  1. smartctl version 5.38 [powerpc-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen
  2. Home page is http://smartmontools.sourceforge.net/
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Device Model: WDC WD20EARS-00MVWB0
  6. Serial Number: WD-WCAZA6826124
  7. Firmware Version: 51.0AB51
  8. User Capacity: 2,000,398,934,016 bytes
  9. Device is: Not in smartctl database [for details use: -P showall]
  10. ATA Version is: 8
  11. ATA Standard is: Exact ATA specification draft version not indicated
  12. Local Time is: Mon Aug 20 13:00:28 2012 CEST
  13. SMART support is: Available - device has SMART capability.
  14. SMART support is: Enabled
  15.  
  16. === START OF READ SMART DATA SECTION ===
  17. SMART overall-health self-assessment test result: PASSED
  18.  
  19. General SMART Values:
  20. Offline data collection status: (0x84) Offline data collection activity
  21. was suspended by an interrupting command from host.
  22. Auto Offline Data Collection: Enabled.
  23. Self-test execution status: ( 0) The previous self-test routine completed
  24. without error or no self-test has ever
  25. been run.
  26. Total time to complete Offline
  27. data collection: (36660) seconds.
  28. Offline data collection
  29. capabilities: (0x7b) SMART execute Offline immediate.
  30. Auto Offline data collection on/off support.
  31. Suspend Offline collection upon new
  32. command.
  33. Offline surface scan supported.
  34. Self-test supported.
  35. Conveyance Self-test supported.
  36. Selective Self-test supported.
  37. SMART capabilities: (0x0003) Saves SMART data before entering
  38. power-saving mode.
  39. Supports SMART auto save timer.
  40. Error logging capability: (0x01) Error logging supported.
  41. General Purpose Logging supported.
  42. Short self-test routine
  43. recommended polling time: ( 2) minutes.
  44. Extended self-test routine
  45. recommended polling time: ( 255) minutes.
  46. Conveyance self-test routine
  47. recommended polling time: ( 5) minutes.
  48. SCT capabilities: (0x3035) SCT Status supported.
  49. SCT Feature Control supported.
  50. SCT Data Table supported.
  51.  
  52. SMART Attributes Data Structure revision number: 16
  53. Vendor Specific SMART Attributes with Thresholds:
  54. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  55. 1 Raw_Read_Error_Rate 0x002f 199 199 051 Pre-fail Always - 3075
  56. 3 Spin_Up_Time 0x0027 253 166 021 Pre-fail Always - 1025
  57. 4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3276
  58. 5 Reallocated_Sector_Ct 0x0033 197 197 140 Pre-fail Always - 74
  59. 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
  60. 9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 9316
  61. 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
  62. 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
  63. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 29
  64. 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 27
  65. 193 Load_Cycle_Count 0x0032 102 102 000 Old_age Always - 296706
  66. 194 Temperature_Celsius 0x0022 087 077 000 Old_age Always - 63
  67. 196 Reallocated_Event_Count 0x0032 150 150 000 Old_age Always - 50
  68. 197 Current_Pending_Sector 0x0032 200 001 000 Old_age Always - 197
  69. 198 Offline_Uncorrectable 0x0030 199 199 000 Old_age Offline - 399
  70. 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
  71. 200 Multi_Zone_Error_Rate 0x0008 191 191 000 Old_age Offline - 2635
  72.  
  73. SMART Error Log Version: 1
  74. ATA Error Count: 1
  75. CR = Command Register [HEX]
  76. FR = Features Register [HEX]
  77. SC = Sector Count Register [HEX]
  78. SN = Sector Number Register [HEX]
  79. CL = Cylinder Low Register [HEX]
  80. CH = Cylinder High Register [HEX]
  81. DH = Device/Head Register [HEX]
  82. DC = Device Command Register [HEX]
  83. ER = Error register [HEX]
  84. ST = Status register [HEX]
  85. Powered_Up_Time is measured from power on, and printed as
  86. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  87. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  88.  
  89. Error 1 occurred at disk power-on lifetime: 8968 hours (373 days + 16 hours)
  90. When the command that caused the error occurred, the device was active or idle.
  91.  
  92. After command completion occurred, registers were:
  93. ER ST SC SN CL CH DH
  94. -- -- -- -- -- -- --
  95. 40 51 80 80 b7 2b e8 Error: UNC 128 sectors at LBA = 0x082bb780 = 137082752
  96.  
  97. Commands leading to the command that caused the error were:
  98. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  99. -- -- -- -- -- -- -- -- ---------------- --------------------
  100. c8 00 80 80 b7 2b e8 08 10d+02:50:06.249 READ DMA
  101. c8 00 08 00 47 3a e0 08 10d+02:50:06.247 READ DMA
  102. c8 00 08 f8 46 3a e0 08 10d+02:50:06.247 READ DMA
  103. c8 00 08 f0 46 3a e0 08 10d+02:50:06.247 READ DMA
  104. c8 00 08 e8 46 3a e0 08 10d+02:50:06.246 READ DMA
  105.  
  106. SMART Self-test log structure revision number 1
  107. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  108. # 1 Short offline Interrupted (host reset) 10% 9181 -
  109. # 2 Short offline Completed without error 00% 9155 -
  110. # 3 Extended offline Aborted by host 90% 9102 -
  111. # 4 Short offline Completed: read failure 10% 9102 627458432
  112. # 5 Short offline Completed: read failure 90% 9101 210134350
  113. # 6 Short offline Completed: read failure 10% 9100 561043375
  114. # 7 Short offline Completed: read failure 90% 9100 210134345
  115. # 8 Short offline Completed: read failure 80% 9099 506789655
  116. # 9 Short offline Completed: read failure 10% 9099 622959985
  117. #10 Short offline Completed without error 00% 9098 -
  118. #11 Short offline Completed: read failure 10% 9098 622959985
  119. #12 Short offline Completed: read failure 10% 9098 627549899
  120. #13 Short offline Completed: read failure 10% 9088 627549870
  121. #14 Short offline Completed without error 00% 9088 -
  122. #15 Extended offline Completed: read failure 90% 9073 210134344
  123. #16 Short offline Aborted by host 90% 9073 -
  124. #17 Short offline Aborted by host 90% 9073 -
  125. #18 Short offline Interrupted (host reset) 50% 9073 -
  126. #19 Short offline Aborted by host 80% 9073 -
  127. #20 Short offline Completed without error 00% 49 -
  128. #21 Short offline Aborted by host 90% 1 -
  129.  
  130. SMART Selective self-test log data structure revision number 1
  131. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  132. 1 0 0 Not_testing
  133. 2 0 0 Not_testing
  134. 3 0 0 Not_testing
  135. 4 0 0 Not_testing
  136. 5 0 0 Not_testing
  137. Selective self-test flags (0x0):
  138. After scanning selected spans, do NOT read-scan remainder of disk.
  139. If Selective self-test is pending on power-up, resume after 0 minute delay.