  1. smartctl 6.3 2014-07-26 r3976 [FreeBSD 9.3-RELEASE-p28 amd64] (local build)
  2. Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Toshiba 3.5" MD04ACA... Enterprise HDD
  6. Device Model: TOSHIBA MD04ACA400
  7. Serial Number: X5EE***
  8. LU WWN Device Id: 5 000039 69bd817ca
  9. Firmware Version: FP2A
  10. User Capacity: 4,000,787,030,016 bytes [4.00 TB]
  11. Sector Sizes: 512 bytes logical, 4096 bytes physical
  12. Rotation Rate: 7200 rpm
  13. Form Factor: 3.5 inches
  14. Device is: In smartctl database [for details use: -P show]
  15. ATA Version is: ATA8-ACS (minor revision not indicated)
  16. SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
  17. Local Time is: Mon Dec 21 07:19:15 2015 CET
  18. SMART support is: Available - device has SMART capability.
  19. SMART support is: Enabled
  20.  
  21. === START OF READ SMART DATA SECTION ===
  22. SMART overall-health self-assessment test result: PASSED
  23.  
  24. General SMART Values:
  25. Offline data collection status: (0x82) Offline data collection activity
  26. was completed without error.
  27. Auto Offline Data Collection: Enabled.
  28. Self-test execution status: ( 0) The previous self-test routine completed
  29. without error or no self-test has ever
  30. been run.
  31. Total time to complete Offline
  32. data collection: ( 120) seconds.
  33. Offline data collection
  34. capabilities: (0x5b) SMART execute Offline immediate.
  35. Auto Offline data collection on/off support.
  36. Suspend Offline collection upon new
  37. command.
  38. Offline surface scan supported.
  39. Self-test supported.
  40. No Conveyance Self-test supported.
  41. Selective Self-test supported.
  42. SMART capabilities: (0x0003) Saves SMART data before entering
  43. power-saving mode.
  44. Supports SMART auto save timer.
  45. Error logging capability: (0x01) Error logging supported.
  46. General Purpose Logging supported.
  47. Short self-test routine
  48. recommended polling time: ( 2) minutes.
  49. Extended self-test routine
  50. recommended polling time: ( 480) minutes.
  51. SCT capabilities: (0x003d) SCT Status supported.
  52. SCT Error Recovery Control supported.
  53. SCT Feature Control supported.
  54. SCT Data Table supported.
  55.  
  56. SMART Attributes Data Structure revision number: 16
  57. Vendor Specific SMART Attributes with Thresholds:
  58. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  59. 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  60. 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0
  61. 3 Spin_Up_Time 0x0027 100 100 001 Pre-fail Always - 7082
  62. 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3
  63. 5 Reallocated_Sector_Ct 0x0033 100 100 050 Pre-fail Always - 32
  64. 7 Seek_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0
  65. 8 Seek_Time_Performance 0x0005 100 100 050 Pre-fail Offline - 0
  66. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 124
  67. 10 Spin_Retry_Count 0x0033 100 100 030 Pre-fail Always - 0
  68. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3
  69. 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 5
  70. 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1
  71. 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 5
  72. 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 34 (Min/Max 21/37)
  73. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 4
  74. 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0
  75. 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
  76. 199 UDMA_CRC_Error_Count 0x0032 200 253 000 Old_age Always - 0
  77. 220 Disk_Shift 0x0002 100 100 000 Old_age Always - 0
  78. 222 Loaded_Hours 0x0032 100 100 000 Old_age Always - 124
  79. 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  80. 224 Load_Friction 0x0022 100 100 000 Old_age Always - 0
  81. 226 Load-in_Time 0x0026 100 100 000 Old_age Always - 210
  82. 240 Head_Flying_Hours 0x0001 100 100 001 Pre-fail Offline - 0
  83.  
  84. SMART Error Log Version: 1
  85. No Errors Logged
  86.  
  87. SMART Self-test log structure revision number 1
  88. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  89. # 1 Extended offline Completed without error 00% 118 -
  90. # 2 Short offline Completed without error 00% 99 -
  91. # 3 Short offline Completed without error 00% 75 -
  92. # 4 Short offline Completed without error 00% 51 -
  93. # 5 Short offline Completed without error 00% 27 -
  94. # 6 Short offline Completed without error 00% 7 -
  95.  
  96. SMART Selective self-test log data structure revision number 1
  97. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  98. 1 0 0 Not_testing
  99. 2 0 0 Not_testing
  100. 3 0 0 Not_testing
  101. 4 0 0 Not_testing
  102. 5 0 0 Not_testing
  103. Selective self-test flags (0x0):
  104. After scanning selected spans, do NOT read-scan remainder of disk.
  105. If Selective self-test is pending on power-up, resume after 0 minute delay.