Advertisement
Not a member of Pastebin yet?
Sign Up,
it unlocks many cool features!
- LibreNMS Discovery
- Version info:
- Commit SHA: eca168ea68446936c606d0ed6e29a209e63248eb
- DB Schema: 156
- PHP: 5.5.9-1ubuntu4.19
- MySQL: 5.5.50-0ubuntu0.14.04.1
- RRDTool: 1.4.7
- SNMP: NET-SNMP 5.7.2
- DEBUG!
- SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1]
- DB Schema already up to date.
- SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE '192.168.52.1' ORDER BY device_id DESC]
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '27']
- 192.168.52.1 27 generic SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- Cyberoam cloud partitio
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.21067.2
- | Cyberoam cloud partitio | .1.3.6.1.4.1.21067.2 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ENTITY-MIB::entPhysicalDescr.1]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqn -m FORTINET-FORTISWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/fortinet -t 1 -r 5 udp:HOSTNAME:161 fsSysVersion.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.39165.1.6.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SML-MIB::product-Name.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.674.10895.3000.1.2.100.1.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ENTITY-MIB::entPhysicalMfgName.1]
- Modules status: Global+ OS Device
- #### Load disco module os ####
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- Cyberoam cloud partitio
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.21067.2
- | Cyberoam cloud partitio | .1.3.6.1.4.1.21067.2 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ENTITY-MIB::entPhysicalDescr.1]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqn -m FORTINET-FORTISWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/fortinet -t 1 -r 5 udp:HOSTNAME:161 fsSysVersion.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.39165.1.6.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 SML-MIB::product-Name.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.674.10895.3000.1.2.100.1.0]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ENTITY-MIB::entPhysicalMfgName.1]
- >> Runtime for discovery module 'os': 0.3380 seconds
- #### Unload disco module os ####
- Modules status: Global+ OS Device
- #### Load disco module ports ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ifDescr]
- ifDescr.1 = lo
- ifDescr.2 = ipsec0
- ifDescr.3 = sit0
- ifDescr.4 = ip6tnl0
- ifDescr.5 = PortA
- ifDescr.6 = PortB
- ifDescr.7 = PortC
- ifDescr.8 = imq0
- ifDescr.9 = imq1
- ifDescr.10 = imq2
- ifDescr.11 = imq3
- ifDescr.12 = imq4
- ifDescr.13 = imq5
- ifDescr.14 = imq6
- ifDescr.15 = imq7
- ifDescr.16 = imq8
- ifDescr.17 = imq9
- ifDescr.18 = imq10
- ifDescr.19 = imq11
- ifDescr.20 = imq12
- ifDescr.21 = imq13
- ifDescr.22 = imq14
- ifDescr.23 = imq15
- ifDescr.24 = gre0
- ifDescr.25 = gretap0
- ifDescr.26 = tun0
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ifName]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ifType]
- ifType.1 = softwareLoopback
- ifType.2 = ethernetCsmacd
- ifType.3 = tunnel
- ifType.4 = tunnel
- ifType.5 = ethernetCsmacd
- ifType.6 = ethernetCsmacd
- ifType.7 = ethernetCsmacd
- ifType.8 = other
- ifType.9 = other
- ifType.10 = other
- ifType.11 = other
- ifType.12 = other
- ifType.13 = other
- ifType.14 = other
- ifType.15 = other
- ifType.16 = other
- ifType.17 = other
- ifType.18 = other
- ifType.19 = other
- ifType.20 = other
- ifType.21 = other
- ifType.22 = other
- ifType.23 = other
- ifType.24 = tunnel
- ifType.25 = ethernetCsmacd
- ifType.26 = other
- Array
- (
- [1] => Array
- (
- [ifDescr] => lo
- [ifType] => softwareLoopback
- )
- [2] => Array
- (
- [ifDescr] => ipsec0
- [ifType] => ethernetCsmacd
- )
- [3] => Array
- (
- [ifDescr] => sit0
- [ifType] => tunnel
- )
- [4] => Array
- (
- [ifDescr] => ip6tnl0
- [ifType] => tunnel
- )
- [5] => Array
- (
- [ifDescr] => PortA
- [ifType] => ethernetCsmacd
- )
- [6] => Array
- (
- [ifDescr] => PortB
- [ifType] => ethernetCsmacd
- )
- [7] => Array
- (
- [ifDescr] => PortC
- [ifType] => ethernetCsmacd
- )
- [8] => Array
- (
- [ifDescr] => imq0
- [ifType] => other
- )
- [9] => Array
- (
- [ifDescr] => imq1
- [ifType] => other
- )
- [10] => Array
- (
- [ifDescr] => imq2
- [ifType] => other
- )
- [11] => Array
- (
- [ifDescr] => imq3
- [ifType] => other
- )
- [12] => Array
- (
- [ifDescr] => imq4
- [ifType] => other
- )
- [13] => Array
- (
- [ifDescr] => imq5
- [ifType] => other
- )
- [14] => Array
- (
- [ifDescr] => imq6
- [ifType] => other
- )
- [15] => Array
- (
- [ifDescr] => imq7
- [ifType] => other
- )
- [16] => Array
- (
- [ifDescr] => imq8
- [ifType] => other
- )
- [17] => Array
- (
- [ifDescr] => imq9
- [ifType] => other
- )
- [18] => Array
- (
- [ifDescr] => imq10
- [ifType] => other
- )
- [19] => Array
- (
- [ifDescr] => imq11
- [ifType] => other
- )
- [20] => Array
- (
- [ifDescr] => imq12
- [ifType] => other
- )
- [21] => Array
- (
- [ifDescr] => imq13
- [ifType] => other
- )
- [22] => Array
- (
- [ifDescr] => imq14
- [ifType] => other
- )
- [23] => Array
- (
- [ifDescr] => imq15
- [ifType] => other
- )
- [24] => Array
- (
- [ifDescr] => gre0
- [ifType] => tunnel
- )
- [25] => Array
- (
- [ifDescr] => gretap0
- [ifType] => ethernetCsmacd
- )
- [26] => Array
- (
- [ifDescr] => tun0
- [ifType] => other
- )
- )
- SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '27' ORDER BY port_id]
- ..........................
- >> Runtime for discovery module 'ports': 0.0570 seconds
- #### Unload disco module ports ####
- Modules status: Global+ OS Device
- #### Load disco module ports-stack ####
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '27']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ifStackStatus]
