97. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  98. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  99.  
  100. Error 1261 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  101.   When the command that caused the error occurred, the device was active or idle.
  102.  
  103.   After command completion occurred, registers were:
  104.   ER ST SC SN CL CH DH
  105.   -- -- -- -- -- -- --
  106.   40 51 00 ff ff ff 0f
  107.  
  108.   Commands leading to the command that caused the error were:
  109.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  110.   -- -- -- -- -- -- -- --  ----------------  --------------------
  111.   60 00 08 ff ff ff 4f 00  12d+05:26:19.602  READ FPDMA QUEUED
  112.   27 00 00 00 00 00 e0 00  12d+05:26:19.601  READ NATIVE MAX ADDRESS EXT
  113.   ec 00 00 00 00 00 a0 00  12d+05:26:19.600  IDENTIFY DEVICE
  114.   ef 03 46 00 00 00 a0 00  12d+05:26:19.600  SET FEATURES [Set transfer mode]
  115.   27 00 00 00 00 00 e0 00  12d+05:26:19.600  READ NATIVE MAX ADDRESS EXT
  116.  
  117. Error 1260 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  118.   When the command that caused the error occurred, the device was active or idle.
  119.  
  120.   After command completion occurred, registers were:
  121.   ER ST SC SN CL CH DH
  122.   -- -- -- -- -- -- --
  123.   40 51 00 ff ff ff 0f
  124.  
  125.   Commands leading to the command that caused the error were:
  126.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  127.   -- -- -- -- -- -- -- --  ----------------  --------------------
  128.   60 00 08 ff ff ff 4f 00  12d+05:26:16.428  READ FPDMA QUEUED
  129.   27 00 00 00 00 00 e0 00  12d+05:26:16.428  READ NATIVE MAX ADDRESS EXT
  130.   ec 00 00 00 00 00 a0 00  12d+05:26:16.427  IDENTIFY DEVICE
  131.   ef 03 46 00 00 00 a0 00  12d+05:26:16.427  SET FEATURES [Set transfer mode]
  132.   27 00 00 00 00 00 e0 00  12d+05:26:16.426  READ NATIVE MAX ADDRESS EXT
  133.  
  134. Error 1259 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  135.   When the command that caused the error occurred, the device was active or idle.
  136.  
  137.   After command completion occurred, registers were:
  138.   ER ST SC SN CL CH DH
  139.   -- -- -- -- -- -- --
  140.   40 51 00 ff ff ff 0f
  141.  
  142.   Commands leading to the command that caused the error were:
  143.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  144.   -- -- -- -- -- -- -- --  ----------------  --------------------
  145.   60 00 08 ff ff ff 4f 00  12d+05:26:13.138  READ FPDMA QUEUED
  146.   27 00 00 00 00 00 e0 00  12d+05:26:13.138  READ NATIVE MAX ADDRESS EXT
  147.   ec 00 00 00 00 00 a0 00  12d+05:26:13.137  IDENTIFY DEVICE
  148.   ef 03 46 00 00 00 a0 00  12d+05:26:13.137  SET FEATURES [Set transfer mode]
  149.   27 00 00 00 00 00 e0 00  12d+05:26:13.136  READ NATIVE MAX ADDRESS EXT
  150.  
  151. Error 1258 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  152.   When the command that caused the error occurred, the device was active or idle.
  153.  
  154.   After command completion occurred, registers were:
  155.   ER ST SC SN CL CH DH
  156.   -- -- -- -- -- -- --
  157.   40 51 00 ff ff ff 0f
  158.  
  159.   Commands leading to the command that caused the error were:
  160.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  161.   -- -- -- -- -- -- -- --  ----------------  --------------------
  162.   60 00 08 ff ff ff 4f 00  12d+05:26:09.943  READ FPDMA QUEUED
  163.   60 00 08 83 c8 30 44 00  12d+05:26:09.943  READ FPDMA QUEUED
  164.   60 00 30 93 c8 30 44 00  12d+05:26:09.942  READ FPDMA QUEUED
  165.   60 00 18 1b c9 30 44 00  12d+05:26:09.942  READ FPDMA QUEUED
  166.   60 00 30 c3 c9 30 44 00  12d+05:26:09.942  READ FPDMA QUEUED
  167.  
  168. Error 1257 occurred at disk power-on lifetime: 37038 hours (1543 days + 6 hours)
  169.   When the command that caused the error occurred, the device was active or idle.
  170.  
  171.   After command completion occurred, registers were:
  172.   ER ST SC SN CL CH DH
  173.   -- -- -- -- -- -- --
  174.   40 51 00 ff ff ff 0f
  175.  
  176.   Commands leading to the command that caused the error were:
  177.   CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  178.   -- -- -- -- -- -- -- --  ----------------  --------------------
  179.   60 00 08 e3 ca 30 44 00  12d+05:26:06.912  READ FPDMA QUEUED
  180.   60 00 30 c3 c9 30 44 00  12d+05:26:06.911  READ FPDMA QUEUED
  181.   60 00 18 1b c9 30 44 00  12d+05:26:06.911  READ FPDMA QUEUED
  182.   60 00 30 93 c8 30 44 00  12d+05:26:06.911  READ FPDMA QUEUED
  183.   60 00 08 83 c8 30 44 00  12d+05:26:06.910  READ FPDMA QUEUED
  184.  
  185. SMART Self-test log structure revision number 1
  186. No self-tests have been logged.  [To run self-tests, use: smartctl -t]
  187.  
  188.  
  189. SMART Selective self-test log data structure revision number 1
  190.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  191.     1        0        0  Not_testing
  192.     2        0        0  Not_testing
  193.     3        0        0  Not_testing
  194.     4        0        0  Not_testing
  195.     5        0        0  Not_testing
  196. Selective self-test flags (0x0):
  197.   After scanning selected spans, do NOT read-scan remainder of disk.
  198. If Selective self-test is pending on power-up, resume after 0 minute delay.
RAW Paste Data
We use cookies for various purposes including analytics. By continuing to use Pastebin, you agree to our use of cookies as described in the Cookies Policy. OK, I Understand
 