  1. smartctl 5.42 2011-10-20 r3458 [i386-pc-solaris2.11] (local build)
  2. Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
  3.  
  4. === START OF INFORMATION SECTION ===
  5. Model Family: Seagate Barracuda 7200.11
  6. Device Model: ST31500341AS
  7. Firmware Version: CC1H
  8. User Capacity: 1,500,301,910,016 bytes [1.50 TB]
  9. Sector Size: 512 bytes logical/physical
  10. Device is: In smartctl database [for details use: -P show]
  11. ATA Version is: 8
  12. ATA Standard is: ATA-8-ACS revision 4
  13. Local Time is: Sat May 19 17:56:37 2012 PDT
  14. SMART support is: Available - device has SMART capability.
  15. SMART support is: Enabled
  16.  
  17. === START OF READ SMART DATA SECTION ===
  18. SMART overall-health self-assessment test result: PASSED
  19.  
  20. General SMART Values:
  21. Offline data collection status: (0x82) Offline data collection activity
  22. was completed without error.
  23. Auto Offline Data Collection: Enabled.
  24. Self-test execution status: ( 0) The previous self-test routine completed
  25. without error or no self-test has ever
  26. been run.
  27. Total time to complete Offline
  28. data collection: ( 625) seconds.
  29. Offline data collection
  30. capabilities: (0x7b) SMART execute Offline immediate.
  31. Auto Offline data collection on/off support.
  32. Suspend Offline collection upon new
  33. command.
  34. Offline surface scan supported.
  35. Self-test supported.
  36. Conveyance Self-test supported.
  37. Selective Self-test supported.
  38. SMART capabilities: (0x0003) Saves SMART data before entering
  39. power-saving mode.
  40. Supports SMART auto save timer.
  41. Error logging capability: (0x01) Error logging supported.
  42. General Purpose Logging supported.
  43. Short self-test routine
  44. recommended polling time: ( 1) minutes.
  45. Extended self-test routine
  46. recommended polling time: ( 255) minutes.
  47. Conveyance self-test routine
  48. recommended polling time: ( 2) minutes.
  49. SCT capabilities: (0x103f) SCT Status supported.
  50. SCT Error Recovery Control supported.
  51. SCT Feature Control supported.
  52. SCT Data Table supported.
  53.  
  54. SMART Attributes Data Structure revision number: 10
  55. Vendor Specific SMART Attributes with Thresholds:
  56. ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
  57. 1 Raw_Read_Error_Rate 0x000f 115 091 006 Pre-fail Always - 91902527
  58. 3 Spin_Up_Time 0x0003 100 100 000 Pre-fail Always - 0
  59. 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 8
  60. 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 22
  61. 7 Seek_Error_Rate 0x000f 061 060 030 Pre-fail Always - 1340955
  62. 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 428
  63. 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
  64. 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 8
  65. 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
  66. 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 227
  67. 188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
  68. 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0
  69. 190 Airflow_Temperature_Cel 0x0022 062 057 045 Old_age Always - 38 (Min/Max 32/43)
  70. 194 Temperature_Celsius 0x0022 038 043 000 Old_age Always - 38 (0 21 0 0 0)
  71. 195 Hardware_ECC_Recovered 0x001a 031 030 000 Old_age Always - 91902527
  72. 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
  73. 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
  74. 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
  75. 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 186324271235500
  76. 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2313148706
  77. 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1107931434
  78.  
  79. SMART Error Log Version: 1
  80. ATA Error Count: 212 (device log contains only the most recent five errors)
  81. CR = Command Register [HEX]
  82. FR = Features Register [HEX]
  83. SC = Sector Count Register [HEX]
  84. SN = Sector Number Register [HEX]
  85. CL = Cylinder Low Register [HEX]
  86. CH = Cylinder High Register [HEX]
  87. DH = Device/Head Register [HEX]
  88. DC = Device Command Register [HEX]
  89. ER = Error register [HEX]
  90. ST = Status register [HEX]
  91. Powered_Up_Time is measured from power on, and printed as
  92. DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
  93. SS=sec, and sss=millisec. It "wraps" after 49.710 days.
  94.  
  95. Error 212 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
  96. When the command that caused the error occurred, the device was active or idle.
  97.  
  98. After command completion occurred, registers were:
  99. ER ST SC SN CL CH DH
  100. -- -- -- -- -- -- --
  101. 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
  102.  
  103. Commands leading to the command that caused the error were:
  104. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  105. -- -- -- -- -- -- -- -- ---------------- --------------------
  106. 60 00 00 95 c0 2d 40 00 2d+02:44:56.392 READ FPDMA QUEUED
  107. 2f 00 01 10 00 00 00 00 2d+02:44:56.313 READ LOG EXT
  108. 00 00 00 00 00 00 00 04 2d+02:44:56.263 NOP [Abort queued commands]
  109. 60 00 00 95 c0 2d 40 00 2d+02:44:53.452 READ FPDMA QUEUED
  110. 2f 00 01 10 00 00 00 00 2d+02:44:53.401 READ LOG EXT
  111.  
  112. Error 211 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
  113. When the command that caused the error occurred, the device was active or idle.
  114.  
  115. After command completion occurred, registers were:
  116. ER ST SC SN CL CH DH
  117. -- -- -- -- -- -- --
  118. 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
  119.  