- End of MIB
- >> Runtime for discovery module 'ports-stack': 0.0240 seconds
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entPhysicalEntry]
- End of MIB
- entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entAliasMappingIdentifier]
- End of MIB
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '27']
- >> Runtime for discovery module 'entity-physical': 0.0390 seconds
- #### Unload disco module entity-physical ####
- Modules status: Global+ OS Device
- #### Load disco module processors ####
- Including: /opt/librenms/includes/discovery/processors/adtran-aos.inc.php
- Including: /opt/librenms/includes/discovery/processors/aen.inc.php
- Including: /opt/librenms/includes/discovery/processors/aos-device.inc.php
- Including: /opt/librenms/includes/discovery/processors/avaya-ers.inc.php
- Including: /opt/librenms/includes/discovery/processors/avaya-vsp.inc.php
- Including: /opt/librenms/includes/discovery/processors/binos.inc.php
- Including: /opt/librenms/includes/discovery/processors/binox.inc.php
- Including: /opt/librenms/includes/discovery/processors/calix.inc.php
- Including: /opt/librenms/includes/discovery/processors/cambium.inc.php
- Including: /opt/librenms/includes/discovery/processors/ciscosb.inc.php
- Including: /opt/librenms/includes/discovery/processors/dasan-nos.inc.php
- Including: /opt/librenms/includes/discovery/processors/datacom.inc.php
- Including: /opt/librenms/includes/discovery/processors/dlink.inc.php
- Including: /opt/librenms/includes/discovery/processors/dnos.inc.php
- Including: /opt/librenms/includes/discovery/processors/dsm.inc.php
- Including: /opt/librenms/includes/discovery/processors/edgecos.inc.php
- Including: /opt/librenms/includes/discovery/processors/edgeswitch.inc.php
- Including: /opt/librenms/includes/discovery/processors/extreme.inc.php
- Including: /opt/librenms/includes/discovery/processors/fiberhome.inc.php
- Including: /opt/librenms/includes/discovery/processors/fortigate.inc.php
- Including: /opt/librenms/includes/discovery/processors/fortiswitch.inc.php
- Including: /opt/librenms/includes/discovery/processors/hpblmos.inc.php
- Including: /opt/librenms/includes/discovery/processors/hrdevice.inc.php
- hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrDevice]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrProcessorLoad]
- End of MIB
- Including: /opt/librenms/includes/discovery/processors/infinity.inc.php
- Including: /opt/librenms/includes/discovery/processors/ios.inc.php
- Including: /opt/librenms/includes/discovery/processors/ironware.inc.php
- Including: /opt/librenms/includes/discovery/processors/junos.inc.php
- Including: /opt/librenms/includes/discovery/processors/junose.inc.php
- Including: /opt/librenms/includes/discovery/processors/netonix.inc.php
- Including: /opt/librenms/includes/discovery/processors/netscaler.inc.php
- Including: /opt/librenms/includes/discovery/processors/nos.inc.php
- Including: /opt/librenms/includes/discovery/processors/pbn.inc.php
- Including: /opt/librenms/includes/discovery/processors/powerconnect.inc.php
- Including: /opt/librenms/includes/discovery/processors/procurve.inc.php
- Including: /opt/librenms/includes/discovery/processors/pulse.inc.php
- Including: /opt/librenms/includes/discovery/processors/radlan.inc.php
- Including: /opt/librenms/includes/discovery/processors/riverbed.inc.php
- Including: /opt/librenms/includes/discovery/processors/screenos.inc.php
- Including: /opt/librenms/includes/discovery/processors/serveriron.inc.php
- Including: /opt/librenms/includes/discovery/processors/sgos.inc.php
- Including: /opt/librenms/includes/discovery/processors/sonicwall.inc.php
- Including: /opt/librenms/includes/discovery/processors/unifi.inc.php
- Including: /opt/librenms/includes/discovery/processors/viprinux.inc.php
- Including: /opt/librenms/includes/discovery/processors/vrp.inc.php
- Including: /opt/librenms/includes/discovery/processors/zywall.inc.php
- Including: /opt/librenms/includes/discovery/processors/zyxel.inc.php
- SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '27' AND `processor_type` != 'ucd-old']
- SQL[SELECT * FROM `processors` WHERE `device_id` = '27']
- >> Runtime for discovery module 'processors': 0.0340 seconds
- #### Unload disco module processors ####
- Modules status: Global+ OS Device
- #### Load disco module mempools ####
- Including: /opt/librenms/includes/discovery/mempools/adtran-aos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/aos-device.inc.php
- Including: /opt/librenms/includes/discovery/mempools/avaya-ers.inc.php
- Including: /opt/librenms/includes/discovery/mempools/avaya-vsp.inc.php
- Including: /opt/librenms/includes/discovery/mempools/binos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/binox.inc.php
- Including: /opt/librenms/includes/discovery/mempools/cemp.inc.php
- Including: /opt/librenms/includes/discovery/mempools/ciscowlc.inc.php
- Including: /opt/librenms/includes/discovery/mempools/cmp.inc.php
- SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '27' AND `mempool_type` = 'cemp']
- Including: /opt/librenms/includes/discovery/mempools/dasan-nos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/dnos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/edgeswitch.inc.php
- Including: /opt/librenms/includes/discovery/mempools/extreme.inc.php
- Including: /opt/librenms/includes/discovery/mempools/fiberhome.inc.php
- Including: /opt/librenms/includes/discovery/mempools/fortigate.inc.php
- Including: /opt/librenms/includes/discovery/mempools/fortiswitch.inc.php
