  1. smartctl 5.43 2012-06-30 r3573 [i686-linux-3.5.0-27-generic] (local build)
  2. Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Fujitsu MJA BH
  6. Device Model: FUJITSU MJA2250BH G2
  7. Serial Number: K96QTA22AK2H
  8. LU WWN Device Id: 5 00000e 044498b70
  9. Firmware Version: 0084001C
  10. User Capacity: 250,059,350,016 bytes [250 GB]
  11. Sector Size: 512 bytes logical/physical
  12. Device is: In smartctl database [for details use: -P show]
  13. ATA Version is: 8
  14. ATA Standard is: ATA-8-ACS revision 3f
  15. Local Time is: Wed Apr 17 22:58:41 2013 CEST
  16. SMART support is: Available - device has SMART capability.
  17. SMART support is: Enabled
  18.  
  19. === START OF READ SMART DATA SECTION ===
  20. SMART overall-health self-assessment test result: PASSED
  21.  
  22. General SMART Values:
  23. Offline data collection status: (0x00) Offline data collection activity
  24. was never started.
  25. Auto Offline Data Collection: Disabled.
  26. Self-test execution status: ( 121) The previous self-test completed having
  27. the read element of the test failed.
  28. Total time to complete Offline
  29. data collection: ( 783) seconds.
  30. Offline data collection
  31. capabilities: (0x7b) SMART execute Offline immediate.
  32. Auto Offline data collection on/off support.
  33. Suspend Offline collection upon new
  34. command.
  35. Offline surface scan supported.
  36. Self-test supported.
  37. Conveyance Self-test supported.
  38. Selective Self-test supported.
  39. SMART capabilities: (0x0003) Saves SMART data before entering
  40. power-saving mode.
  41. Supports SMART auto save timer.
  42. Error logging capability: (0x01) Error logging supported.
  43. General Purpose Logging supported.
  44. Short self-test routine
  45. recommended polling time: ( 2) minutes.
  46. Extended self-test routine
  47. recommended polling time: ( 111) minutes.
  48. Conveyance self-test routine
  49. recommended polling time: ( 2) minutes.
  50. SCT capabilities: (0x003d) SCT Status supported.
  51. SCT Error Recovery Control supported.
  52. SCT Feature Control supported.
  53. SCT Data Table supported.
  54.  
  55. SMART Attributes Data Structure revision number: 16
  56. Vendor Specific SMART Attributes with Thresholds:
  57. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  58. 1 Raw_Read_Error_Rate 0x000f 100 051 046 Pre-fail Always - 186986
  59. 2 Throughput_Performance 0x0005 100 100 030 Pre-fail Offline - 34537472
  60. 3 Spin_Up_Time 0x0003 100 100 025 Pre-fail Always - 0
  61. 4 Start_Stop_Count 0x0032 099 099 000 Old_age Always - 3109
  62. 5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail Always - 1 (1999 1)
  63. 7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 2879
  64. 8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0
  65. 9 Power_On_Hours 0x0032 090 090 000 Old_age Always - 5261
  66. 10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0
  67. 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3109
  68. 192 Power-Off_Retract_Count 0x0032 098 098 000 Old_age Always - 506
  69. 193 Load_Cycle_Count 0x0032 098 098 000 Old_age Always - 44002
  70. 194 Temperature_Celsius 0x0022 100 055 000 Old_age Always - 50 (Min/Max 11/69)
  71. 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 44364
  72. 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 (3 15089)
  73. 197 Current_Pending_Sector 0x0012 001 001 000 Old_age Always - 256
  74. 198 Offline_Uncorrectable 0x0010 001 001 000 Old_age Offline - 283
  75. 199 UDMA_CRC_Error_Count 0x003e 200 253 000 Old_age Always - 0
  76. 200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always - 31884
  77. 203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 429563576730
  78. 240 Head_Flying_Hours 0x003e 200 200 000 Old_age Always - 0
  79.  
  80. SMART Error Log Version: 1
  81. ATA Error Count: 2314 (device log contains only the most recent five errors)
  82. CR = Command Register [HEX]
  83. FR = Features Register [HEX]
  84. SC = Sector Count Register [HEX]
  85. SN = Sector Number Register [HEX]
  86. CL = Cylinder Low Register [HEX]
  87. CH = Cylinder High Register [HEX]
  88. DH = Device/Head Register [HEX]
  89. DC = Device Command Register [HEX]
  90. ER = Error register [HEX]
  91. ST = Status register [HEX]
  92. Powered_Up_Time is measured from power on, and printed as
  93. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  94. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  95.  
  96. Error 2314 occurred at disk power-on lifetime: 5261 hours (219 days + 5 hours)
  97. When the command that caused the error occurred, the device was active or idle.
  98.  
  99. After command completion occurred, registers were:
  100. ER ST SC SN CL CH DH
  101. -- -- -- -- -- -- --
  102. 40 41 03 02 c7 52 40 Error: UNC at LBA = 0x0052c702 = 5424898
  103.  
  104. Commands leading to the command that caused the error were:
  105. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  106. -- -- -- -- -- -- -- -- ---------------- --------------------
  107. 60 08 00 00 c7 52 40 08 03:44:04.865 READ FPDMA QUEUED
  108. 60 08 00 f8 c6 52 40 08 03:44:03.777 READ FPDMA QUEUED
  109. 60 08 00 f0 c6 52 40 08 03:44:03.776 READ FPDMA QUEUED
  110. 60 08 00 e8 c6 52 40 08 03:44:03.755 READ FPDMA QUEUED
  111. 60 08 00 e0 c6 52 40 08 03:44:03.755 READ FPDMA QUEUED
  112.  
