smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.11
Device Model: ST31500341AS
Firmware Version: SD1B
User Capacity: 1,500,300,828,160 bytes [1.50 TB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 4
Local Time is: Sat May 19 17:58:05 2012 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 609) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 255) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x103b) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 118 099 006 Pre-fail Always - 199688128
3 Spin_Up_Time 0x0003 094 092 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 92
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 12
7 Seek_Error_Rate 0x000f 080 060 030 Pre-fail Always - 103383097
9 Power_On_Hours 0x0032 066 066 000 Old_age Always - 29924
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 1
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 93
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 098 098 000 Old_age Always - 2
188 Command_Timeout 0x0032 100 099 000 Old_age Always - 17180131332
189 High_Fly_Writes 0x003a 001 001 000 Old_age Always - 429
190 Airflow_Temperature_Cel 0x0022 058 045 045 Old_age Always In_the_past 42 (Min/Max 39/48)
194 Temperature_Celsius 0x0022 042 055 000 Old_age Always - 42 (0 18 0 0 0)
195 Hardware_ECC_Recovered 0x001a 034 019 000 Old_age Always - 199688128
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 3
SMART Error Log Version: 1
ATA Error Count: 2
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 occurred at disk power-on lifetime: 21305 hours (887 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 30 ff ff ff 4f 00 3d+20:22:57.707 READ FPDMA QUEUED
60 00 30 ff ff ff 4f 00 3d+20:22:57.699 READ FPDMA QUEUED
60 00 50 ff ff ff 4f 00 3d+20:22:57.685 READ FPDMA QUEUED
ef 03 46 00 00 00 00 00 3d+20:22:57.675 SET FEATURES [Set transfer mode]
ef 03 0c 00 00 00 00 00 3d+20:22:57.665 SET FEATURES [Set transfer mode]
Error 1 occurred at disk power-on lifetime: 21305 hours (887 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 30 ff ff ff 4f 00 3d+20:22:54.133 READ FPDMA QUEUED
60 00 50 ff ff ff 4f 00 3d+20:22:54.133 READ FPDMA QUEUED
60 00 30 ff ff ff 4f 00 3d+20:22:54.133 READ FPDMA QUEUED
60 00 50 ff ff ff 4f 00 3d+20:22:54.132 READ FPDMA QUEUED
60 00 30 ff ff ff 4f 00 3d+20:22:54.131 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 29910 -
# 2 Short offline Completed without error 00% 29906 -
# 3 Conveyance offline Completed without error 00% 29906 -
# 4 Extended offline Completed without error 00% 29744 -
# 5 Conveyance offline Completed without error 00% 29740 -
# 6 Short offline Completed without error 00% 29739 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.