- Including: /opt/librenms/includes/discovery/mempools/hp-procurve.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp -t 1 -r 5 udp:HOSTNAME:161 hpLocal]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp -t 1 -r 5 udp:HOSTNAME:161 hpGlobal]
- End of MIB
- Including: /opt/librenms/includes/discovery/mempools/hpblmos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/hrstorage.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrStorageEntry]
- End of MIB
- Including: /opt/librenms/includes/discovery/mempools/infinity.inc.php
- Including: /opt/librenms/includes/discovery/mempools/ironware-dyn.inc.php
- Including: /opt/librenms/includes/discovery/mempools/junos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/netonix.inc.php
- Including: /opt/librenms/includes/discovery/mempools/netscaler.inc.php
- Including: /opt/librenms/includes/discovery/mempools/nos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/nxos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/pbn.inc.php
- Including: /opt/librenms/includes/discovery/mempools/powerconnect-cpu.inc.php
- Including: /opt/librenms/includes/discovery/mempools/pulse.inc.php
- Including: /opt/librenms/includes/discovery/mempools/screenos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/serveriron.inc.php
- Including: /opt/librenms/includes/discovery/mempools/sgos.inc.php
- Including: /opt/librenms/includes/discovery/mempools/sonicwall.inc.php
- Including: /opt/librenms/includes/discovery/mempools/unifi.inc.php
- Including: /opt/librenms/includes/discovery/mempools/vrp.inc.php
- Including: /opt/librenms/includes/discovery/mempools/zywall.inc.php
- SQL[SELECT * FROM `mempools` WHERE `device_id` = '27']
- >> Runtime for discovery module 'mempools': 0.0500 seconds
- #### Unload disco module mempools ####
- Modules status: Global+ OS Device
- #### Load disco module cisco-vrf-lite ####
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '27' ]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-pw ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cef ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-sla ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-otv ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module ipv4-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipAdEntIfIndex]
- End of MIB
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipAdEntNetMask.]
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '27' AND `ifIndex` = '']
- !SQL[SELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '27' AND A.port_id = I.port_id]
- >> Runtime for discovery module 'ipv4-addresses': 0.0320 seconds
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS Device
- #### Load disco module ipv6-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipv6AddrPfxLength]
- End of MIB
- SQL[SELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '27' AND A.port_id = I.port_id]
- >> Runtime for discovery module 'ipv6-addresses': 0.0280 seconds
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS Device Module [ route ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module sensors ####
- Pre-cache: Including: /opt/librenms/includes/discovery/sensors/pre-cache/aos-emu2.inc.php
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m PowerNet-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 emsStatusSysTempUnits.0]
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 emsProbeStatusEntry]
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/apc.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 coolingUnitStatusAnalogEntry]
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/datacom.inc.php
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/junos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/pbn.inc.php
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/poweralert.inc.php
- Including: /opt/librenms/includes/discovery/sensors/pre-cache/vrp.inc.php
- ENTITY-SENSOR: Caching OIDs: entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entPhySensorType]
- End of MIB
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entPhySensorScale]
- End of MIB
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entPhySensorPrecision]
- End of MIB
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 entPhySensorValue]
- End of MIB
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '27' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'ipmi']
- Temperatures: Including: /opt/librenms/includes/discovery/sensors/temperatures/aen.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/akcp.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/aos-device.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/aos-emu2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/areca.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/avaya-ers.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/avtech.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/binos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/binox.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/calix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/cambium.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/canopy.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ceraos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/cimc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/cisco-envmon.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ciscowlc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/cometsystem-p85xx.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/dell.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/dnos-ftos-s-series.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/dnos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/drac.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/edgeswitch.