Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- energyplus -w ITA_Torino-Caselle.160590_IGDG.epw -r 0_Inverno_single_spes0.idf
- EnergyPlus Starting
- EnergyPlus, Version 8.6.0-198c6a3cff, YMD=2018.12.17 16:37
- Processing Data Dictionary
- Processing Input File
- Initializing Response Factors
- Calculating CTFs for "300MM CONCRETE SLAB", Construction # 3
- Calculating CTFs for "COMBINED FLAT ROOF - ENERGY CODE STANDARD - HEAVYWEIGHT (DATA MODIFIED WHEN LOADED TO FILE)", Construction # 5
- Calculating CTFs for "COMBINED FLAT ROOF - ENERGY CODE STANDARD - HEAVYWEIGHT (DATA MODIFIED WHEN LOADED TO FILE)_REV", Construction # 6
- Calculating CTFs for "115MM SINGLE LEAF BRICK (PLASTERED BOTH SIDES)", Construction # 7
- Calculating CTFs for "COPIA DI WALL - ENERGY CODE STANDARD - HEAVYWEIGHT (DATA MODIFIED WHEN LOADED TO FILE)", Construction # 9
- Initializing Window Optical Properties
- Initializing Solar Calculations
- Allocate Solar Module Arrays
- Initializing Zone Report Variables
- Initializing Surface (Shading) Report Variables
- Computing Interior Solar Absorption Factors
- Determining Shadowing Combinations
- Computing Window Shade Absorption Factors
- Proceeding with Initializing Solar Calculations
- Initializing Surfaces
- Initializing Outdoor environment for Surfaces
- Setting up Surface Reporting Variables
- Initializing Temperature and Flux Histories
- Initializing Window Shading
- Computing Interior Absorption Factors
- Computing Interior Diffuse Solar Absorption Factors
- Computing Interior Diffuse Solar Exchange through Interzone Windows
- Initializing Solar Heat Gains
- Initializing Internal Heat Gains
- Initializing Interior Solar Distribution
- Initializing Interior Convection Coefficients
- Gathering Information for Predefined Reporting
- Completed Initializing Surface Heat Balance
- Calculate Outside Surface Heat Balance
- Calculate Inside Surface Heat Balance
- Calculate Air Heat Balance
- Initializing HVAC
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Performing Zone Sizing Simulation
- ...for Sizing Period: #1 SUMMER DESIGN DAY IN PROVA1 (01-10:31-03) JUN
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Performing Zone Sizing Simulation
- ...for Sizing Period: #2 SUMMER DESIGN DAY IN PROVA1 (01-10:31-03) JUL
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Performing Zone Sizing Simulation
- ...for Sizing Period: #3 SUMMER DESIGN DAY IN PROVA1 (01-10:31-03) AUG
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Performing Zone Sizing Simulation
- ...for Sizing Period: #4 SUMMER DESIGN DAY IN PROVA1 (01-10:31-03) SEP
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Warming up
- Performing Zone Sizing Simulation
- ...for Sizing Period: #5 WINTER DESIGN DAY IN PROVA1 (01-10:31-03)
- Initializing Simulation
- Reporting Surfaces
- Beginning Primary Simulation
- Initializing New Environment Parameters
- Warming up {1}
- Warming up {2}
- Warming up {3}
- Warming up {4}
- Warming up {5}
- Warming up {6}
- Starting Simulation at 10/01 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=10/21
- Continuing Simulation at 10/21 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=11/10
- Continuing Simulation at 11/10 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=11/30
- Continuing Simulation at 11/30 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=12/20
- Continuing Simulation at 12/20 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=01/09
- Continuing Simulation at 01/09 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=01/29
- Continuing Simulation at 01/29 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=02/18
- Continuing Simulation at 02/18 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=03/10
- Continuing Simulation at 03/10 for PROVA1 (01-10:31-03)
- Updating Shadowing Calculations, Start Date=03/30
- Continuing Simulation at 03/30 for PROVA1 (01-10:31-03)
- Writing tabular output file results using comma format.
- Writing tabular output file results using HTML format.
- Writing final SQL reports
- ReadVarsESO program starting.
- ReadVars Run Time=00hr 00min 0.79sec
- ReadVarsESO program completed successfully.
- ReadVarsESO program starting.
- ReadVars Run Time=00hr 00min 0.24sec
- ReadVarsESO program completed successfully.
- EnergyPlus Run Time=00hr 00min 3.52sec