Untitled

a guest
Mar 10th, 2012
117
0
Never
Not a member of Pastebin yet? Sign Up, it unlocks many cool features!
text 0.87 KB | None | 0 0
  1. linux-base (3) unstable; urgency=low
  2.  
  3. * Some HP Smart Array controllers are now handled by the new 'hpsa'
  4. driver, rather than the 'cciss' driver.
  5.  
  6. While the cciss driver presented disk device names beginning with
  7. 'cciss/', hpsa makes disk arrays appear as ordinary SCSI disks and
  8. presents device names beginning with 'sd'. In a system that already
  9. has other SCSI or SCSI-like devices, names may change unpredictably.
  10.  
  11. During the upgrade from earlier versions, you will be prompted to
  12. update configuration files which refer to device names that may
  13. change. You can choose to do this yourself or to follow an automatic
  14. upgrade process. All changed configuration files are backed up with
  15. a suffix of '.old' (or '^old' in one case).
  16.  
  17. -- Ben Hutchings <ben@decadent.org.uk> Wed, 16 Mar 2011 13:19:34 +0000