  113. Error 2313 occurred at disk power-on lifetime: 5261 hours (219 days + 5 hours)
  114. When the command that caused the error occurred, the device was active or idle.
  115.  
  116. After command completion occurred, registers were:
  117. ER ST SC SN CL CH DH
  118. -- -- -- -- -- -- --
  119. 40 41 03 ca 7f 52 40 Error: UNC at LBA = 0x00527fca = 5406666
  120.  
  121. Commands leading to the command that caused the error were:
  122. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  123. -- -- -- -- -- -- -- -- ---------------- --------------------
  124. 60 08 00 c8 7f 52 40 08 03:43:51.774 READ FPDMA QUEUED
  125. 60 08 00 c0 7f 52 40 08 03:43:47.629 READ FPDMA QUEUED
  126. 60 08 00 b8 7f 52 40 08 03:43:47.451 READ FPDMA QUEUED
  127. 60 08 00 b0 7f 52 40 08 03:43:46.162 READ FPDMA QUEUED
  128. 60 08 00 a8 7f 52 40 08 03:43:45.607 READ FPDMA QUEUED
  129.  
  130. Error 2312 occurred at disk power-on lifetime: 5261 hours (219 days + 5 hours)
  131. When the command that caused the error occurred, the device was active or idle.
  132.  
  133. After command completion occurred, registers were:
  134. ER ST SC SN CL CH DH
  135. -- -- -- -- -- -- --
  136. 40 41 03 a2 7f 52 40 Error: UNC at LBA = 0x00527fa2 = 5406626
  137.  
  138. Commands leading to the command that caused the error were:
  139. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  140. -- -- -- -- -- -- -- -- ---------------- --------------------
  141. 60 08 00 a0 7f 52 40 08 03:43:41.272 READ FPDMA QUEUED
  142. 60 08 00 98 7f 52 40 08 03:43:40.407 READ FPDMA QUEUED
  143. ef 10 02 00 00 00 a0 08 03:43:40.405 SET FEATURES [Reserved for Serial ATA]
  144. 27 00 00 00 00 00 e0 08 03:43:40.405 READ NATIVE MAX ADDRESS EXT
  145. ec 00 00 00 00 00 a0 08 03:43:40.403 IDENTIFY DEVICE
  146.  
  147. Error 2311 occurred at disk power-on lifetime: 5261 hours (219 days + 5 hours)
  148. When the command that caused the error occurred, the device was active or idle.
  149.  
  150. After command completion occurred, registers were:
  151. ER ST SC SN CL CH DH
  152. -- -- -- -- -- -- --
  153. 40 41 03 94 7f 52 40 Error: UNC at LBA = 0x00527f94 = 5406612
  154.  
  155. Commands leading to the command that caused the error were:
  156. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  157. -- -- -- -- -- -- -- -- ---------------- --------------------
  158. 60 08 00 90 7f 52 40 08 03:43:33.415 READ FPDMA QUEUED
  159. 60 08 00 88 7f 52 40 08 03:43:31.415 READ FPDMA QUEUED
  160. 60 08 00 80 7f 52 40 08 03:43:30.538 READ FPDMA QUEUED
  161. ef 10 02 00 00 00 a0 08 03:43:30.537 SET FEATURES [Reserved for Serial ATA]
  162. 27 00 00 00 00 00 e0 08 03:43:30.537 READ NATIVE MAX ADDRESS EXT
  163.  
  164. Error 2310 occurred at disk power-on lifetime: 5261 hours (219 days + 5 hours)
  165. When the command that caused the error occurred, the device was active or idle.
  166.  
  167. After command completion occurred, registers were:
  168. ER ST SC SN CL CH DH
  169. -- -- -- -- -- -- --
  170. 40 41 03 7a 7f 52 40 Error: UNC at LBA = 0x00527f7a = 5406586
  171.  
  172. Commands leading to the command that caused the error were:
  173. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  174. -- -- -- -- -- -- -- -- ---------------- --------------------
  175. 60 08 00 78 7f 52 40 08 03:43:26.102 READ FPDMA QUEUED
  176. 60 08 00 70 7f 52 40 08 03:43:25.547 READ FPDMA QUEUED
  177. 60 08 00 68 7f 52 40 08 03:43:22.281 READ FPDMA QUEUED
  178. ef 10 02 00 00 00 a0 08 03:43:22.280 SET FEATURES [Reserved for Serial ATA]
  179. 27 00 00 00 00 00 e0 08 03:43:22.280 READ NATIVE MAX ADDRESS EXT
  180.  
  181. SMART Self-test log structure revision number 1
  182. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  183. # 1 Short offline Completed: read failure 90% 5261 89292706
  184. # 2 Short offline Completed: read failure 90% 5261 89292692
  185. # 3 Extended offline Completed: read failure 90% 5261 89292692
  186. # 4 Short offline Completed: read failure 90% 5261 89292692
  187. # 5 Extended offline Completed: read failure 90% 5259 85359375
  188. # 6 Short offline Completed: read failure 90% 5259 85359375
  189. # 7 Short offline Completed: read failure 90% 5259 85359375
  190. # 8 Short offline Completed: read failure 90% 5259 85359375
  191.  
  192. SMART Selective self-test log data structure revision number 1
  193. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  194. 1 0 0 Not_testing
  195. 2 0 0 Not_testing
  196. 3 0 0 Not_testing
  197. 4 0 0 Not_testing
  198. 5 0 0 Not_testing
  199. Selective self-test flags (0x0):
  200. After scanning selected spans, do NOT read-scan remainder of disk.
  201. If Selective self-test is pending on power-up, resume after 0 minute delay.