  1. === START OF INFORMATION SECTION ===
  2. Model Family: Western Digital Blue Mobile
  3. Device Model: WDC WD10SPCX-24HWST1
  4. Serial Number: WD-WX41AA58C7TX
  5. LU WWN Device Id: 5 0014ee 65b93947f
  6. Firmware Version: 02.01A02
  7. User Capacity: 1,000,204,886,016 bytes [1.00 TB]
  8. Sector Sizes: 512 bytes logical, 4096 bytes physical
  9. Rotation Rate: 5400 rpm
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: ACS-2 (minor revision not indicated)
  12. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  13. Local Time is: Wed Oct 23 22:44:34 2019 BST
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status: (0x82) Offline data collection activity
  22. was completed without error.
  23. Auto Offline Data Collection: Enabled.
  24. Self-test execution status: ( 0) The previous self-test routine completed
  25. without error or no self-test has ever
  26. been run.
  27. Total time to complete Offline
  28. data collection: (16380) seconds.
  29. Offline data collection
  30. capabilities: (0x7b) SMART execute Offline immediate.
  31. Auto Offline data collection on/off support.
  32. Suspend Offline collection upon new
  33. command.
  34. Offline surface scan supported.
  35. Self-test supported.
  36. Conveyance Self-test supported.
  37. Selective Self-test supported.
  38. SMART capabilities: (0x0003) Saves SMART data before entering
  39. power-saving mode.
  40. Supports SMART auto save timer.
  41. Error logging capability: (0x01) Error logging supported.
  42. General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time: ( 2) minutes.
  45. Extended self-test routine
  46. recommended polling time: ( 188) minutes.
  47. Conveyance self-test routine
  48. recommended polling time: ( 5) minutes.
  49. SCT capabilities: (0x7035) SCT Status supported.
  50. SCT Feature Control supported.
  51. SCT Data Table supported.
  52.  
  53. SMART Attributes Data Structure revision number: 16
  54. Vendor Specific SMART Attributes with Thresholds:
  55. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  56. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
  57. 3 Spin_Up_Time 0x0027 188 184 021 Pre-fail Always - 1575
  58. 4 Start_Stop_Count 0x0032 034 034 000 Old_age Always - 66870
  59. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  60. 7 Seek_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0
  61. 9 Power_On_Hours 0x0032 084 084 000 Old_age Always - 11888
  62. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  63. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  64. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 233
  65. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 157
  66. 193 Load_Cycle_Count 0x0032 162 162 000 Old_age Always - 116173
  67. 194 Temperature_Celsius 0x0022 102 090 000 Old_age Always - 45
  68. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  69. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  70. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
  71. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 2
  72. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  73. 240 Head_Flying_Hours 0x0032 088 088 000 Old_age Always - 8791
  74.  
  75. SMART Error Log Version: 1
  76. ATA Error Count: 2
  77. CR = Command Register [HEX]
  78. FR = Features Register [HEX]
  79. SC = Sector Count Register [HEX]
  80. SN = Sector Number Register [HEX]
  81. CL = Cylinder Low Register [HEX]
  82. CH = Cylinder High Register [HEX]
  83. DH = Device/Head Register [HEX]
  84. DC = Device Command Register [HEX]
  85. ER = Error register [HEX]
  86. ST = Status register [HEX]
  87. Powered_Up_Time is measured from power on, and printed as
  88. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  89. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  90.  
  91. Error 2 occurred at disk power-on lifetime: 4686 hours (195 days + 6 hours)
  92. When the command that caused the error occurred, the device was active or idle.
  93.  
  94. After command completion occurred, registers were:
  95. ER ST SC SN CL CH DH
  96. -- -- -- -- -- -- --
  97. 04 51 01 00 00 00 00 Error: ABRT
  98.  
  99. Commands leading to the command that caused the error were:
  100. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  101. -- -- -- -- -- -- -- -- ---------------- --------------------
  102. b0 d5 01 e1 4f c2 00 80 1d+05:39:02.258 SMART READ LOG
  103. b0 d5 01 e1 4f c2 00 80 1d+05:39:02.258 SMART READ LOG
  104. b0 d6 01 e0 4f c2 00 80 1d+05:39:02.258 SMART WRITE LOG
  105. b0 d6 01 e0 4f c2 00 80 1d+05:39:02.257 SMART WRITE LOG
  106. b0 d5 01 e0 4f c2 00 80 1d+05:39:02.257 SMART READ LOG
  107.  
  108. Error 1 occurred at disk power-on lifetime: 3507 hours (146 days + 3 hours)
  109. When the command that caused the error occurred, the device was active or idle.
  110.  
  111. After command completion occurred, registers were:
  112. ER ST SC SN CL CH DH
  113. -- -- -- -- -- -- --
  114. 04 51 01 00 00 00 00 Error: ABRT
  115.  
  116. Commands leading to the command that caused the error were:
  117. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  118. -- -- -- -- -- -- -- -- ---------------- --------------------
  119. b0 d5 01 e1 4f c2 00 80 3d+21:14:27.478 SMART READ LOG
  120. b0 d5 01 e1 4f c2 00 80 3d+21:14:27.478 SMART READ LOG
  121. b0 d6 01 e0 4f c2 00 80 3d+21:14:27.477 SMART WRITE LOG
  122. b0 d6 01 e0 4f c2 00 80 3d+21:14:27.477 SMART WRITE LOG
  123. b0 d5 01 e0 4f c2 00 80 3d+21:14:27.476 SMART READ LOG
  124.  
  125. SMART Self-test log structure revision number 1
  126. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  127. # 1 Short offline Completed without error 00% 2056 -
  128. # 2 Short offline Completed without error 00% 1316 -
  129. # 3 Short offline Completed without error 00% 1037 -
  130.  
  131. SMART Selective self-test log data structure revision number 1
  132. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  133. 1 0 0 Not_testing
  134. 2 0 0 Not_testing
  135. 3 0 0 Not_testing
  136. 4 0 0 Not_testing
  137. 5 0 0 Not_testing
  138. Selective self-test flags (0x0):
  139. After scanning selected spans, do NOT read-scan remainder of disk.
  140. If Selective self-test is pending on power-up, resume after 0 minute delay.