  1. # smartctl -a /dev/sdn
  2. smartctl 7.0 2018-12-30 r4883 [x86_64-linux-5.0.21-1-pve] (local build)
  3. Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
  4.  
  5. === START OF INFORMATION SECTION ===
  6. Model Family: Western Digital Re
  7. Device Model: WDC WD4000FYYZ-01UL1B0
  8. Serial Number: WD-WCC130062244
  9. LU WWN Device Id: 5 0014ee 20769f016
  10. Firmware Version: 01.01K01
  11. User Capacity: 4,000,787,030,016 bytes [4.00 TB]
  12. Sector Size: 512 bytes logical/physical
  13. Rotation Rate: 7200 rpm
  14. Device is: In smartctl database [for details use: -P show]
  15. ATA Version is: ATA8-ACS (minor revision not indicated)
  16. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  17. Local Time is: Wed Sep 18 09:34:36 2019 UTC
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: PASSED
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x82) Offline data collection activity
  26. was completed without error.
  27. Auto Offline Data Collection: Enabled.
  28. Self-test execution status: ( 0) The previous self-test routine completed
  29. without error or no self-test has ever
  30. been run.
  31. Total time to complete Offline
  32. data collection: (45360) seconds.
  33. Offline data collection
  34. capabilities: (0x7b) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. Offline surface scan supported.
  39. Self-test supported.
  40. Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 2) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 491) minutes.
  51. Conveyance self-test routine
  52. recommended polling time: ( 5) minutes.
  53. SCT capabilities: (0x70bd) SCT Status supported.
  54. SCT Error Recovery Control supported.
  55. SCT Feature Control supported.
  56. SCT Data Table supported.
  57.  
  58. SMART Attributes Data Structure revision number: 16
  59. Vendor Specific SMART Attributes with Thresholds:
  60. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  61. 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 33
  62. 3 Spin_Up_Time 0x0027 148 139 021 Pre-fail Always - 11566
  63. 4 Start_Stop_Count 0x0032 089 089 000 Old_age Always - 11877
  64. 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
  65. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  66. 9 Power_On_Hours 0x0032 038 038 000 Old_age Always - 45635
  67. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  68. 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  69. 12 Power_Cycle_Count 0x0032 089 089 000 Old_age Always - 11876
  70. 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
  71. 192 Power-Off_Retract_Count 0x0032 185 185 000 Old_age Always - 11865
  72. 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 51
  73. 194 Temperature_Celsius 0x0022 125 093 000 Old_age Always - 27
  74. 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
  75. 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
  76. 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
  77. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  78. 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
  79.  
  80. SMART Error Log Version: 1
  81. No Errors Logged
  82.  
  83. SMART Self-test log structure revision number 1
  84. No self-tests have been logged. [To run self-tests, use: smartctl -t]
  85.  
  86. SMART Selective self-test log data structure revision number 1
  87. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  88. 1 0 0 Not_testing
  89. 2 0 0 Not_testing
  90. 3 0 0 Not_testing
  91. 4 0 0 Not_testing
  92. 5 0 0 Not_testing
  93. Selective self-test flags (0x0):
  94. After scanning selected spans, do NOT read-scan remainder of disk.
  95. If Selective self-test is pending on power-up, resume after 0 minute delay.