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/equallogic.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/extreme.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/f5.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/fiberhome.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ftos-c-series.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ftos-e-series.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/hpblmos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/hpilo.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/hwg-ste.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/hwg-ste2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/hytera.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ibm-amm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ibmnos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/ironware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/junos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/junose.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/lantronix-slc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/linux.inc.php
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- Including: /opt/librenms/includes/discovery/sensors/temperatures/lm-sensors.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/mgeups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/mimosa.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/netapp.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/netbotz.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/nos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/observernms-custom.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/papouch-tme.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/pbn.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/pcoweb.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/powerconnect.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/powerware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/qnap.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/riverbed.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/routeros.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/saf.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/sentry3.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/sentry4.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/seos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/serveriron.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/sgos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/siklu.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/sub10.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/supermicro.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/vrp.inc.php
- Including: /opt/librenms/includes/discovery/sensors/temperatures/zyxel-ies.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Humidity : Including: /opt/librenms/includes/discovery/sensors/humidity/akcp.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/aos-emu2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/hwg-ste2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/mgeups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/netbotz.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/pcoweb.inc.php
- Including: /opt/librenms/includes/discovery/sensors/humidity/sentry3.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Voltages: Including: /opt/librenms/includes/discovery/sensors/voltages/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/areca.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/ceraos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/drac.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/eatonups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/gamatronicups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/hytera.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/linux.inc.php
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- Including: /opt/librenms/includes/discovery/sensors/voltages/mgeups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/netvision.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/pbn.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/powerware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/routeros.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/saf.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/sentry3.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/siklu.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/sinetica.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/supermicro.inc.php
- Including: /opt/librenms/includes/discovery/sensors/voltages/vrp.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Frequencies: Including: /opt/librenms/includes/discovery/sensors/frequencies/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/eatonups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/linux.inc.php
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- Including: /opt/librenms/includes/discovery/sensors/frequencies/mgeups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/netvision.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/powerware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/raritan.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/frequencies/sinetica.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Runtime: Including: /opt/librenms/includes/discovery/sensors/runtime/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/runtime/dell-ups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/runtime/sinetica.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Current: Including: /opt/librenms/includes/discovery/sensors/current/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/eatonpdu.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/eatonups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/gamatronicups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/junos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/mgeups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/netvision.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/pbn.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/powerware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/raritan.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/routeros.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/sentry3.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/sinetica.inc.php