  120. Commands leading to the command that caused the error were:
  121. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  122. -- -- -- -- -- -- -- -- ---------------- --------------------
  123. 60 00 00 95 c0 2d 40 00 2d+02:44:53.452 READ FPDMA QUEUED
  124. 2f 00 01 10 00 00 00 00 2d+02:44:53.401 READ LOG EXT
  125. 00 00 00 00 00 00 00 04 2d+02:44:53.331 NOP [Abort queued commands]
  126. 60 00 00 95 c0 2d 40 00 2d+02:44:50.553 READ FPDMA QUEUED
  127. 2f 00 01 10 00 00 00 00 2d+02:44:50.474 READ LOG EXT
  128.  
  129. Error 210 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
  130. When the command that caused the error occurred, the device was active or idle.
  131.  
  132. After command completion occurred, registers were:
  133. ER ST SC SN CL CH DH
  134. -- -- -- -- -- -- --
  135. 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
  136.  
  137. Commands leading to the command that caused the error were:
  138. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  139. -- -- -- -- -- -- -- -- ---------------- --------------------
  140. 60 00 00 95 c0 2d 40 00 2d+02:44:50.553 READ FPDMA QUEUED
  141. 2f 00 01 10 00 00 00 00 2d+02:44:50.474 READ LOG EXT
  142. 00 00 00 00 00 00 00 04 2d+02:44:50.424 NOP [Abort queued commands]
  143. 60 00 00 95 c0 2d 40 00 2d+02:44:47.632 READ FPDMA QUEUED
  144. 2f 00 01 10 00 00 00 00 2d+02:44:47.609 READ LOG EXT
  145.  
  146. Error 209 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
  147. When the command that caused the error occurred, the device was active or idle.
  148.  
  149. After command completion occurred, registers were:
  150. ER ST SC SN CL CH DH
  151. -- -- -- -- -- -- --
  152. 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
  153.  
  154. Commands leading to the command that caused the error were:
  155. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  156. -- -- -- -- -- -- -- -- ---------------- --------------------
  157. 60 00 00 95 c0 2d 40 00 2d+02:44:47.632 READ FPDMA QUEUED
  158. 2f 00 01 10 00 00 00 00 2d+02:44:47.609 READ LOG EXT
  159. 00 00 00 00 00 00 00 04 2d+02:44:47.459 NOP [Abort queued commands]
  160. 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
  161. 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
  162.  
  163. Error 208 occurred at disk power-on lifetime: 64 hours (2 days + 16 hours)
  164. When the command that caused the error occurred, the device was active or idle.
  165.  
  166. After command completion occurred, registers were:
  167. ER ST SC SN CL CH DH
  168. -- -- -- -- -- -- --
  169. 40 51 00 f0 c0 2d 00 Error: UNC at LBA = 0x002dc0f0 = 2998512
  170.  
  171. Commands leading to the command that caused the error were:
  172. CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
  173. -- -- -- -- -- -- -- -- ---------------- --------------------
  174. 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
  175. 60 00 10 ff ff ff 4f 00 2d+02:44:44.666 READ FPDMA QUEUED
  176. 61 00 10 10 03 00 40 00 2d+02:44:44.660 WRITE FPDMA QUEUED
  177. 60 00 10 10 03 00 40 00 2d+02:44:44.608 READ FPDMA QUEUED
  178. 61 00 15 b9 69 04 42 00 2d+02:44:44.608 WRITE FPDMA QUEUED
  179.  
  180. SMART Self-test log structure revision number 1
  181. Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
  182. # 1 Extended offline Completed without error 00% 414 -
  183. # 2 Short offline Completed without error 00% 410 -
  184. # 3 Conveyance offline Completed without error 00% 410 -
  185. # 4 Extended offline Completed without error 00% 409 -
  186. # 5 Short offline Completed without error 00% 404 -
  187. # 6 Extended offline Completed: read failure 90% 244 2998512
  188. # 7 Conveyance offline Completed: read failure 90% 244 2998512
  189. # 8 Short offline Completed: read failure 90% 243 2998512
  190. # 9 Conveyance offline Completed: read failure 90% 237 2998512
  191. #10 Conveyance offline Completed: read failure 90% 237 2998512
  192. #11 Conveyance offline Completed: read failure 90% 237 2998512
  193. #12 Extended offline Completed: read failure 90% 237 2998512
  194. #13 Extended offline Completed: read failure 90% 237 2998512
  195. #14 Extended offline Completed: read failure 90% 237 2998512
  196. #15 Extended offline Completed: read failure 90% 237 2998512
  197. #16 Short offline Completed: read failure 90% 237 2998512
  198. #17 Extended offline Completed: read failure 90% 237 2998512
  199. #18 Short offline Completed: read failure 90% 237 2998512
  200. #19 Conveyance offline Completed: read failure 90% 234 2998512
  201. #20 Short offline Completed: read failure 90% 231 2998512
  202. 15 of 15 failed self-tests are outdated by newer successful extended offline self-test # 1
  203.  
  204. SMART Selective self-test log data structure revision number 1
  205. SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
  206. 1 0 0 Not_testing
  207. 2 0 0 Not_testing
  208. 3 0 0 Not_testing
  209. 4 0 0 Not_testing
  210. 5 0 0 Not_testing
  211. Selective self-test flags (0x0):
  212. After scanning selected spans, do NOT read-scan remainder of disk.
  213. If Selective self-test is pending on power-up, resume after 0 minute delay.