  1. sudo smartctl -a /dev/sda
  2. [sudo] password for annakamilla-escr:
  3. Sinto muito, tente novamente.
  4. [sudo] password for annakamilla-escr:
  5. smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.16.0-53-generic] (local build)
  6. Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
  7.  
  8. === START OF INFORMATION SECTION ===
  9. Device Model:     SanDisk SDSSDP128G
  10. Serial Number:    152230400649
  11. LU WWN Device Id: 5 001b44 e7d388e89
  12. Firmware Version: 3.2.0
  13. User Capacity:    126.035.288.064 bytes [126 GB]
  14. Sector Size:      512 bytes logical/physical
  15. Rotation Rate:    Solid State Device
  16. Device is:        Not in smartctl database [for details use: -P showall]
  17. ATA Version is:   ACS-2 T13/2015-D revision 3
  18. SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
  19. Local Time is:    Thu Nov 19 23:17:52 2015 BRST
  20. SMART support is: Available - device has SMART capability.
  21. SMART support is: Enabled
  22.  
  23. === START OF READ SMART DATA SECTION ===
  24. SMART overall-health self-assessment test result: PASSED
  25.  
  26. General SMART Values:
  27. Offline data collection status:  (0x00) Offline data collection activity
  28.                     was never started.
  29.                     Auto Offline Data Collection: Disabled.
  30. Self-test execution status:      (   0) The previous self-test routine completed
  31.                     without error or no self-test has ever
  32.                     been run.
  33. Total time to complete Offline
  34. data collection:        (  120) seconds.
  35. Offline data collection
  36. capabilities:            (0x51) SMART execute Offline immediate.
  37.                     No Auto Offline data collection support.
  38.                     Suspend Offline collection upon new
  39.                     command.
  40.                     No Offline surface scan supported.
  41.                     Self-test supported.
  42.                     No Conveyance Self-test supported.
  43.                     Selective Self-test supported.
  44. SMART capabilities:            (0x0003) Saves SMART data before entering
  45.                     power-saving mode.
  46.                     Supports SMART auto save timer.
  47. Error logging capability:        (0x01) Error logging supported.
  48.                     General Purpose Logging supported.
  49. Short self-test routine
  50. recommended polling time:    (   2) minutes.
  51. Extended self-test routine
  52. recommended polling time:    (  21) minutes.
  53.  
  54. SMART Attributes Data Structure revision number: 1
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  57.   5 Reallocated_Sector_Ct   0x0002   100   100   000    Old_age   Always       -       0
  58.   9 Power_On_Hours          0x0002   100   100   000    Old_age   Always       -       92
  59.  12 Power_Cycle_Count       0x0002   100   100   000    Old_age   Always       -       25
  60. 165 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       2259
  61. 171 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       0
  62. 172 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       0
  63. 173 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       0
  64. 174 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       7
  65. 187 Reported_Uncorrect      0x0002   100   100   000    Old_age   Always       -       0
  66. 194 Temperature_Celsius     0x0022   058   042   000    Old_age   Always       -       42 (Min/Max 13/47)
  67. 230 Unknown_SSD_Attribute   0x0002   100   100   000    Old_age   Always       -       0
  68. 232 Available_Reservd_Space 0x0003   100   100   005    Pre-fail  Always       -       0
  69. 234 Unknown_Attribute       0x0002   100   100   000    Old_age   Always       -       4
  70. 241 Total_LBAs_Written      0x0002   100   100   000    Old_age   Always       -       148197475
  71. 242 Total_LBAs_Read         0x0002   100   100   000    Old_age   Always       -       94980809
  72.  
  73. SMART Error Log Version: 1
  74. No Errors Logged
  75.  
  76. SMART Self-test log structure revision number 1
  77. Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
  78. # 1  Short offline       Completed without error       00%        89         -
  79. # 2  Extended offline    Aborted by host               90%        89         -
  80. # 3  Short offline       Completed without error       00%        64         -
  81. # 4  Short offline       Completed without error       00%        32         -
  82.  
  83. SMART Selective self-test log data structure revision number 1
  84.  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
  85.     1        0        0  Not_testing
  86.     2        0        0  Not_testing
  87.     3        0        0  Not_testing
  88.     4        0        0  Not_testing
  89.     5        0        0  Not_testing
  90. Selective self-test flags (0x0):
  91.   After scanning selected spans, do NOT read-scan remainder of disk.
  92. If Selective self-test is pending on power-up, resume after 0 minute delay.