- Including: /opt/librenms/includes/discovery/sensors/current/vrp.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Power: Including: /opt/librenms/includes/discovery/sensors/power/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/cimc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/ciscosb.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/dell-ups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/extreme.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/hpblmos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/ipoman.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/raritan.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/routeros.inc.php
- Including: /opt/librenms/includes/discovery/sensors/power/sinetica.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Fanspeeds : Including: /opt/librenms/includes/discovery/sensors/fanspeeds/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/areca.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/dell.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/drac.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/equallogic.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/extreme.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/f5.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/ibm-amm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/lmsensors.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/nos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/qnap.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/routeros.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/sgos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/fanspeeds/supermicro.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Battery Charge: Including: /opt/librenms/includes/discovery/sensors/charge/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/charge/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/charge/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/charge/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/charge/sinetica.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Load: Including: /opt/librenms/includes/discovery/sensors/load/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/load/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/load/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/load/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/load/sinetica.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- States: Including: /opt/librenms/includes/discovery/sensors/states/apc.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/asa.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/avtech.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/cisco.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/ddnos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/dell-ups.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/dell.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/drac.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/dsm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/edgeswitch.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/equallogic.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/f5.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/hpblmos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/hwg-ste.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/ibm-amm.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/ironware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/juniper.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/linux.inc.php
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0]
- Including: /opt/librenms/includes/discovery/sensors/states/mimosa.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/netagent2.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/netonix.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/nxos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/pcoweb.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/qnap.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/rfc1628.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/riverbed.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/serveriron.inc.php
- Including: /opt/librenms/includes/discovery/sensors/states/waas.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- dBm: Including: /opt/librenms/includes/discovery/sensors/dbm/comware.inc.php
- Including: /opt/librenms/includes/discovery/sensors/dbm/datacom.inc.php
- Including: /opt/librenms/includes/discovery/sensors/dbm/junos.inc.php
- Including: /opt/librenms/includes/discovery/sensors/dbm/pbn.inc.php
- Including: /opt/librenms/includes/discovery/sensors/dbm/vrp.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Signal: Including: /opt/librenms/includes/discovery/sensors/signal/cambium.inc.php
- Including: /opt/librenms/includes/discovery/sensors/signal/canopy.inc.php
