- smartctl 5.41 2011-06-09 r3365 [x86_64-linux-3.2.0-29-generic] (local build)
- Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
- === START OF INFORMATION SECTION ===
- Model Family: Hitachi Deskstar 7K3000
- Device Model: Hitachi HDS723020BLA642
- Serial Number: MN1220F31VUB3D
- LU WWN Device Id: 5 000cca 369da4858
- Firmware Version: MN6OA5C0
- User Capacity: 2,000,398,934,016 bytes [2.00 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: 8
- ATA Standard is: ATA-8-ACS revision 4
- Local Time is: Fri Jan 25 19:08:04 2013 EST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (19381) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 255) minutes.
- SCT capabilities: (0x003d) SCT Status supported.
- SCT Error Recovery Control supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0
- 2 Throughput_Performance 0x0005 133 133 054 Pre-fail Offline - 90
- 3 Spin_Up_Time 0x0007 160 160 024 Pre-fail Always - 361 (Average 355)
- 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 44
- 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
- 8 Seek_Time_Performance 0x0005 130 130 020 Pre-fail Offline - 28
- 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 4233
- 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 44
- 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 145
- 193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 145
- 194 Temperature_Celsius 0x0002 157 157 000 Old_age Always - 38 (Min/Max 21/73)
- 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- No self-tests have been logged. [To run self-tests, use: smartctl -t]
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.