- Including: /opt/librenms/includes/discovery/sensors/signal/routeros.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- Airflow: Including: /opt/librenms/includes/discovery/sensors/airflow/apc.inc.php
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '27' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 0.2140 seconds
- #### Unload disco module sensors ####
- Modules status: Global+ OS Device
- #### Load disco module storage ####
- Including: /opt/librenms/includes/discovery/storage/eql-storage.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic -t 1 -r 5 udp:HOSTNAME:161 EqliscsiVolumeEntry]
- End of MIB
- Including: /opt/librenms/includes/discovery/storage/hrstorage.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrStorageEntry]
- End of MIB
- Including: /opt/librenms/includes/discovery/storage/netapp-storage.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dfEntry]
- End of MIB
- Including: /opt/librenms/includes/discovery/storage/ucd-dsktable.inc.php
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dskTable]
- End of MIB
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '27' AND `storage_type` != 'dsk']
- SQL[SELECT * FROM `storage` WHERE `device_id` = '27']
- >> Runtime for discovery module 'storage': 0.0850 seconds
- #### Unload disco module storage ####
- Modules status: Global+ OS Device
- #### Load disco module hr-device ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrDeviceEntry]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 hrProcessorEntry]
- End of MIB
- Array
- (
- )
- SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '27']
- >> Runtime for discovery module 'hr-device': 0.0280 seconds
- #### Unload disco module hr-device ####
- Modules status: Global+ OS Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 cdpCache]
- End of MIB
- Array
- (
- )
- LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 lldpRemoteSystemsData]
- End of MIB
- End of MIB || End of MIB || || ||
- Array
- (
- )
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dot1dBasePortIfIndex]
- End of MIB
- Array
- (
- )
- OSPF Discovery: enabled
- SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='27']
- SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '27']
- >> Runtime for discovery module 'discovery-protocols': 0.0520 seconds
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS Device
- #### Load disco module arp-table ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
- End of MIB
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 ipNetToMediaPhysAddress]
- End of MIB
- SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='27' AND M.context_name='']
- >> Runtime for discovery module 'arp-table': 0.0320 seconds
- #### Unload disco module arp-table ####
- Modules status: Global- OS Device Module [ discovery-arp ] disabled globally.
- Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module bgp-peers ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.2.1.15.2]
- End of MIB
- No BGP on hostSQL[SELECT * FROM bgpPeers WHERE device_id = '27' AND (context_name = '' OR context_name IS NULL)]
- FIN BGP
- >> Runtime for discovery module 'bgp-peers': 0.0130 seconds
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS Device
- #### Load disco module vlans ####
- SQL[SELECT * FROM `vlans` WHERE `device_id` = '27']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dot1dBasePortIfIndex]
- End of MIB
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dot1qVlanVersionNumber.0]
- >> Runtime for discovery module 'vlans': 0.0350 seconds
- #### Unload disco module vlans ####
- Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module libvirt-vminfo ####
- >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds
- #### Unload disco module libvirt-vminfo ####
- Modules status: Global+ OS Device
- #### Load disco module toner ####
- Checking valid toner ...
- Array
- (
- )
- SQL[SELECT * FROM toner WHERE device_id = '27']
- Array
- (
- )
- >> Runtime for discovery module 'toner': 0.0000 seconds
- #### Unload disco module toner ####
- Modules status: Global+ OS Device
- #### Load disco module ucd-diskio ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 diskIOEntry]
- End of MIB
- Array
- (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '27']
- >> Runtime for discovery module 'ucd-diskio': 0.0130 seconds
- #### Unload disco module ucd-diskio ####
- Modules status: Global+ OS Device
- #### Load disco module services ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 .1.3.6.1.2.1.6.13.1.1.0.0.0.0]
- End of MIB
- >> Runtime for discovery module 'services': 0.0230 seconds
- #### Unload disco module services ####
- Modules status: Global+ OS Device
- #### Load disco module stp ####
- SQL[SELECT * FROM `stp` WHERE `device_id` = '27']
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs -t 1 -r 5 udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
- >> Runtime for discovery module 'stp': 0.0140 seconds
- #### Unload disco module stp ####
- Modules status: Global+ OS Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 9.9890 seconds
- #### Unload disco module ntp ####
- Modules status: Global- OS Device Module [ loadbalancers ] disabled globally.
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '27' AND `attrib_type` = 'poll_mib' ]
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='1.461' WHERE `device_id` = '27']
- Discovered in 1.461 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','192.168.52.1','1485014777.6973','1.481','1','LIBRENMS\n')]
- /opt/librenms/discovery.php 192.168.52.1 2017-01-21 17:06:19 - 1 devices discovered in 1.481 secs
- SNMP: Get[24/0.53s] Walk [31/0.49s]
- MySQL: Cell[6/0.00s] Row[4/0.00s] Rows[39/0.01s] Column[1/0.00s] Update[1/0.00s] Insert[1/0.00s] Delete[0/0.00s]